Part of a Book
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (62) (remove)
Has Fulltext
- no (62) (remove)
Document Type
- Part of a Book (62) (remove)
Keywords
- Biomolecular logic gate (1)
- Bladder (1)
- Bone sawing (1)
- Chemical imaging (1)
- Coat protein (1)
- Coefficient of ocular rigidity (1)
- Corneo-scleral shell (1)
- DNA (1)
- Differential tonometry (1)
- Dry surfaces (1)
- Enzyme biosensor (1)
- Enzyme nanocarrier (1)
- Eyeball (1)
- FGF23 (1)
- Field-effect device (1)
- Field-effect sensor (1)
- Glucose biosensor (1)
- Glucose oxidase (1)
- Gold nanoparticle (1)
- Growth modelling (1)
- Klotho (1)
- Light-addressable potentiometric sensor (1)
- Limit analysis (1)
- Mechanical simulation (1)
- Microbial adhesion (1)
- Multimode failure (1)
- Muscle fibers (1)
- Niacin (1)
- Non-linear optimization (1)
- PTH (1)
- Passive stretching (1)
- Pelvic floor dysfunction (1)
- Pelvic muscle (1)
- Phosphate (1)
- Potentiometry (1)
- Pressure-volume relationship (1)
- Reconstruction (1)
- Reliability analysis (1)
- Riboflavin (1)
- Sampling methods (1)
- Shakedown analysis (1)
- Surface microorganisms (1)
- Swabbing (1)
- Thiamine (1)
- Tobacco mosaic virus (TMV) (1)
- Ureter (1)
- Vitamin A (1)
- Vitamin B (1)
- Vitamin D (1)
- training simulator (1)
- virtual reality (1)
The term ocular rigidity is widely used in clinical ophthalmology. Generally it is assumed as a resistance of the whole eyeball to mechanical deformation and relates to biomechanical properties of the eye and its tissues. Basic principles and formulas for clinical tonometry, tonography and pulsatile ocular blood flow measurements are based on the concept of ocular rigidity. There is evidence for altered ocular rigidity in aging, in several eye diseases and after eye surgery. Unfortunately, there is no consensual view on ocular rigidity: it used to make a quite different sense for different people but still the same name. Foremost there is no clear consent between biomechanical engineers and ophthalmologists on the concept. Moreover ocular rigidity is occasionally characterized using various parameters with their different physical dimensions. In contrast to engineering approach, clinical approach to ocular rigidity claims to characterize the total mechanical response of the eyeball to its deformation without any detailed considerations on eye morphology or material properties of its tissues. Further to the previous chapter this section aims to describe clinical approach to ocular rigidity from the perspective of an engineer in an attempt to straighten out this concept, to show its advantages, disadvantages and various applications.
Twee Kanten van één Medaille
(2020)
Epilepsy
(2010)
Biocomposite Materials Based on Carbonized Rice Husk in Biomedicine and Environmental Applications
(2020)
This chapter describes the prospects for biomedical and environmental engineering applications of heterogeneous materials based on nanostructured carbonized rice husk. Efforts in engineering enzymology are focused on the following directions: development and optimization of immobilization methods leading to novel biotechnological and biomedical applications; construction of biocomposite materials based on individual enzymes, multi-enzyme complexes and whole cells, targeted on realization of specific industrial processes. Molecular biological and biochemical studies on cell adhesion focus predominantly on identification, isolation and structural analysis of attachment-responsible biological molecules and their genetic determinants. The chapter provides a short overview of applications of the biocomposite materials based of nanostructured carbonized adsorbents. It emphasizes that further studies and better understanding of the interactions between CNS and microbial cells are necessary. The future use of living cells as biocatalysts, especially in the environmental field, needs more systematic investigations of the microbial adsorption phenomenon.
