Article
Refine
Year of publication
Institute
- Fachbereich Chemie und Biotechnologie (605) (remove)
Document Type
- Article (605) (remove)
Keywords
- Heparin (3)
- Bacillaceae (2)
- Biotechnological application (2)
- Butanol (2)
- Chemometrics (2)
- IR spectroscopy (2)
- NMR spectroscopy (2)
- Principal component analysis (2)
- Spectroscopy (2)
- Standardization (2)
With the prevalence of glucosamine- and chondroitin-containing dietary supplements for people with osteoarthritis in the marketplace, it is important to have an accurate and reproducible analytical method for the quantitation of these compounds in finished products. NMR spectroscopic method based both on low- (80 MHz) and high- (500–600 MHz) field NMR instrumentation was established, compared and validated for the determination of chondroitin sulfate and glucosamine in dietary supplements. The proposed method was applied for analysis of 20 different dietary supplements. In the majority of cases, quantification results obtained on the low-field NMR spectrometer are similar to those obtained with high-field 500–600 MHz NMR devices. Validation results in terms of accuracy, precision, reproducibility, limit of detection and recovery demonstrated that the developed method is fit for purpose for the marketed products. The NMR method was extended to the analysis of methylsulfonylmethane, adulterant maltodextrin, acetate and inorganic ions. Low-field NMR can be a quicker and cheaper alternative to more expensive high-field NMR measurements for quality control of the investigated dietary supplements. High-field NMR instrumentation can be more favorable for samples with complex composition due to better resolution, simultaneously giving the possibility of analysis of inorganic species such as potassium and chloride.
Electronic cigarettes (e-cigarettes) have become popular worldwide with the market growing exponentially in some countries. The absence of product standards and safety regulations requires urgent development of analytical methodologies for the holistic control of the growing diversity of such products. An approach based on low-field nuclear magnetic resonance (LF-NMR) at 80 MHz is presented for the simultaneous determination of key parameters: carrier solvents (vegetable glycerine (VG), propylene glycol (PG) and water), total nicotine as well as free-base nicotine fraction. Moreover, qualitative and quantitative determination of fourteen weak organic acids deliberately added to enhance sensory characteristics of e-cigarettes was possible. In most cases these parameters can be rapidly and conveniently determined without using any sample manipulation such as dilution, extraction or derivatization steps. The method was applied for 37 authentic e-cigarettes samples. In particular, eight different organic acids with the content up to 56 mg/mL were detected. Due to its simplicity, the method can be used in routine regulatory control as well as to study release behaviour of nicotine and other e-cigarettes constituents in different products.
Several unconnected laboratory experiments are usually offered for students in instrumental analysis lab. To give the students a more rational overview of the most common instrumental techniques, a new laboratory experiment was developed. Marketed pain relief drugs, familiar consumer products with one to three active components, namely, acetaminophen (paracetamol), acetylsalicylic acid (ASA), and caffeine, were selected. Common analytical methods were compared regarding the performance of qualitative and quantitative analysis of unknown tablets: UV–visible (UV–vis), infrared (IR), and nuclear magnetic resonance (NMR) spectroscopies, as well as high-performance liquid chromatography (HPLC). The students successfully uncovered the composition of formulations, which were divided into three difficulty categories. Students were shown that in addition to simple mixtures handled in theoretical classes, the composition of complex drug products can also be uncovered. By comparing the performance of different techniques, students deepen their understanding and compare the efficiency of analytical methods in the context of complex mixtures. The laboratory experiment can be adjusted for graduate level by including extra tasks such as method optimization, validation, and 2D spectroscopic techniques.
Thin films of poly(ethyleneterephthalate) [PET]were exposed to radiation dose ranging from 10 to 30 kGy by using gamma rays in the range 12.8-177.8 MGy using swift light ions of hydrogen. There was no effect of the radiation dose on the optical behaviour of PET as a result of exposure to radiation dose up to 30 kGy brought about by gamma rays but a significant decrease in the optical band gap values was observed when PET was exposed to swift light ions of hydrogen. The data obtained are discussed in terms of optical studies carried out on PET using swift heavy ions.
Biotechnologie und die mit ihr verbundenen technischen Prozesse prägen seit Jahrtausenden die Entwicklung der Menschheit. Ausgehend von empirischen Verfahren, insbesondere zur Herstellung von Lebensmitteln und täglichen Gebrauchsgütern, haben sich diese Disziplinen zu einem der innovativsten Zukunftsfelder entwickelt. Durch das immer detailliertere Verständnis zellulärer Vorgänge können mittlerweile Produktionsstämme gezielt optimiert werden. Im Zusammenspiel mit moderner Prozesstechnik können so eine Vielzahl von Bulk- und Feinchemikalien sowie Pharmazeutika effizient hergestellt werden. In diesem Artikel werden exemplarisch einige der aktuellen Trends vorgestellt.
