Conference Proceeding
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (243) (remove)
Document Type
- Conference Proceeding (243) (remove)
Keywords
- Biosensor (25)
- CAD (11)
- Finite-Elemente-Methode (11)
- civil engineering (11)
- Bauingenieurwesen (10)
- Einspielen <Werkstoff> (6)
- shakedown analysis (6)
- Clusterion (4)
- Limit analysis (4)
- Natural language processing (4)
- limit analysis (4)
- Air purification (3)
- Hämoglobin (3)
- Luftreiniger (3)
- Plasmacluster ion technology (3)
- Raumluft (3)
- Shakedown (3)
- Shakedown analysis (3)
- Sonde (3)
- Traglast (3)
- Bruchmechanik (2)
- Clustering (2)
- Einspielanalyse (2)
- Eisschicht (2)
- Erythrozyt (2)
- FEM (2)
- Information extraction (2)
- Kohlenstofffaser (2)
- Lipopolysaccharide (2)
- Ratcheting (2)
- Stickstoffmonoxid (2)
- Traglastanalyse (2)
- biosensor (2)
- celldrum technology (2)
- lipopolysaccharides (2)
- nitric oxide gas (2)
- ratchetting (2)
- shakedown (2)
- 3-nitrofluoranthene (1)
- Active learning (1)
- Adsorption (1)
- Agent-based modeling (1)
- Agent-based simulation (1)
- Analytical models (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomose (1)
- Anastomosis (1)
- Autofluoreszenzverfahren (1)
- BTEX compounds (1)
- Bakterien (1)
- Bio-Sensors (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Biophoton (1)
- Biosensorik (1)
- Blitzschutz (1)
- CAD ; (1)
- CO (1)
- Chance constrained programming (1)
- Cloud Computing (1)
- Cloud Service Broker (1)
- Comparative simulation (1)
- Conducing polymer (1)
- Database (1)
- Dattel (1)
- Deep learning (1)
- Dekontamination (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- ECT (1)
- EEG (1)
- EPN (1)
- Einspiel-Analyse (1)
- Elastodynamik (1)
- Elektrodynamik (1)
- Endothelzelle (1)
- Energy dispatch (1)
- Energy market (1)
- Energy market design (1)
- Evolution of damage (1)
- Exact Ilyushin yield surface (1)
- Extension fracture (1)
- Extension strain criterion (1)
- FEM-Programm (1)
- FEM-computation (1)
- Fehlerstellen (1)
- Festkörper (1)
- Fibroblast (1)
- Finite element method (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fluorescence (1)
- Focusing (1)
- Force (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Grid Computing (1)
- Gunn diode (1)
- Heavy metal detection (1)
- High throughput experimentation (1)
- Hotplate (1)
- Human Factors (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Hydrogen sensor (1)
- I3S 2005 (1)
- ISFET (1)
- Impedance Spectroscopy (1)
- Information Extraction (1)
- Information Integration Tools (1)
- Instruments (1)
- International Symposium on Sensor Science (1)
- Iterative learning control (1)
- Knee (1)
- Knowledge Management (1)
- Körpertemperatur (1)
- LED chip (1)
- LISA (1)
- Level sensor (1)
- Lichtstreuungsbasierte Instrumente (1)
- Load modeling (1)
- MEMS (1)
- Machine learning (1)
- Main sensitivity (1)
- Market modeling (1)
- Measurement (1)
- Mechanische Beanspruchung (1)
- Microreactors (1)
- Mohr–Coulomb criterion (1)
- Multi-dimensional wave propagation (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanoparticles (1)
- Nanopartikel (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Natriumhypochlorit (1)
- Natural Language Processing (1)
- Natural language understanding (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Ontologie <Wissensverarbeitung> (1)
- Ontology Engineering (1)
- Open Data (1)
- Open source (1)
- Organophosphorus (1)
- Ostazine Orange (1)
- PFM (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Phenylalanine determination (1)
- Potentiometry (1)
- Process model (1)
- Profile Extraction (1)
- Profile extraction (1)
- Proteine (1)
- Pseudomonas putida (1)
- Quartz crystal nanobalance (QCN) (1)
- Quartz micro balances (1)
- Query learning (1)
- Random variable (1)
- Reaction-diffusion (1)
- Refining (1)
- Relation classification (1)
- Reliability of structures (1)
- Renewable energy sources (1)
- Reproducible research (1)
- Rohr (1)
- Rohrbruch (1)
- Sensitivity (1)
- Sepsis (1)
- Simulation (1)
- Sleep EEG (1)
- Solid amalgam electrodes (1)
- Stahl (1)
- Stochastic programming (1)
- Supraleiter (1)
- Technische Mechanik (1)
- Text Mining (1)
- Text mining (1)
- Time-series (1)
- Tin oxide (1)
- Tobacco mosaic virus (1)
- Torsion (1)
- Torsionsbelastung (1)
- Tragfähigkeit (1)
- Training (1)
- Trustworthy artificial intelligence (1)
- UML (1)
- Unified Modeling Language (1)
- Wafer (1)
- Wasserbrücke (1)
- Wasserstoffperoxid (1)
- Wellen (1)
- Workflow (1)
