Article
Refine
Year of publication
- 2024 (38)
- 2023 (76)
- 2022 (91)
- 2021 (109)
- 2020 (132)
- 2019 (120)
- 2018 (125)
- 2017 (108)
- 2016 (116)
- 2015 (126)
- 2014 (142)
- 2013 (139)
- 2012 (130)
- 2011 (182)
- 2010 (178)
- 2009 (199)
- 2008 (180)
- 2007 (176)
- 2006 (180)
- 2005 (188)
- 2004 (214)
- 2003 (154)
- 2002 (167)
- 2001 (157)
- 2000 (173)
- 1999 (153)
- 1998 (165)
- 1997 (154)
- 1996 (140)
- 1995 (147)
- 1994 (135)
- 1993 (107)
- 1992 (102)
- 1991 (74)
- 1990 (82)
- 1989 (79)
- 1988 (80)
- 1987 (77)
- 1986 (65)
- 1985 (59)
- 1984 (56)
- 1983 (47)
- 1982 (38)
- 1981 (39)
- 1980 (50)
- 1979 (43)
- 1978 (41)
- 1977 (22)
- 1976 (25)
- 1975 (18)
- 1974 (13)
- 1973 (6)
- 1972 (15)
- 1971 (7)
- 1970 (2)
- 1968 (2)
- 1967 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1591)
- Fachbereich Wirtschaftswissenschaften (705)
- Fachbereich Elektrotechnik und Informationstechnik (638)
- Fachbereich Energietechnik (609)
- Fachbereich Chemie und Biotechnologie (602)
- INB - Institut für Nano- und Biotechnologien (542)
- Fachbereich Maschinenbau und Mechatronik (484)
- IfB - Institut für Bioengineering (449)
- Fachbereich Luft- und Raumfahrttechnik (379)
- Fachbereich Bauingenieurwesen (333)
Language
Document Type
- Article (5644) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- Multimediamarkt (6)
- Rapid prototyping (5)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- Rapid Prototyping (4)
- biosensors (4)
Purpose
In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model.
Material and Methods
Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio).
Results
In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF.
Conclusion
The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018.
Ein Drittel der Mitarbeiter der Saint-Gobain Glass Deutschland
GmbH hat drei Jahre lang regelmäßig seinen Rücken trainiert.
Mit Erfolg, wie eine abschließende Evaluation in Zusammenarbeit
mit der FH Aachen zeigt. Die Fehltage der Trainingsteilnehmer
sind enorm zurückgegangen, während die untrainierten Kollegen
weiterhin unter Rückenbeschwerden leiden.
Investigation of TRPV1 loss-of-function phenotypes in transgenic shRNA expressing and knockout mice
(2008)
Numerical avalanche dynamics models have become an essential part of snow engineering. Coupled with field observations and historical records, they are especially helpful in understanding avalanche flow in complex terrain. However, their application poses several new challenges to avalanche engineers. A detailed understanding of the avalanche phenomena is required to construct hazard scenarios which involve the careful specification of initial conditions (release zone location and dimensions) and definition of appropriate friction parameters. The interpretation of simulation results requires an understanding of the numerical solution schemes and easy to use visualization tools. We discuss these problems by presenting the computer model RAMMS, which was specially designed by the SLF as a practical tool for avalanche engineers. RAMMS solves the depth-averaged equations governing avalanche flow with accurate second-order numerical solution schemes. The model allows the specification of multiple release zones in three-dimensional terrain. Snow cover entrainment is considered. Furthermore, two different flow rheologies can be applied: the standard Voellmy–Salm (VS) approach or a random kinetic energy (RKE) model, which accounts for the random motion and inelastic interaction between snow granules. We present the governing differential equations, highlight some of the input and output features of RAMMS and then apply the models with entrainment to simulate two well-documented avalanche events recorded at the Vallée de la Sionne test site.
Two- and three-dimensional avalanche dynamics models are being increasingly used in hazard-mitigation studies. These models can provide improved and more accurate results for hazard mapping than the simple one-dimensional models presently used in practice. However, two- and three-dimensional models generate an extensive amount of output data, making the interpretation of simulation results more difficult. To perform a simulation in three-dimensional terrain, numerical models require a digital elevation model, specification of avalanche release areas (spatial extent and volume), selection of solution methods, finding an adequate calculation resolution and, finally, the choice of friction parameters. In this paper, the importance and difficulty of correctly setting up and analysing the results of a numerical avalanche dynamics simulation is discussed. We apply the two-dimensional simulation program RAMMS to the 1968 extreme avalanche event In den Arelen. We show the effect of model input variations on simulation results and the dangers and complexities in their interpretation.
MultiChannel Photomultipliers (PM), like the R7600-00-M64 or R5900-00-M64 from Hamamatsu, are often chosen as photodetectors in high-resolution positron emission tomography (PET). A major problem of this PM is the nonuniform channel gain. In order to solve this problem, light attenuating masks were created. The aim of the masks is a homogenization of the output of all 64 channels using different hole sizes at the channel positions. The hole area, which is individually defined for the different channels, is inversely proportional to the channel gain. The measurements by inserting light attenuating masks improved a homogenization to a ratio of 1:1.2.
Design, evaluation and comparison of endorectal coils for hybrid MR-PET imaging of the prostate
(2020)
Prostate cancer is one of the most common cancers among men and its early detection is critical for its successful treatment. The use of multimodal imaging, such as MR-PET, is most advantageous as it is able to provide detailed information about the prostate. However, as the human prostate is flexible and can move into different positions under external conditions, it is important to localise the focused region-of-interest using both MRI and PET under identical circumstances. In this work, we designed five commonly used linear and quadrature radiofrequency surface coils suitable for hybrid MR-PET use in endorectal applications. Due to the endorectal design and the shielded PET insert, the outer face of the coils investigated was curved and the region to be imaged was outside the volume of the coil. The tilting angles of the coils were varied with respect to the main magnetic field direction. This was done to approximate the various positions from which the prostate could be imaged. The transmit efficiencies and safety excitation efficiencies from simulations, together with the signal-to-noise ratios from the MR images were calculated and analysed. Overall, it was found that the overlapped loops driven in quadrature were superior to the other types of coils we tested. In order to determine the effect of the different coil designs on PET, transmission scans were carried out, and it was observed that the differences between attenuation maps with and without the coils were negligible. The findings of this work can provide useful guidance for the integration of such coil designs into MR-PET hybrid systems in the future.