Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1934)
- Fachbereich Elektrotechnik und Informationstechnik (1150)
- Fachbereich Wirtschaftswissenschaften (1121)
- Fachbereich Energietechnik (1067)
- Fachbereich Chemie und Biotechnologie (897)
- Fachbereich Maschinenbau und Mechatronik (811)
- Fachbereich Luft- und Raumfahrttechnik (769)
- Fachbereich Bauingenieurwesen (664)
- IfB - Institut für Bioengineering (627)
- INB - Institut für Nano- und Biotechnologien (586)
Has Fulltext
- no (9329) (remove)
Language
Document Type
- Article (5531)
- Conference Proceeding (1421)
- Book (1062)
- Part of a Book (567)
- Patent (177)
- Bachelor Thesis (169)
- Report (83)
- Doctoral Thesis (81)
- Conference: Meeting Abstract (76)
- Other (67)
Keywords
- Illustration (10)
- Nachhaltigkeit (10)
- Corporate Design (9)
- Erscheinungsbild (8)
- Gamification (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Deutschland (6)
- Digitalisierung (6)
This paper aims to evaluate the formability of tailor welded blanks of dual phase (DP600)/transformation induced plasticity (TRIP700) steel sheets. In this work, bead on plate butt joints of 2·5 mm DP600 and 1·2 mm TRIP700 steel sheets were performed using CO2 laser beam welding. Microhardness measurements and transverse tensile testing were carried out to characterise the welds. The formability of base metals and welds were investigated by standard Erichsen test. In a perpendicular tensile test to the weld line, all specimens were fractured at the TRIP base metal, and the strengths were somewhat higher than those of base metal. There was a significant reduction in formability caused by welding of the DP600/TRIP700 steel sheets, and the formability increased with increasing welding speed.
The purpose of the current study was to examine the reproducibility of fascicle length and pennation angle of gastrocnemius medialis while human walking. To the best of our knowledge, this is the first study of the reproducibility of fascicle length and pennation angle of gastrocnemius medialis in vivo during human gait. Twelve males performed 10 gait trials on a treadmill, in 2 separate days. B-mode ultrasonography, with the ultrasound probe firmly adjusted in the transverse and frontal planes using a special cast, was used to measure the fascicle length and the pennation angle of the gastrocnemius medialis (GM). A Vicon 624 system with three cameras operating at 120 Hz was also used to record the ankle and knee joint angles. The results showed that measurements of fascicle length and pennation angle showed high reproducibility during the gait cycle, both within the same day and between different days. Moreover, the root mean square differences between the repeated waveforms of both variables were very small, compared with their ranges (fascicle length: RMS = ∼3 mm, range: 38–63 mm; pennation angle: RMS = ∼1.5°, range: 22–32°). However, their reproducibility was lower compared to the joint angles. It was found that representative data have to be derived by a wide number of gait trials (fascicle length ∼six trials, pennation angle more than 10 trials), to assure the reliability of the fascicle length and pennation angle in human gait.
Thin films of poly(ethyleneterephthalate) [PET]were exposed to radiation dose ranging from 10 to 30 kGy by using gamma rays in the range 12.8-177.8 MGy using swift light ions of hydrogen. There was no effect of the radiation dose on the optical behaviour of PET as a result of exposure to radiation dose up to 30 kGy brought about by gamma rays but a significant decrease in the optical band gap values was observed when PET was exposed to swift light ions of hydrogen. The data obtained are discussed in terms of optical studies carried out on PET using swift heavy ions.
INNOTRAP - innovative Rußfilter für LKW-Dieselmotoren : Abschlussbericht Förderkennzeichen 16IN0313
(2009)
In der Abschlussarbeit „FILOS“ wurde in Zusammenarbeit mit dem Fraunhofer-Institut für Lasertechnik (ILT) ein Front-End für das laserbasierte Osteotom STELLA entwickelt. STELLA soll Kraniotomie (das Eröffnen des Schädels) im wachen Zustand ermöglichen und erfordert eine benutzerfreundliche Bedienungsplattform sowie ein funktionales und ästhetisches Design. Das Ziel von „FILOS“ war es, ein Gehäuse zu entwerfen, das den medizinischen Anforderungen entspricht, und ein Bedienkonzept zu entwickeln, dass die Akzeptanz bei Patient:innen und Anwender:innen fördert. Durch Expert:innen-Interviews mit Neurochirurg:innen und enge Zusammenarbeit mit dem ILT wurde ein durchdachtes Design entwickelt. Dieses soll den Anforderungen der Anwender:innen gerecht werden, das zukünftige Operationssystem repräsentieren und somit einen Mehrwert in der Medizin schaffen.
For performing point-of-care molecular diagnostics, magnetic immunoassays constitute a promising alternative to established enzyme-linked immunosorbent assays (ELISA) because they are fast, robust and sensitive. Simultaneous detection of multiple biomolecular targets from one body fluid sample is desired. The aim of this work is to show that multiplex magnetic immunodetection based on magnetic frequency mixing by means of modular immunofiltration columns prepared for different targets is feasible. By calculations of the magnetic response signal, the required spacing between the modules was determined. Immunofiltration columns were manufactured by 3D printing and antibody immobilization was performed in a batch approach. It was shown experimentally that two different target molecules in a sample solution could be individually detected in a single assaying step with magnetic measurements of the corresponding immobilization filters. The arrangement order of the filters and of a negative control did not influence the results. Thus, a simple and reliable approach to multi-target magnetic immunodetection was demonstrated.