Refine
Year of publication
- 2019 (198) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (65)
- IfB - Institut für Bioengineering (41)
- Fachbereich Luft- und Raumfahrttechnik (38)
- Fachbereich Elektrotechnik und Informationstechnik (30)
- INB - Institut für Nano- und Biotechnologien (20)
- Fachbereich Energietechnik (19)
- Fachbereich Maschinenbau und Mechatronik (17)
- Fachbereich Chemie und Biotechnologie (11)
- Fachbereich Bauingenieurwesen (8)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (8)
Language
- English (198) (remove)
Document Type
- Article (97)
- Conference Proceeding (76)
- Part of a Book (15)
- Book (4)
- Doctoral Thesis (3)
- Conference: Meeting Abstract (2)
- Talk (1)
Keywords
- Enterprise Architecture (2)
- Seismic design (2)
- Achilles tendon (1)
- Advanced driver assistance systems (ADAS/AD) (1)
- Aircraft design (1)
- Analytics (1)
- Architectural gear ratio (1)
- Assistive technology (1)
- Automatic control (1)
- BEV (1)
- Case Study (1)
- Change Management (1)
- Combustion (1)
- Components (1)
- Corporate Culture (1)
- Correlations (1)
- Decentral (1)
- Design examples (1)
- Design rules (1)
- Digital Age (1)
- Diversity Management (1)
- Drag (1)
- Earthquake (1)
- Emilia-Romagna earthquake (1)
- Empirical consequence curves (1)
- Empirical fragility functions (1)
- Engineering (1)
- Engineering optimization (1)
- Eurocode 8 (1)
- Force (1)
- Gearbox (1)
- Geometry (1)
- Goodness-of-fit test (1)
- Graph Theory (1)
- Green aircraft (1)
- Gust wind response (1)
- Human-Computer interaction (1)
- Hybrid-electric aircraft (1)
- Hydrogen (1)
- ISO 26262 (1)
- In-plane (1)
- Industrial units (1)
- Innovation Management (1)
- Isolation (1)
- Iterative learning control (1)
- Knee (1)
- Load modeling (1)
- Low NOx (1)
- Low emission (1)
- Machine learning (1)
- Mechanical (1)
- Mixed-integer nonlinear black-box optimization (1)
- Multi-sample problem (1)
- On-site (1)
- Optimization (1)
- Out-of-plane (1)
- PBEE (1)
- Parametric bootstrap (1)
- Powertrain (1)
- Pre-treatment (1)
- Precast buildings (1)
- Preface (1)
- Product family optimization (1)
- Pushover analysis (1)
- Rehabilitation engineering (1)
- Resilience Assessment (1)
- Response spectrum (1)
- Robotic Process Automation (1)
- Running (1)
- Safety of the intended functionality (SOTIF) (1)
- Safety-critical systems validation (1)
- Seismic (1)
- Silos (1)
- Software Robots (1)
- Spectral analysis (1)
- Statistics (1)
- Stiffness (1)
- Tanks (1)
- Tendon properties (1)
- Training (1)
- Unmanned Air Vehicle (1)
- Volume of confidence regions (1)
- WLTP (1)
- Water Supply System (1)
- Wind turbulence (1)
- asymptotic relative efficiency (1)
- batch reproducibility (1)
- concentrating collector (1)
- environmental correlation (1)
- fluorescent protein carrier (1)
- frequency mixing magnetic detection (1)
- greenhouse cultivation (1)
- likelihood ratio test (1)
- magnetic actuation (1)
- magnetic sandwich immunoassay (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- multinomial distribution (1)
- multiparametric immunoassays (1)
- multivariate normal distribution (1)
- plant molecular farming (1)
- point-focussing system (1)
- raytracing (1)
- responsive space (1)
- small solar system body characterisation (1)
- small spacecraft asteroid lander (1)
- small spacecraft solar sail (1)
- solar process heat (1)
- superparamagnetic bead (1)
- system engineering (1)
Thermal and Optical Study on the Frequency Dependence of an Atmospheric Microwave Argon Plasma Jet
(2019)
Clearance of blood components and fluid drainage play a crucial role in subarachnoid hemorrhage (SAH) and post hemorrhagic hydrocephalus (PHH). With the involvement of interstitial fluid (ISF) and cerebrospinal fluid (CSF), two pathways for the clearance of fluid and solutes in the brain are proposed. Starting at the level of capillaries, flow of ISF follows along the basement membranes in the walls of cerebral arteries out of the parenchyma to drain into the lymphatics and CSF [1]–[3]. Conversely, it is shown that CSF enters the parenchyma between glial and pial basement membranes of penetrating arteries [4]–[6]. Nevertheless, the involved structures and the contribution of either flow pathway to fluid balance between the subarachnoid space and interstitial space remains controversial. Low frequency oscillations in vascular tone are referred to as vasomotion and corresponding vasomotion waves are modeled as the driving force for flow of ISF out of the parenchyma [7]. Retinal vessel analysis (RVA) allows non-invasive measurement of retinal vessel vasomotion with respect to diameter changes [8]. Thus, the aim of the study is to investigate vasomotion in RVA signals of SAH and PHH patients.
Recognition of subjects with mild cognitive impairment (MCI) by the use of retinal arterial vessels.
(2019)
Hypertension describes the pathological increase of blood pressure, which is most commonly associated with the increase of vascular wall stiffness [1]. Referring to the “Deutsche Bluthochdruck Liga” this pathology shows a growing trend in our aging society. In order to find novel pharmacological and probably personalized treatments, we want to present a functional approach to study biomechanical properties of a human aortic vascular model.
In this method review we will give an overview of recent studies which were carried out with the CellDrum technology [2] and underline the added value to already existing standard procedures known from the field of physiology.
Herein described CellDrum technology is a system to measure functional mechanical properties of cell monolayers and thin tissue constructs in-vitro. Additionally, the CellDrum enables to elucidate the mechanical response of cells to pharmacological drugs, toxins and vasoactive agents. Due to its highly flexible polymer support, cells can also be mechanically stimulated by steady and cyclic biaxial stretching.