This work describes a procedure to yield attenuation maps from MR images which are used for the absorption correction (AC) of brain PET data. Such an approach could be mandatory for future combined PET and MRI scanners, which probably do not include a transmission facility. T1-weighted MR images were segmented into brain tissue, bone, soft tissue, and sinus; attenuation coefficients corresponding to elemental composition and density as well as to 511 keV photon energy were respectively assigned. Attenuation maps containing up to four compartments were created and forward projected into sinograms with attenuation factors which then were used for AC during reconstruction of FDG-PET data. The commonly used AC based on a radioactive (68Ge) transmission scan served as reference. The reconstructed radioactivity values obtained with the MRI-based AC were about 20% lower than those obtained with PET-based AC if the skull was not taken into account. Considering the skull the difference was still about 10%. Our investigations demonstrate the feasibility of a MRI-based AC, but revealed also the necessity of a satisfying delineation of bone thickness which tends to be underestimated in our first approach of T1-weighted MR image segmentation.
The method of fundamental solutions is applied to the approximate computation of interior transmission eigenvalues for a special class of inhomogeneous media in two dimensions. We give a short approximation analysis accompanied with numerical results that clearly prove practical convenience of our alternative approach.
The coupling of charged molecules, nanoparticles, and more generally, inorganic/organic nanohybrids with semiconductor field-effect devices based on an electrolyte–insulator–semiconductor (EIS) system represents a very promising strategy for the active tuning of electrochemical properties of these devices and, thus, opening new opportunities for label-free biosensing by the intrinsic charge of molecules. The simplest field-effect sensor is a capacitive EIS sensor, which represents a (bio-)chemically sensitive capacitor. In this chapter, selected examples of recent developments in the field of label-free biosensing using nanomaterial-modified capacitive EIS sensors are summarized. In the first part, we present applications of EIS sensors modified with negatively charged gold nanoparticles for the label-free electrostatic detection of positively charged small proteins and macromolecules, for monitoring the layer-by-layer formation of oppositely charged polyelectrolyte (PE) multilayers as well as for the development of an enzyme-based biomolecular logic gate. In the second part, examples of a label-free detection by means of EIS sensors modified with a positively charged weak PE layer are demonstrated. These include electrical detection of on-chip and in-solution hybridized DNA (deoxyribonucleic acid) as well as an EIS sensor with pH-responsive weak PE/enzyme multilayers for enhanced field-effect biosensing.
An array of electrically isolated nanoplate field-effect silicon-on-insulator (SOI) capacitors as a new transducer structure for multiparameter (bio-)chemical sensing is presented. The proposed approach allows addressable biasing and electrical readout of multiple nanoplate field-effect capacitive (bio-)chemical sensors on the same SOI chip, as well as differential-mode measurements. The realized sensor chip has been applied for pH and penicillin concentration measurements, electrical monitoring of polyelectrolyte multilayer formation, and the label-free electrical detection of consecutive deoxyribonucleic acid (DNA) hybridization and denaturation events.
Activated carbons are known as excellent adsorbents. Their applications include the adsorptive removal of color, odor, taste, undesirable organic and inorganic pollutants from drinking and waste water; air purification in inhabited spaces; purification of many chemicals, pharmaceutical products and many others. This chapter elucidates the role of normal microflora in the maintenance of human health and presents materials on possible clinical displays of microecological infringements and ways of their correction. It presents new developments concerning new probiotics with immobilized Lactobacillus and Bacillus. The chapter considers the mechanisms of the intestine disbacteriosis correction by sorbed probiotics. It demonstrates the advantages and creation prospects of immobilized probiotics developed on the basis of carbonized rice husk. There are great prospects for the development of medical biotechnology due to use of carbon sorbents with a nanostructured surface. Microbial communities form a biocenosis of the biotope and together with the host organism create permanent or temporary ecosystems.
Enzyme und Biosensorik
(2018)
Enzymbasierte Biosensoren finden seit mehr als fünf Jahrzehnten einen prosperierenden Wachstumsmarkt und werden zunehmend auch in biotechnologischen Prozessen eingesetzt. In diesem Kapitel werden, ausgehend vom Sensorbegriff und typischen Kenngrößen für Biosensoren (Abschn. 18.1), elektrochemische Enzym-Biosensoren vorgestellt und deren typischen Einsatzgebiete diskutiert (Abschn. 18.2). Ein Blick über den „Tellerrand“ hinaus zeigt alternative Transduktorprinzipien (Abschn. 18.3) und führt abschließend in aktuelle Forschungstrends ein (Abschn. 18.4).