Refine
Year of publication
- 2011 (82) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (82) (remove)
Document Type
- Article (69)
- Conference Proceeding (6)
- Report (3)
- Book (2)
- Doctoral Thesis (2)
Keywords
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- plant scanner (2)
- Anastomose (1)
- Anastomosis (1)
- Arthosetherapie (1)
- Biomechanics (1)
- Biomechanik (1)
- Bioreaktor (1)
- Blutzellenlagerung (1)
- Dattel (1)
- Eisschicht (1)
- Finite element method (1)
- Finite-Elemente-Methode (1)
- Gonarthrose (1)
- Harnleiter (1)
- Hemoglobin structure (1)
- Hämoglobin (1)
- Hämoglobinstruktur (1)
- Kniegelenkarthrose (1)
- MBST (1)
- Organkultur (1)
- Pflanzenstress (1)
- Red blood cell storage (1)
- Sonde (1)
- Tissue Engineering (1)
- arthrosis therapy (1)
- date palm tree (1)
- gonarthrosis (1)
- plant stress (1)
- subsurface ice research (1)
- subsurface probe (1)
This paper presents a novel numerical procedure for computing limit and shakedown loads of structures using a node-based smoothed FEM in combination with a primal–dual algorithm. An associated primal–dual form based on the von Mises yield criterion is adopted. The primal-dual algorithm together with a Newton-like iteration are then used to solve this associated primal–dual form to determine simultaneously both approximate upper and quasi-lower bounds of the plastic collapse limit and the shakedown limit. The present formulation uses only linear approximations and its implementation into finite element programs is quite simple. Several numerical examples are given to show the reliability, accuracy, and generality of the present formulation compared with other available methods.
In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit.
Plant physiology and plant stress: Plant physiology will be much more important for human mankind because of yield and cultivation limits of crops determined by their resistance to stress. To assess and counteract various stress factors it is necessary to conduct plant research to gain information and results on plant physiology.
The demand of replacements for inoperable organs exceeds the amount of available organ transplants. Therefore, tissue engineering developed as a multidisciplinary field of research for autologous in-vitro organs. Such three dimensional tissue constructs request the application of a bioreactor. The UREPLACE bioreactor is used to grow cells on tubular collagen scaffolds OPTIMAIX Sponge 1 with a maximal length of 7 cm, in order to culture in vitro an adequate ureter replacement. With a rotating unit, (urothelial) cells can be placed homogeneously on the inner scaffold surface. Furthermore, a stimulation is combined with this bioreactor resulting in an orientation of muscle cells. These culturing methods request a precise control of several parameters and actuators. A combination of a LabBox and the suitable software LabVision is used to set and conduct parameters like rotation angles, velocities, pressures and other important cell culture values. The bioreactor was tested waterproof successfully. Furthermore, the temperature controlling was adjusted to 37 °C and the CO2 - concentration regulated to 5 %. Additionally, the pH step responses of several substances showed a perfect functioning of the designed flow chamber. All used software was tested and remained stable for several days.
Summary: This paper presents a methodology to study and understand the mechanics of stapled anastomotic behaviors by combining empirical experimentation and finite element analysis. Performance of stapled anastomosis is studied in terms of leakage and numerical results which are compared to in vitro experiments performed on fresh porcine tissue. Results suggest that leaks occur between the tissue and staple legs penetrating through the tissue.