- Workflow Orchestration (1)
- Zug-Druck-Beanspruchung (1)
- Zug-Druck-Belastung (1)
- acetoin (1)
- activated nanostructured carbon (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- ammonia gas sensors (1)
- amperometric sensor (1)
- antimony doped tin oxide (1)
- autofluorescence-based detection system (1)
- biopotential electrodes (1)
- burst pressure (1)
- burst tests (1)
- capacitive field-effect biosensor (1)
- capillary micro-droplet cell (1)
- carcinogens (1)
- catalytic decomposition (1)
- chemical reduction method (1)
- contractile tension (1)
- cross sensitivity (1)
- cytosolic water diffusion (1)
- date palm tree (1)
- design-by-analysis (1)
- doped metal oxide (1)
- doped silicon (1)
- doping (1)
- electrical capacitance tomography (1)
- electro-migration (1)
- electronic noses dendronized polymers inverted mesa technology (1)
- enzymatic methods (1)
- enzyme immobilisation (1)
- enzyme immobilization (1)
- fenitrothion (1)
- finite element analysis (1)
- flaw (1)
- fluidic (1)
- gas sensor (1)
- gas sensor array (1)
- heater metallisation (1)
- hemoglobin (1)
- hemoglobin dynamics (1)
- high-temperature stability (1)
- humidity (1)
- hydrogel (1)
- hydrogen peroxide (1)
- image sensor (1)
- imaging (1)
- impedance spectroscopy (1)
- ion-selective electrodes (1)
- kontraktile Spannung (1)
- lab-on-a-chip (1)
- lab-on-chip (1)
- layer expansion (1)
- lenslet array (1)
- light scattering analysis (1)
- lightning flash (1)
- limit and shakedown analysis (1)
- limit load (1)
- linear kinematic hardening (1)
- load carrying capacity (1)
- load limit (1)
- lower bound theorem (1)
- magnetic particles (1)
- material shakedown (1)
- matrix method (1)
- mechanical waves (1)
- metal oxide (1)
- microreactor (1)
- microwave generation (1)
- modeling biosensor (1)
- modelling (1)
- modified electrode (1)
- multi-interface measurement (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- nitrogen oxides (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- organic PVC membranes (1)
- pH-based biosensing (1)
- pattern-size reduction (1)
- pipes (1)
- plant scanner (1)
- plasma generated ions (1)
- plastic deformation (1)
- polymer composites (1)
- porous Pt electrode (1)
- principal component (1)
- probabilistic fracture mechanics (1)
- protein (1)
- quantum charging (1)
- reliability (1)
- rhAPC (1)
- screen-printing (1)
- second-order reliability method (1)
- self-aligned patterning (1)
- sensing properties (1)
- sensors (1)
- sterilisation (1)
- subsurface ice research (1)
- subsurface probe (1)
- surface modification (1)
- swift heavy ions (1)
- tension–torsion loading (1)
- thick-film technology (1)
- thin-film microsensors (1)
- vessels (1)
- voltammetry (1)
- wafer-level testing (1)
- water bridge phenomenon (1)
Fields of asymmetric tensors play an important role in many applications such as medical imaging (diffusion tensor magnetic resonance imaging), physics, and civil engineering (for example Cauchy-Green-deformation tensor, strain tensor with local rotations, etc.). However, such asymmetric tensors are usually symmetrized and then further processed. Using this procedure results in a loss of information. A new method for the processing of asymmetric tensor fields is proposed restricting our attention to tensors of second-order given by a 2x2 array or matrix with real entries. This is achieved by a transformation resulting in Hermitian matrices that have an eigendecomposition similar to symmetric matrices. With this new idea numerical results for real-world data arising from a deformation of an object by external forces are given. It is shown that the asymmetric part indeed contains valuable information.
Multi-interface level sensors and new development in monitoring and control of oil separators
(2006)
In the oil industry, huge saving may be made if suitable multi-interface level measurement systems are employed for effectively monitoring crude oil separators and efficient control of their operation. A number of techniques, e.g. externally mounted displacers, differential pressure transmitters and capacitance rod devices, have been developed to measure the separation process with gas, oil, water and other components. Because of the unavailability of suitable multi-interface level measurement systems, oil separators are currently operated by the trial-and-error approach. In this paper some conventional techniques, which have been used for level measurement in industry, and new development are discussed.