For several thousand years, biotechnology and its associated technical processes have had a great impact on the development of mankind. Based on empirical methods, in particular for the production of foodstuffs and daily commodities, these disciplines have become one of the most innovative future issues. Due to the increasing detailed understanding of cellular processes, production strains can now be optimized. In combination with modern bioprocesses, a variety of bulk and fine chemicals as well as pharmaceuticals can be produced efficiently. In this article, some of the current trends in biotechnology are discussed.
For the successful implementation of microfluidic reaction systems, such as PCR and electrophoresis, the movement of small liquid volumes is essential. In conventional lab-on-a-chip-platforms, solvents and samples are passed through defined microfluidic channels with complex flow control installations. The droplet actuation platform presented here is a promising alternative. With it, it is possible to move a liquid drop (microreactor) on a planar surface of a reaction platform (lab-in-a-drop). The actuation of microreactors on the hydrophobic surface of the platform is based on the use of magnetic forces acting on the outer shell of the liquid drops which is made of a thin layer of superhydrophobic magnetite particles. The hydrophobic surface of the platform is needed to avoid any contact between the liquid core and the surface to allow a smooth movement of the microreactor. On the platform, one or more microreactors with volumes of 10 µL can be positioned and moved simultaneously. The platform itself consists of a 3 x 3 matrix of electrical double coils which accommodate either neodymium or iron cores. The magnetic field gradients are automatically controlled. By variation of the magnetic field gradients, the microreactors' magnetic hydrophobic shell can be manipulated automatically to move the microreactor or open the shell reversibly. Reactions of substrates and corresponding enzymes can be initiated by merging the microreactors or bringing them into contact with surface immobilized catalysts.
In the field of biotechnology and molecular biology, the use of small liquid volumes has significant advantages. In particular, screening and optimization runs with acceptable amounts of expensive and hardly available catalysts, reagents, or biomolecules are feasible with microfluidic technologies. The presented new microfluidic system is based on the inclusion of small liquid volumes by a protective shell of magnetizable microparticles. Hereby, discrete aqueous microreactor drops with volumes of 1–30 μL can be formed on a simple planar surface. A digital movement and manipulation of the microreactor is performed by overlapping magnetic forces. The magnetic forces are generated by an electrical coil matrix positioned below a glass plate. With the new platform technology, several discrete reaction compartments can be moved simultaneously on one surface. Due to the magnetic fields, the reactors can even be merged to initiate reactions by mixing or positioned above surface-immobilized catalysts and then opened by magnetic force. Comparative synthesis routes of the magnetizable shell particles and superhydrophobic glass slides including their performance and stability with the reaction platform are described. The influence of diffusive mass transport during the catalyzed reaction is discussed by evaluation finite element model of the microreactor. Furthermore, a first model dye reaction of the enzyme laccase has been established.
Comparison of intravenous immunoglobulins for naturally occurring autoantibodies against amyloid-β
(2010)
Intravenous immunoglobulins (IVIG) are currently used for therapeutic purposes in autoimmune disorders. Recently, we demonstrated the presence of naturally occurring antibodies against amyloid- β (nAbs-Aβ) within the pool of IVIG. In this study, we compared different brands of IVIG for nAbs-Aβ and have found differences in the specificity of the nAbs-Aβ towards Aβ1–40 and Aβ1–42 . We analyzed the influence of a pH-shift over the course of antibody storage using ELISA and investigated antibody dimerization at acidic and neutral pH as well as differences in the IgG subclass distributions among the IVIG using both HPLC and a nephelometric assay. Furthermore, we investigated the epitope region of purified nAbs-Aβ. The differences found in Aβ specificity are not directly proportionate to the binding nature of these antibodies when administered in vivo. This information, however, may serve as a guide when choosing the commercial source of IVIG for therapeutic applications in Alzheimer's disease
Tricarbonylrhenium(I) and -technetium(I) halide (halide = Cl and Br) complexes of ligands derived from 4,5-diazafluoren-9-one (df) and 1,10-phenanthroline-5,6-dione (phen) derivatives of benzoic and 2-hydroxybenzoic acid hydrazides have been prepared. The complexes have been characterized by elemental analysis, MS, IR, 1H NMR and absorption and emission UV/Vis spectroscopic methods. The metal centres (ReI and TcI) are coordinated through the nitrogen imine atoms and establish five-membered chelate rings, whereas the hydrazone groups stand uncoordinated. The 1H NMR spectra suggest the same behaviour in solution on the basis of only marginal variations in the chemical shifts of the hydrazine protons.