Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1692)
- Fachbereich Elektrotechnik und Informationstechnik (718)
- IfB - Institut für Bioengineering (624)
- Fachbereich Energietechnik (588)
- INB - Institut für Nano- und Biotechnologien (557)
- Fachbereich Chemie und Biotechnologie (551)
- Fachbereich Luft- und Raumfahrttechnik (497)
- Fachbereich Maschinenbau und Mechatronik (280)
- Fachbereich Wirtschaftswissenschaften (222)
- Solar-Institut Jülich (165)
Language
- English (4929) (remove)
Document Type
- Article (3282)
- Conference Proceeding (1170)
- Part of a Book (195)
- Book (145)
- Doctoral Thesis (31)
- Conference: Meeting Abstract (28)
- Patent (25)
- Other (10)
- Report (10)
- Conference Poster (6)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (12)
- Einspielen <Werkstoff> (10)
- CAD (8)
- civil engineering (8)
- Bauingenieurwesen (7)
- Blitzschutz (6)
- FEM (6)
- Gamification (6)
- Limit analysis (6)
Background: Architectural representation, nurtured by the interaction between design thinking and design action, is inherently multi-layered. However, the representation object cannot always reflect these layers. Therefore, it is claimed that these reflections and layerings can gain visibility through ‘performativity in personal knowledge’, which basically has a performative character. The specific layers of representation produced during the performativity in personal knowledge permit insights about the ‘personal way of designing’ [1]. Therefore, the question, ‘how can these layered drawings be decomposed to understand the personal way of designing’, can be defined as the beginning of the study. On the other hand, performativity in personal knowledge in architectural design is handled through the relationship between explicit and tacit knowledge and representational and non-representational theory. To discuss the practical dimension of these theoretical relations, Zvi Hecker's drawing of the Heinz-Galinski-School is examined as an example. The study aims to understand the relationships between the layers by decomposing a layered drawing analytically in order to exemplify personal ways of designing.
Methods: The study is based on qualitative research methodologies. First, a model has been formed through theoretical readings to discuss the performativity in personal knowledge. This model is used to understand the layered representations and to research the personal way of designing. Thus, one drawing of Hecker’s Heinz-Galinski-School project is chosen. Second, its layers are decomposed to detect and analyze diverse objects, which hint to different types of design tools and their application. Third, Zvi Hecker’s statements of the design process are explained through the interview data [2] and other sources. The obtained data are compared with each other.
Results: By decomposing the drawing, eleven layers are defined. These layers are used to understand the relation between the design idea and its representation. They can also be thought of as a reading system. In other words, a method to discuss Hecker’s performativity in personal knowledge is developed. Furthermore, the layers and their interconnections are described in relation to Zvi Hecker’s personal way of designing.
Conclusions: It can be said that layered representations, which are associated with the multilayered structure of performativity in personal knowledge, form the personal way of designing.
A second-order L-stable exponential time-differencing (ETD) method is developed by combining an ETD scheme with approximating the matrix exponentials by rational functions having real distinct poles (RDP), together with a dimensional splitting integrating factor technique. A variety of non-linear reaction-diffusion equations in two and three dimensions with either Dirichlet, Neumann, or periodic boundary conditions are solved with this scheme and shown to outperform a variety of other second-order implicit-explicit schemes. An additional performance boost is gained through further use of basic parallelization techniques.
Mechanical forces/tensile stresses are critical determinants of cellular growth, differentiation and migration patterns in health and disease. The innovative “CellDrum technology” was designed for measuring mechanical tensile stress of cultured cell monolayers/thin tissue constructs routinely. These are cultivated on very thin silicone membranes in the so-called CellDrum. The cell layers adhere firmly to the membrane and thus transmit the cell forces generated. A CellDrum consists of a cylinder which is sealed from below with a 4 μm thick, biocompatible, functionalized silicone membrane. The weight of cell culture medium bulbs the membrane out downwards. Membrane indentation is measured. When cells contract due to drug action, membrane, cells and medium are lifted upwards. The induced indentation changes allow for lateral drug induced mechanical tension quantification of the micro-tissues. With hiPS-induced (human) Cardiomyocytes (CM) the CellDrum opens new perspectives of individualized cardiac drug testing. Here, monolayers of self-beating hiPS-CMs were grown in CellDrums. Rhythmic contractions of the hiPS-cells induce membrane up-and-down deflections. The recorded cycles allow for single beat amplitude, single beat duration, integration of the single beat amplitude over the beat time and frequency analysis. Dose effects of agonists and antagonists acting on Ca2+ channels were sensitively and highly reproducibly observed. Data were consistent with published reference data as far as they were available. The combination of the CellDrum technology with hiPS-Cardiomyocytes offers a fast, facile and precise system for pharmacological and toxicological studies. It allows new preclinical basic as well as applied research in pharmacolgy and toxicology.
The invention pertains to a CellDrum electrode arrangement for measuring mechanical stress, comprising a mechanical holder (1 ) and a non-conductive membrane (4), whereby the membrane (4) is at least partially fixed at its circumference to the mechanical holder (1), keeping it in place when the membrane (4) may bend due to forces acting on the membrane (4), the mechanical holder (1) and the membrane (4) forming a container, whereby the membrane (1) within the container comprises an cell- membrane compound layer or biological material (3) adhered to the deformable membrane 4 which in response to stimulation by an agent may exert mechanical stress to the membrane (4) such that the membrane bending stage changes whereby the container may be filled with an electrolyte, whereby an electric contact (2) is arranged allowing to contact said electrolyte when filled into to the container, whereby within a predefined geometry to the fixing of the membrane (4) an electrode (7) is arranged, whereby the electrode (7) is electrically insulated with respect to the electric contact (2) as well as said electrolyte, whereby mechanical stress due to an agent may be measured as a change in capacitance.