Light-stimulated hydrogel actuators with incorporated graphene oxide for microfluidic applications
(2015)
Clearance of blood components and fluid drainage play a crucial role in subarachnoid hemorrhage (SAH) and post hemorrhagic hydrocephalus (PHH). With the involvement of interstitial fluid (ISF) and cerebrospinal fluid (CSF), two pathways for the clearance of fluid and solutes in the brain are proposed. Starting at the level of capillaries, flow of ISF follows along the basement membranes in the walls of cerebral arteries out of the parenchyma to drain into the lymphatics and CSF [1]–[3]. Conversely, it is shown that CSF enters the parenchyma between glial and pial basement membranes of penetrating arteries [4]–[6]. Nevertheless, the involved structures and the contribution of either flow pathway to fluid balance between the subarachnoid space and interstitial space remains controversial. Low frequency oscillations in vascular tone are referred to as vasomotion and corresponding vasomotion waves are modeled as the driving force for flow of ISF out of the parenchyma [7]. Retinal vessel analysis (RVA) allows non-invasive measurement of retinal vessel vasomotion with respect to diameter changes [8]. Thus, the aim of the study is to investigate vasomotion in RVA signals of SAH and PHH patients.
Reliable methods for automatic readability assessment have the potential to impact a variety of fields, ranging from machine translation to self-informed learning. Recently, large language models for the German language (such as GBERT and GPT-2-Wechsel) have become available, allowing to develop Deep Learning based approaches that promise to further improve automatic readability assessment. In this contribution, we studied the ability of ensembles of fine-tuned GBERT and GPT-2-Wechsel models to reliably predict the readability of German sentences. We combined these models with linguistic features and investigated the dependence of prediction performance on ensemble size and composition. Mixed ensembles of GBERT and GPT-2-Wechsel performed better than ensembles of the same size consisting of only GBERT or GPT-2-Wechsel models. Our models were evaluated in the GermEval 2022 Shared Task on Text Complexity Assessment on data of German sentences. On out-of-sample data, our best ensemble achieved a root mean squared error of 0:435.
The vaginal prolapse after hysterectomy (removal of the uterus) is often associated with the prolapse of the vaginal vault, rectum, bladder, urethra or small bowel. Minimally
invasive surgery such as laparoscopic sacrocolpopexy and pectopexy are widely performed for the treatment of the vaginal prolapse with weakly supported vaginal vault after hysterectomy using prosthetic mesh implants to support (or strengthen) lax apical ligaments. Implants of different shape, size and polymers are selected depending on the patient’s anatomy and the surgeon’s preference. In this computational study on pectopexy, DynaMesh®-PRP soft, GYNECARE GYNEMESH® PS Nonabsorbable PROLENE® soft and Ultrapro® are tested in a 3D finite element model of the female pelvic floor. The mesh model is implanted into the extraperitoneal space and sutured to the vaginal stump with a bilateral fixation to the iliopectineal ligament at both sides. Numerical simulations are conducted at rest, after surgery and during Valsalva maneuver with weakened tissues modeled by reduced tissue stiffness. Tissues and prosthetic meshes are modeled as incompressible, isotropic hyperelastic materials. The positions of the organs are calculated with respect to the pubococcygeal line (PCL) for female pelvic floor at rest, after repair and during Valsalva maneuver using the three meshes.
The structure of the female pelvic floor (PF) is an inter-related system of bony pelvis,muscles, pelvic organs, fascias, ligaments, and nerves with multiple functions. Mechanically, thepelvic organ support system are of two types: (I) supporting system of the levator ani (LA) muscle,and (II) the suspension system of the endopelvic fascia condensation [1], [2]. Significantdenervation injury to the pelvic musculature, depolimerization of the collagen fibrils of the softvaginal hammock, cervical ring and ligaments during pregnancy and vaginal delivery weakens thenormal functions of the pelvic floor. Pelvic organ prolapse, incontinence, sexual dysfunction aresome of the dysfunctions which increases progressively with age and menopause due toweakened support system according to the Integral theory [3]. An improved 3D finite elementmodel of the female pelvic floor as shown in Fig. 1 is constructed that: (I) considers the realisticsupport of the organs to the pelvic side walls, (II) employs the improvement of our previous FEmodel [4], [5] along with the patient based geometries, (III) incorporates the realistic anatomy andboundary conditions of the endopelvic (pubocervical and rectovaginal) fascia, and (IV) considersvarying stiffness of the endopelvic fascia in the craniocaudal direction [3]. Several computationsare carried out on the presented computational model with healthy and damaged supportingtissues, and comparisons are made to understand the physiopathology of the female PF disorders.