Refine
Year of publication
- 2010 (332) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (69)
- Fachbereich Wirtschaftswissenschaften (41)
- IfB - Institut für Bioengineering (36)
- Fachbereich Chemie und Biotechnologie (35)
- Fachbereich Elektrotechnik und Informationstechnik (35)
- Fachbereich Energietechnik (35)
- Fachbereich Maschinenbau und Mechatronik (31)
- Fachbereich Luft- und Raumfahrttechnik (24)
- Fachbereich Bauingenieurwesen (23)
- INB - Institut für Nano- und Biotechnologien (22)
Has Fulltext
- no (332) (remove)
Document Type
- Article (175)
- Conference Proceeding (68)
- Book (37)
- Part of a Book (20)
- Conference: Meeting Abstract (13)
- Patent (7)
- Report (4)
- Doctoral Thesis (2)
- Other (2)
- Contribution to a Periodical (1)
Keywords
- Geschichte (2)
- avalanche (2)
- humans (2)
- Adsorbentien (1)
- Cardiovascular MRI (1)
- Cardiovascular Magnetic Resonance (1)
- Commercial Vehicle (1)
- Common Rail Injection System (1)
- Diesel Engine (1)
- Enzymatischer Ligninabbau (1)
The objectives of the present work are to characterize the Gas Metal Arc Welding process of DP 600 sheet steel and to summarize the modelling techniques. The time-temperature evolution during the welding cycle was measured experimentally and modelled with the softwaretool SimWeld. To model the phase transformations during the welding cycle dilatometer tests were done to quantify the parameters for phase field modelling by MICRESS®. The important input parameters are interface mobility, nucleation density, etc. A contribution was made to include austenite to bainite transformation in MICRESS®. This is useful to predict the microstructure in the fast cooling segments. The phase transformation model is capable to predict the microstructure along the heating and cooling cycles of welding. Tensile tests have shown the evidence of failure at the heat affected zone, which has the ferrite-tempered martensite microstructure.
Molke fällt im Rahmen der Käseherstellung allein in Deutschland in Mengen von über 11 Mio. Tonnen jährlich an. Dieses Nebenprodukt wurde trotz seines Reichtums an Milchzucker und Proteinen lange Zeit kaum industriell weiterverarbeitet und stellte ein bedeutendes Problem bei der Abwasserreinigung dar. Derzeit kommen meist kosten- und reinigungsintensive Membranfiltrationsverfahren bei der Auftrennung von Molke in ihre Hauptkomponenten Lactose und Molkenprotein zum Einsatz. Die Produkte finden vorwiegend in der Nahrungsmittelindustrie Anwendung als Süßungsmittel, Proteinzusatz oder Texturbildner. Die Mehrheit des Proteins wird dabei als Konzentrat bzw. Proteinpulver verarbeitet. Wegen der antibakteriellen, antiviralen und weiteren wertvollen physiologischen Eigenschaften der Molkeproteine stellt eine weitere Aufreinigung der einzelnen Molkeproteine für die pharmazeutische Industrie einen naheliegenden zusätzlichen Wertschöpfungsschritt dar. In Kooperation mit der Süd Chemie AG wurde damit begonnen, ein Verfahren zu entwickeln, das kostengünstige mineralische Adsorbentien verwendet. Bisher konnte die Abtrennung von Lactose von den Molkenproteinen aus verdünntem Molkekonzentrat in einem Verfahrensschritt ohne Vorbehandlung des Rohstoffs erfolgreich realisiert werden. Aktuelle Arbeiten beschäftigen sich mit der Verbesserung der Proteinbindekapazitätund chromatographischen Proteinauftrennung sowie dem Upscaling zum direkten Einsatz von Molkekonzentrat ohne Vorverdünnung.
Comparison of Intravenous Immunoglobulins for Naturally Occurring Autoantibodies against Amyloid-β
(2010)
As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to distortions and mistriggering increases and with it the motivation for a cardiac triggering alternative. Hence, this study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects at 1.5T and 3.0T.
Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT’s performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)%). Conclusions: ACT’s intrinsic insensitivity to interference from electromagnetic fields renders
The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocytes. Cells were grown either within flexible, circular collagen gels or as monolayer on top of respective 1-mum thin silicone membranes. Membrane and cells were bulged outwards by air pressure. This biaxial strain distribution is rather similar the beating, blood-filled heart. The setup allowed presetting the mechanical residual stress level externally by adjusting the centre deflection, thus, mimicking hypertension in vitro. Tension was measured as oscillating differential pressure change between chamber and environment. A 0.5-mm thick collagen-cardiac myocyte tissue construct induced after 2 days of culturing (initial cell density 2 x 10(4) cells/ml), a mechanical tension of 1.62 +/- 0.17 microN/mm(2). Mechanical load is an important growth regulator in the developing heart, and the orientation and alignment of cardiomyocytes is stress sensitive. Therefore, it was necessary to develop the CellDrum technology with its biaxial stress-strain distribution and defined mechanical boundary conditions. Cells were exposed to strain in two directions, radially and circumferentially, which is similar to biaxial loading in real heart tissues. Thus, from a biomechanical point of view, the system is preferable to previous setups based on uniaxial stretching.
Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants
(2010)
Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements.