Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1563)
- Fachbereich Elektrotechnik und Informationstechnik (711)
- IfB - Institut für Bioengineering (562)
- Fachbereich Energietechnik (561)
- Fachbereich Chemie und Biotechnologie (537)
- INB - Institut für Nano- und Biotechnologien (533)
- Fachbereich Luft- und Raumfahrttechnik (480)
- Fachbereich Maschinenbau und Mechatronik (262)
- Fachbereich Wirtschaftswissenschaften (205)
- Solar-Institut Jülich (161)
Has Fulltext
- no (4684) (remove)
Language
- English (4684) (remove)
Document Type
- Article (3192)
- Conference Proceeding (1033)
- Part of a Book (191)
- Book (144)
- Doctoral Thesis (30)
- Conference: Meeting Abstract (28)
- Patent (25)
- Other (10)
- Report (9)
- Conference Poster (5)
Keywords
- Gamification (6)
- avalanche (6)
- Earthquake (5)
- Enterprise Architecture (5)
- MINLP (5)
- solar sail (5)
- Additive manufacturing (4)
- Diversity Management (4)
- Energy storage (4)
- Engineering optimization (4)
Assessment of RF Safety of Transmit Coils at 7 Tesla by Experimental and Numerical Procedures (490.)
(2012)
This work presents a methodology for automated
damage-sensitive feature extraction and anomaly
detection under multivariate operational variability
for in-flight assessment of wings. The
method uses a passive excitation approach, i. e.
without the need for artificial actuation. The
modal system properties (natural frequencies and
damping ratios) are used as damage-sensitive
features. Special emphasis is placed on the use
of Fiber Bragg Grating (FBG) sensing technology
and the consideration of Operational and
Environmental Variability (OEV). Measurements
from a wind tunnel investigation with a composite
cantilever equipped with FBG and piezoelectric
sensors are used to successfully detect an impact
damage. In addition, the feasibility of damage
localisation and severity estimation is evaluated
based on the coupling found between damageand
OEV-induced feature changes.
The impact of wake model effects is investigated for two highly
non-planar lifting systems. Dependent on the geometrical
arrangement of the configuration, the wake model shape is found
to considerably affect the estimation. Particularly at higher angles
of attack, an accurate estimation based on the common linear wake
model approaches is involved.
Short term effects of magnetic resonance imaging on excitability of the motor cortex at 1.5T and 7T
(2010)
Rationale and Objectives
The increasing spread of high-field and ultra-high-field magnetic resonance imaging (MRI) scanners has encouraged new discussion of the safety aspects of MRI. Few studies have been published on possible cognitive effects of MRI examinations. The aim of this study was to examine whether changes are measurable after MRI examinations at 1.5 and 7 T by means of transcranial magnetic stimulation (TMS).
Materials and Methods
TMS was performed in 12 healthy, right-handed male volunteers. First the individual motor threshold was specified, and then the cortical silent period (SP) was measured. Subsequently, the volunteers were exposed to the 1.5-T MRI scanner for 63 minutes using standard sequences. The MRI examination was immediately followed by another TMS session. Fifteen minutes later, TMS was repeated. Four weeks later, the complete setting was repeated using a 7-T scanner. Control conditions included lying in the 1.5-T scanner for 63 minutes without scanning and lying in a separate room for 63 minutes. TMS was performed in the same way in each case. For statistical analysis, Wilcoxon's rank test was performed.
Results
Immediately after MRI exposure, the SP was highly significantly prolonged in all 12 subjects at 1.5 and 7 T. The motor threshold was significantly increased. Fifteen minutes after the examination, the measured value tended toward normal again. Control conditions revealed no significant differences.
Conclusion
MRI examinations lead to a transient and highly significant alteration in cortical excitability. This effect does not seem to depend on the strength of the static magnetic field.
Purpose
To assess potential cognitive deficits under the influence of static magnetic fields at various field strengths some studies already exist. These studies were not focused on attention as the most vulnerable cognitive function. Additionally, mostly no magnetic resonance imaging (MRI) sequences were performed.
Materials and Methods
In all, 25 right-handed men were enrolled in this study. All subjects underwent one MRI examination of 63 minutes at 1.5 T and one at 7 T within an interval of 10 to 30 days. The order of the examinations was randomized. Subjects were referred to six standardized neuropsychological tests strictly focused on attention immediately before and after each MRI examination. Differences in neuropsychological variables between the timepoints before and after each MRI examination were assessed and P-values were calculated
Results
Only six subtests revealed significant differences between pre- and post-MRI. In these tests the subjects achieved better results in post-MRI testing than in pre-MRI testing (P = 0.013–0.032). The other tests revealed no significant results.
Conclusion
The improvement in post-MRI testing is only explicable as a result of learning effects. MRI examinations, even in ultrahigh-field scanners, do not seem to have any persisting influence on the attention networks of human cognition immediately after exposure.