Conference Proceeding
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (210) (remove)
Language
- English (210) (remove)
Document Type
- Conference Proceeding (210) (remove)
Keywords
- Biosensor (25)
- CAD (7)
- Finite-Elemente-Methode (7)
- civil engineering (7)
- Bauingenieurwesen (6)
- Clusterion (4)
- Limit analysis (4)
- Natural language processing (4)
- Air purification (3)
- Einspielen <Werkstoff> (3)
- Hämoglobin (3)
- Luftreiniger (3)
- Plasmacluster ion technology (3)
- Raumluft (3)
- Shakedown analysis (3)
- Sonde (3)
- shakedown analysis (3)
- Bruchmechanik (2)
- Clustering (2)
- Eisschicht (2)
- Erythrozyt (2)
- FEM (2)
- Information extraction (2)
- Kohlenstofffaser (2)
- Lipopolysaccharide (2)
- Shakedown (2)
- Stickstoffmonoxid (2)
- biosensor (2)
- celldrum technology (2)
- limit analysis (2)
- lipopolysaccharides (2)
- nitric oxide gas (2)
- 3-nitrofluoranthene (1)
- Active learning (1)
- Adsorption (1)
- Agent-based simulation (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomose (1)
- Anastomosis (1)
- Autofluoreszenzverfahren (1)
- BTEX compounds (1)
- Bakterien (1)
- Bio-Sensors (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Biophoton (1)
- Biosensorik (1)
- Blitzschutz (1)
- CAD ; (1)
- CO (1)
- Chance constrained programming (1)
- Cloud Computing (1)
- Cloud Service Broker (1)
- Conducing polymer (1)
- Dattel (1)
- Deep learning (1)
- Dekontamination (1)
- ECT (1)
- EEG (1)
- EPN (1)
- Einspiel-Analyse (1)
- Einspielanalyse (1)
- Elastodynamik (1)
- Elektrodynamik (1)
- Endothelzelle (1)
- Energy market design (1)
- Evolution of damage (1)
- Exact Ilyushin yield surface (1)
- Extension fracture (1)
- Extension strain criterion (1)
- Festkörper (1)
- Fibroblast (1)
- Finite element method (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fluorescence (1)
- Force (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Grid Computing (1)
- Gunn diode (1)
- Heavy metal detection (1)
- High throughput experimentation (1)
- Hotplate (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Hydrogen sensor (1)
- I3S 2005 (1)
- ISFET (1)
- Impedance Spectroscopy (1)
- Information Extraction (1)
- International Symposium on Sensor Science (1)
- Iterative learning control (1)
- Knee (1)
- Körpertemperatur (1)
- LED chip (1)
- Level sensor (1)
- Lichtstreuungsbasierte Instrumente (1)
- Load modeling (1)
- MEMS (1)
- Machine learning (1)
- Main sensitivity (1)
- Market modeling (1)
- Mechanische Beanspruchung (1)
- Microreactors (1)
- Mohr–Coulomb criterion (1)
- Multi-dimensional wave propagation (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanoparticles (1)
- Nanopartikel (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Natriumhypochlorit (1)
- Natural Language Processing (1)
- Natural language understanding (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Organophosphorus (1)
- Ostazine Orange (1)
- PFM (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Phenylalanine determination (1)
- Potentiometry (1)
- Process model (1)
- Profile Extraction (1)
- Profile extraction (1)
- Proteine (1)
- Pseudomonas putida (1)
- Quartz crystal nanobalance (QCN) (1)
- Quartz micro balances (1)
- Query learning (1)
- Random variable (1)
- Ratcheting (1)
- Reaction-diffusion (1)
- Relation classification (1)
- Reliability of structures (1)
- Reproducible research (1)
- Sensitivity (1)
- Sepsis (1)
- Sleep EEG (1)
- Solid amalgam electrodes (1)
- Stochastic programming (1)
- Supraleiter (1)
- Technische Mechanik (1)
- Text Mining (1)
- Text mining (1)
- Tin oxide (1)
- Tobacco mosaic virus (1)
- Traglast (1)
- Traglastanalyse (1)
- Training (1)
- Trustworthy artificial intelligence (1)
- UML (1)
- Unified Modeling Language (1)
- Wafer (1)
- Wasserbrücke (1)
- Wasserstoffperoxid (1)
- Wellen (1)
