Refine
Year of publication
Institute
- INB - Institut für Nano- und Biotechnologien (616) (remove)
Language
- English (557)
- German (58)
- Multiple languages (1)
Document Type
- Article (538)
- Conference Proceeding (55)
- Part of a Book (9)
- Doctoral Thesis (4)
- Book (3)
- Patent (3)
- Other (2)
- Report (2)
Keywords
Chalcogenide glass materials as membranes for potentiometric sensors for chemical analysis in solutions have been studied since more than 20 years. In this work, an electrolyte–insulator–semiconductor structure was combined with chalcogenide glass membranes prepared by means of the pulsed laser deposition technique. Depending on the membrane composition a selectivity to different ions (Cd2+ and Pb2+) is achieved. The different sensor membranes have been physically characterised using microscopy, ellipsometry, profilometry, atomic force microscopy (AFM), scanning electron microscopy (SEM) and Rutherford backscattering spectrometry (RBS). The electrochemical behaviour has been investigated via capacitance/voltage (C/V) and constant capacitance (ConCap) measurements and results in a Cd2+ sensitivity of 23.1 ± 0.6 mV per decade in a linear range from 7 × 10−6 to 10−2 mol/l and 24.4 ± 0.5 mV per decade in a linear range from 5 × 10−6 to 10−2 mol/l for Pb2+, respectively.
A light-addressable potentiometric sensor (LAPS) can measure the concentration of one or several analytes at the sensor surface simultaneously in a spatially resolved manner. A modulated light pointer stimulates the semiconductor structure at the area of interest and a responding photocurrent can be read out. By simultaneous stimulation of several areas with light pointers of different modulation frequencies, the read out can be performed at the same time. With the new proposed controller electronic based on a field-programmable gate array (FPGA), it is possible to control the modulation frequencies, phase shifts, and light brightness of multiple light pointers independently and simultaneously. Thus, it is possible to investigate the frequency response of the sensor, and to examine the analyte concentration by the determination of the surface potential with the help of current/voltage curves and phase/voltage curves. Additionally, the ability to individually change the light intensities of each light pointer is used to perform signal correction.
Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface.