Refine
Year of publication
- 2024 (25)
- 2023 (101)
- 2022 (132)
- 2021 (145)
- 2020 (157)
- 2019 (192)
- 2018 (168)
- 2017 (154)
- 2016 (154)
- 2015 (176)
- 2014 (166)
- 2013 (171)
- 2012 (154)
- 2011 (184)
- 2010 (179)
- 2009 (185)
- 2008 (155)
- 2007 (149)
- 2006 (160)
- 2005 (130)
- 2004 (161)
- 2003 (106)
- 2002 (130)
- 2001 (106)
- 2000 (108)
- 1999 (109)
- 1998 (99)
- 1997 (99)
- 1996 (81)
- 1995 (78)
- 1994 (86)
- 1993 (59)
- 1992 (54)
- 1991 (29)
- 1990 (39)
- 1989 (45)
- 1988 (57)
- 1987 (32)
- 1986 (19)
- 1985 (34)
- 1984 (22)
- 1983 (20)
- 1982 (29)
- 1981 (20)
- 1980 (36)
- 1979 (24)
- 1978 (34)
- 1977 (14)
- 1976 (13)
- 1975 (12)
- 1974 (3)
- 1973 (2)
- 1972 (2)
- 1971 (1)
- 1968 (1)
Document Type
- Article (3226)
- Conference Proceeding (1146)
- Part of a Book (184)
- Book (144)
- Doctoral Thesis (30)
- Patent (25)
- Other (9)
- Report (9)
- Working Paper (6)
- Lecture (5)
- Poster (4)
- Preprint (4)
- Talk (4)
- Master's Thesis (2)
- Bachelor Thesis (1)
- Contribution to a Periodical (1)
- Habilitation (1)
Language
- English (4801) (remove)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (12)
- Einspielen <Werkstoff> (10)
- CAD (8)
- civil engineering (8)
- Bauingenieurwesen (7)
- Blitzschutz (6)
- FEM (6)
- Gamification (6)
- Limit analysis (6)
- Shakedown analysis (6)
- avalanche (6)
- shakedown analysis (6)
- Clusterion (5)
- Earthquake (5)
- Enterprise Architecture (5)
- MINLP (5)
- solar sail (5)
- Air purification (4)
- Diversity Management (4)
Institute
- Fachbereich Medizintechnik und Technomathematik (1668)
- Fachbereich Elektrotechnik und Informationstechnik (693)
- IfB - Institut für Bioengineering (620)
- Fachbereich Energietechnik (579)
- INB - Institut für Nano- und Biotechnologien (555)
- Fachbereich Chemie und Biotechnologie (534)
- Fachbereich Luft- und Raumfahrttechnik (477)
- Fachbereich Maschinenbau und Mechatronik (278)
- Fachbereich Wirtschaftswissenschaften (207)
- Solar-Institut Jülich (164)
- Fachbereich Bauingenieurwesen (153)
- ECSM European Center for Sustainable Mobility (79)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (67)
- Nowum-Energy (28)
- Fachbereich Gestaltung (25)
- Institut fuer Angewandte Polymerchemie (23)
- Sonstiges (21)
- Fachbereich Architektur (20)
- Freshman Institute (18)
- Kommission für Forschung und Entwicklung (18)
Cryopumps without liquid nitrogen shielding are used to provide a vacuum of 10−6 torr in the spectrometer. The vacuum system is subdivided in three sections that can be separated by valves.
The first section (scattering chamber) has a volume of 60 l, two rotation transmissions with 35 cm dia and a sliding seal that allows a rotation of 160° without deteriorating the vacuum. The second section includes the vacuum chambers inside the magnets with 6 × 80 cm cross-section and a length of 1200 cm. The third section (detector box) has a volume of 4300 l and contains a moveable detector system. The gas inside the detector with a pressure of 760 torr is separated from the vacuum by a 15 μm mylar foil with an area of 300 cm2. The detector box can be valved off by a valve with the dimension of 10 × 100 cm.
The layout of system is given. The instrumentation and the interlock system are described. First experiences with this system are presented.
BIG KARL and COSY
(1995)
Plans for investigations of subthreshold K+ production in p+A collisions / O. W. B. Schult [u.a.]
(1995)
Living cells are complex biological systems transforming metabolites taken up from the surrounding medium. Monitoring the responses of such cells to certain substrate concentrations is a challenging task and offers possibilities to gain insight into the vitality of a community influenced by the growth environment. Cell-based sensors represent a promising platform for monitoring the metabolic activity and thus, the “welfare” of relevant organisms. In the present study, metabolic responses of the model bacterium Escherichia coli in suspension, layered onto a capacitive field-effect structure, were examined to pulses of glucose in the concentration range between 0.05 and 2 mM. It was found that acidification of the surrounding medium takes place immediately after glucose addition and follows Michaelis–Menten kinetic behavior as a function of the glucose concentration. In future, the presented setup can, therefore, be used to study substrate specificities on the enzymatic level and may as well be used to perform investigations of more complex metabolic responses. Conclusions and perspectives highlighting this system are discussed.
Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers
(2013)
Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution.
The semiconductor field-effect platform represents a powerful tool for detecting the adsorption and binding of charged macromolecules with direct electrical readout. In this work, a capacitive electrolyte–insulator–semiconductor (EIS) field-effect sensor consisting of an Al-p-Si-SiO2 structure has been applied for real-time in situ electrical monitoring of the layer-by-layer formation of polyelectrolyte (PE) multilayers (PEM). The PEMs were deposited directly onto the SiO2 surface without any precursor layer or drying procedures. Anionic poly(sodium 4-styrene sulfonate) and cationic weak polyelectrolyte poly(allylamine hydrochloride) have been chosen as a model system. The effect of the ionic strength of the solution, polyelectrolyte concentration, number and polarity of the PE layers on the characteristics of the PEM-modified EIS sensors have been studied by means of capacitance–voltage and constant-capacitance methods. In addition, the thickness, surface morphology, roughness and wettabilityof the PE mono- and multilayers have been characterised by ellipsometry, atomic force microscopy and water contact-angle methods, respectively. To explain potential oscillations on the gate surface and signal behaviour of the capacitive field-effect EIS sensor modified with a PEM, a simplified electrostatic model that takes into account the reduced electrostatic screening of PE charges by mobile ions within the PEM has been proposed and discussed.