- Workflow (1)
- Workflow Orchestration (1)
- acetoin (1)
- activated nanostructured carbon (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- ammonia gas sensors (1)
- amperometric sensor (1)
- antimony doped tin oxide (1)
- autofluorescence-based detection system (1)
- biopotential electrodes (1)
- capacitive field-effect biosensor (1)
- capillary micro-droplet cell (1)
- carcinogens (1)
- catalytic decomposition (1)
- chemical reduction method (1)
- contractile tension (1)
- cross sensitivity (1)
- cytosolic water diffusion (1)
- date palm tree (1)
- design-by-analysis (1)
- doped metal oxide (1)
- doped silicon (1)
- doping (1)
- electrical capacitance tomography (1)
- electro-migration (1)
- electronic noses dendronized polymers inverted mesa technology (1)
- enzymatic methods (1)
- enzyme immobilisation (1)
- enzyme immobilization (1)
- fenitrothion (1)
- finite element analysis (1)
- fluidic (1)
- gas sensor (1)
- gas sensor array (1)
- heater metallisation (1)
- hemoglobin (1)
- hemoglobin dynamics (1)
- high-temperature stability (1)
- humidity (1)
- hydrogel (1)
- hydrogen peroxide (1)
- image sensor (1)
- imaging (1)
- impedance spectroscopy (1)
- ion-selective electrodes (1)
- kontraktile Spannung (1)
- lab-on-a-chip (1)
- lab-on-chip (1)
- layer expansion (1)
- lenslet array (1)
- light scattering analysis (1)
- lightning flash (1)
- limit and shakedown analysis (1)
- limit load (1)
- linear kinematic hardening (1)
- lower bound theorem (1)
- magnetic particles (1)
- material shakedown (1)
- matrix method (1)
- mechanical waves (1)
- metal oxide (1)
- microreactor (1)
- microwave generation (1)
- modeling biosensor (1)
- modelling (1)
- modified electrode (1)
- multi-interface measurement (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- nitrogen oxides (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- organic PVC membranes (1)
- pH-based biosensing (1)
- pattern-size reduction (1)
- plant scanner (1)
- plasma generated ions (1)
- polymer composites (1)
- porous Pt electrode (1)
- principal component (1)
- probabilistic fracture mechanics (1)
- protein (1)
- quantum charging (1)
- ratchetting (1)
- reliability (1)
- rhAPC (1)
- screen-printing (1)
- second-order reliability method (1)
- self-aligned patterning (1)
- sensing properties (1)
- sensors (1)
- shakedown (1)
- sterilisation (1)
- subsurface ice research (1)
- subsurface probe (1)
- surface modification (1)
- swift heavy ions (1)
- thick-film technology (1)
- thin-film microsensors (1)
- voltammetry (1)
- wafer-level testing (1)
- water bridge phenomenon (1)
An H2O2 sensor for the application in industrial sterilisation processes has been developed. Therefore, automated sterilisation equipment at laboratory scale has been constructed using parts from industrial sterilisation facilities. In addition, a software tool has been developed for the control of the sterilisation equipment at laboratory scale. First measurements with the developed sensor set-up as part of the sterilisation equipment have been performed and the sensor has been physically characterised by optical microscopy and SEM.
The workflow of a high throughput screening setup for the rapid identification of new and improved sensor materials is presented. The polyol method was applied to prepare nanoparticular metal oxides as base materials, which were functionalised by surface doping. Using multi-electrode substrates and high throughput impedance spectroscopy (HT-IS) a wide range of materials could be screened in a short time. Applying HT-IS in search of new selective gas sensing materials a NO2-tolerant NO sensing material with reduced sensitivities towards other test gases was identified based on iridium doped zinc oxide. Analogous behaviour was observed for iridium doped indium oxide.
