Refine
Year of publication
- 2006 (160) (remove)
Document Type
- Article (86)
- Conference Proceeding (60)
- Book (9)
- Lecture (2)
- Part of a Book (1)
- Master's Thesis (1)
- Report (1)
Language
- English (160) (remove)
Keywords
- Biosensor (23)
- Technische Mechanik (2)
- biosensor (2)
- 3-nitrofluoranthene (1)
- Asteroid Deflection (1)
- BTEX compounds (1)
- Bauingenieurwesen (1)
- Biosensorik (1)
- Bruchmechanik (1)
- CAD (1)
- CO (1)
- Conducing polymer (1)
- ECT (1)
- EPN (1)
- Elastostatics (1)
- Finite-Elemente-Methode (1)
- Fluorescence (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Gunn diode (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (64)
- Fachbereich Luft- und Raumfahrttechnik (21)
- IfB - Institut für Bioengineering (20)
- INB - Institut für Nano- und Biotechnologien (18)
- Fachbereich Elektrotechnik und Informationstechnik (17)
- Fachbereich Maschinenbau und Mechatronik (15)
- Fachbereich Chemie und Biotechnologie (12)
- Fachbereich Energietechnik (12)
- Fachbereich Wirtschaftswissenschaften (7)
- Fachbereich Bauingenieurwesen (3)
- Freshman Institute (3)
- Solar-Institut Jülich (3)
- ECSM European Center for Sustainable Mobility (1)
- Fachbereich Architektur (1)
- Fachbereich Gestaltung (1)
- Sonstiges (1)
Functional testing and characterisation of ISFETs on wafer level by means of a micro-droplet cell
(2006)
A wafer-level functionality testing and characterisation system for ISFETs (ionsensitive field-effect transistor) is realised by means of integration of a specifically designed capillary electrochemical micro-droplet cell into a commercial wafer prober-station. The developed system allows the identification and selection of “good” ISFETs at the earliest stage and to avoid expensive bonding, encapsulation and packaging processes for nonfunctioning ISFETs and thus, to decrease costs, which are wasted for bad dies. The developed system is also feasible for wafer-level characterisation of ISFETs in terms of sensitivity, hysteresis and response time. Additionally, the system might be also utilised for wafer-level testing of further electrochemical sensors.
A concept for a sensitive micro total analysis system for high throughput fluorescence imaging
(2006)
This paper discusses possible methods for on-chip fluorescent imaging for integrated bio-sensors. The integration of optical and electro-optical accessories, according to suggested methods, can improve the performance of fluorescence imaging. It can boost the signal to background ratio by a few orders of magnitudes in comparison to conventional discrete setups. The methods that are present in this paper are oriented towards building reproducible arrays for high-throughput micro total analysis systems (µTAS). The first method relates to side illumination of the fluorescent material placed into microcompartments of the lab-on-chip. Its significance is in high utilization of excitation energy for low concentration of fluorescent material. The utilization of a transparent µLED chip, for the second method, allows the placement of the excitation light sources on the same optical axis with emission detector, such that the excitation and emission rays are directed controversly. The third method presents a spatial filtering of the excitation background.
A solid-state amperometric hydrogen sensor based on a protonated Nafion membrane and catalytic active electrode operating at room temperature was fabricated and tested. Ionic conducting polymer-metal electrode interfaces were prepared chemically by using the impregnation-reduction method. The polymer membrane was impregnated with tetra-ammine platinum chloride hydrate and the metal ions were subsequently reduced by using either sodium tetrahydroborate or potassium tetrahydroborate. The hydrogen sensing characteristics with air as reference gas is reported. The sensors were capable of detecting hydrogen concentrations from 10 ppm to 10% in nitrogen. The response time was in the range of 10-30 s and a stable linear current output was observed. The thin Pt films were characterized by XRD, Infrared Spectroscopy, Optical Microscopy, Atomic Force Microscopy, Scanning Electron Microscopy and EDAX.
Micromachined thermal heater platforms offer low electrical power consumption and high modulation speed, i.e. properties which are advantageous for realizing nondispersive infrared (NDIR) gas- and liquid monitoring systems. In this paper, we report on investigations on silicon-on-insulator (SOI) based infrared (IR) emitter devices heated by employing different kinds of metallic and semiconductor heater materials. Our results clearly reveal the superior high-temperature performance of semiconductor over metallic heater materials. Long-term stable emitter operation in the vicinity of 1300 K could be attained using heavily antimony-doped tin dioxide (SnO2:Sb) heater elements.