A solid-state amperometric hydrogen sensor based on a protonated Nafion membrane and catalytic active electrode operating at room temperature was fabricated and tested. Ionic conducting polymer-metal electrode interfaces were prepared chemically by using the impregnation-reduction method. The polymer membrane was impregnated with tetra-ammine platinum chloride hydrate and the metal ions were subsequently reduced by using either sodium tetrahydroborate or potassium tetrahydroborate. The hydrogen sensing characteristics with air as reference gas is reported. The sensors were capable of detecting hydrogen concentrations from 10 ppm to 10% in nitrogen. The response time was in the range of 10-30 s and a stable linear current output was observed. The thin Pt films were characterized by XRD, Infrared Spectroscopy, Optical Microscopy, Atomic Force Microscopy, Scanning Electron Microscopy and EDAX.
A multi-sensor system is a chemical sensor system which quantitatively and qualitatively records gases with a combination of cross-sensitive gas sensor arrays and pattern recognition software. This paper addresses the issue of data analysis for identification of gases in a gas sensor array. We introduce a software tool for gas sensor array configuration and simulation. It concerns thereby about a modular software package for the acquisition of data of different sensors. A signal evaluation algorithm referred to as matrix method was used specifically for the software tool. This matrix method computes the gas concentrations from the signals of a sensor array. The software tool was used for the simulation of an array of five sensors to determine gas concentration of CH4, NH3, H2, CO and C2H5OH. The results of the present simulated sensor array indicate that the software tool is capable of the following: (a) identify a gas independently of its concentration; (b) estimate the concentration of the gas, even if the system was not previously exposed to this concentration; (c) tell when a gas concentration exceeds a certain value. A gas sensor data base was build for the configuration of the software. With the data base one can create, generate and manage scenarios and source files for the simulation. With the gas sensor data base and the simulation software an on-line Web-based version was developed, with which the user can configure and simulate sensor arrays on-line.
Study of swift heavy ion modified conduction polymer composites for application as gas sensor
(2006)
A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas.
Functional testing and characterisation of ISFETs on wafer level by means of a micro-droplet cell
(2006)
A wafer-level functionality testing and characterisation system for ISFETs (ionsensitive field-effect transistor) is realised by means of integration of a specifically designed capillary electrochemical micro-droplet cell into a commercial wafer prober-station. The developed system allows the identification and selection of “good” ISFETs at the earliest stage and to avoid expensive bonding, encapsulation and packaging processes for nonfunctioning ISFETs and thus, to decrease costs, which are wasted for bad dies. The developed system is also feasible for wafer-level characterisation of ISFETs in terms of sensitivity, hysteresis and response time. Additionally, the system might be also utilised for wafer-level testing of further electrochemical sensors.
This paper presents the direct route to Design by Analysis (DBA) of the new European pressure vessel standard in the language of limit and shakedown analysis (LISA). This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for some examples from the DBA-Manual. One observation from the examples is, that the optimisation approach gives reliable and close lower bound solutions leading to simple and optimised design decision.
Safety and reliability of structures may be assessed indirectly by stress distributions. Limit and shakedown theorems are simplified but exact methods of plasticity that provide safety factors directly in the loading space. These theorems may be used for a direct definition of the limit state function for failure by plastic collapse or by inadaptation. In a FEM formulation the limit state function is obtained from a nonlinear optimization problem. This direct approach reduces considerably the necessary knowledge of uncertain technological input data, the computing time, and the numerical error. Moreover, the direct way leads to highly effective and precise reliability analyses. The theorems are implemented into a general purpose FEM program in a way capable of large-scale analysis.
Structural design analyses are conducted with the aim of verifying the exclusion of ratcheting. To this end it is important to make a clear distinction between the shakedown range and the ratcheting range. In cyclic plasticity more sophisticated hardening models have been suggested in order to model the strain evolution observed in ratcheting experiments. The hardening models used in shakedown analysis are comparatively simple. It is shown that shakedown analysis can make quite stable predictions of admissible load ranges despite the simplicity of the underlying hardening models. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis. Both give identical or similar shakedown ranges. Structural shakedown analyses show that the loading may have a more pronounced effect than the hardening model.