Refine
Year of publication
- 2012 (333) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (72)
- Fachbereich Wirtschaftswissenschaften (42)
- Fachbereich Elektrotechnik und Informationstechnik (41)
- Fachbereich Chemie und Biotechnologie (40)
- INB - Institut für Nano- und Biotechnologien (32)
- IfB - Institut für Bioengineering (31)
- Fachbereich Bauingenieurwesen (30)
- Fachbereich Maschinenbau und Mechatronik (29)
- Fachbereich Energietechnik (20)
- Solar-Institut Jülich (15)
Document Type
- Article (130)
- Conference Proceeding (89)
- Part of a Book (36)
- Book (26)
- Conference: Meeting Abstract (17)
- Patent (12)
- Part of a Periodical (9)
- Doctoral Thesis (7)
- Report (4)
- Habilitation (1)
Keywords
- Elektromobilität (7)
- Elektrofahrzeug (5)
- Energieversorgungsnetz (5)
- Kraftfahrzeugelektronik (5)
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (2)
- Elektromobilität; Elektrofahrzeug; Energieversorungsnetz; Kraftfahrzeugtechnik (2)
- (Bio)degradation (1)
- 3. EU Legislativpaket (1)
- 802.15.4 (1)
- Acceleration (1)
- Adsorption (1)
- Afterload (1)
- Alginate beads (1)
- Anastomotic leakage (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Avalanche (1)
- Bank-issued Warrants (1)
- Bio-Sensors (1)
- Biosensor (1)
- Bluetooth (1)
- Borehole heat exchanger (1)
- Calorimetric gas sensor (1)
- Cell permeability (1)
- CellDrum (1)
- Cellular force (1)
- Central receiver system (1)
- Chemical imaging sensor (1)
- Circular Dichroism (1)
- Cloud Computing (1)
- Cloud Service Broker (1)
- Compliance (1)
- Concentrated solar collector (1)
- Consensus (1)
- Contractile tension (1)
- Contractility (1)
- C–V method (1)
- Decomposition (1)
- Detergent protease (1)
- Discourse ethics (1)
- Disposition Effect (1)
- Distributed Control Systems, (1)
- Eisschicht (1)
- Elemental (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Energiewirtschaft (1)
- Esophageal Doppler monitor (1)
- Extracellular enzymes (1)
- FH Aachen (1)
- Fachhochschule Aachen (1)
- Field-effect sensor (1)
- Finite differences (1)
- Finite element modelling (1)
- Force (1)
- Forschungsbericht (1)
- Freeze–thaw process (1)
- Fresnel collector (1)
- Fußball (1)
- Gleichspannungswandler (1)
- Graduiertentagung (1)
- Grid Computing (1)
- Guerrillawerbung (1)
- Heat transport (1)
- Hydrogen peroxide (1)
- Hypersecretion (1)
- IP-based networks (1)
- Impedance spectroscopy (1)
- Individual Investors (1)
- IndraMotion (1)
- Industrial Automation Technology, (1)
- Kinetic energy (1)
- Konsumgesellschaft (1)
- Künstlerisches Handeln (1)
- LAPS (1)
- Light-addressable potentiometric sensor (1)
- Lipopolysaccharide (1)
- Liver (1)
- Low-field NMR (1)
- MATLAB , MLPI , Motion control , Open Core , industrial drives , rapid control prototypin , sercos automation bus (1)
- Marker-free mutagenesis (1)
- Medienforschung (1)
- Molkeproteine (1)
- Motion-Logic System (1)
- NGN (1)
- NMR exchange relaxometry (1)
- NONOate (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanotechnologie (1)
- Negative Feedback Trading (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Numerical linear algebra (1)
- Optical and thermal analysis (1)
- Organic light-emitting diode display (1)
- Ownership Unbundling (1)
- PIV (1)
- PROFINET (1)
- Parasitäre Strategie (1)
- Politische Kunst (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Requirements prioritization (1)
- Requirements relations (1)
- Research Report (1)
- Robotik (1)
- SLM (1)
- SPS (1)
- ScaLAPACK (1)
- Schienbeinschoner (1)
- Selektives Laser Schmelzen (1)
- Silber (1)
- Snow (1)
- Solar concentration (1)
- Sonde (1)
- Speicherprogrammierte Steuerung (1)
- Spleen (1)
- Stenotrophomonas maltophilia (1)
- Sterilisation process (1)
- Stromnetz (1)
- Surgical staplers (1)
- Tool support (1)
- Trading Behavior (1)
- Uracil-phosphoribosyltransferase (1)
- VOF (1)
- Variable height stapler design (1)
- Velocity (1)
- Volume status (1)
- Wireless Networks (1)
- Workflow (1)
- Workflow Orchestration (1)
- Wärmeübertragung (1)
- architectural design process (1)
- brachytherapy (1)
- dam-break (1)
- design theory (1)
- drag force (1)
- eigensolvers (1)
- incontinence (1)
- instruments (1)
- interdisciplinarity (1)
- methodologies (1)
- mobile robots (1)
- next generation network (1)
- numerical model (1)
- performance analysis (1)
- physical model (1)
- product bundling (1)
- prostate cancer (1)
- prostatectomy (1)
- quality of life (1)
- subglacial aquatic ecosystems (1)
- subsurface ice (1)
- telecommunication (1)
- Übertragungsnetz (1)
The highly polymorphic human cytochrome P450 2D6 enzyme is involved in the metabolism of up to 25% of all marketed drugs and accounts for significant individual differences in response to CYP2D6 substrates. Because of the differences in the multiplicity and substrate specificity of CYP2D family members among species, it is difficult to predict pathways of human CYP2D6-dependent drug metabolism on the basis of animal studies. To create animal models that reflect the human situation more closely and that allow an in vivo assessment of the consequences of differential CYP2D6 drug metabolism, we have developed a novel straightforward approach to delete the entire murine Cyp2d gene cluster and replace it with allelic variants of human CYP2D6. By using this approach, we have generated mouse lines expressing the two frequent human protein isoforms CYP2D6.1 and CYP2D6.2 and an as yet undescribed variant of this enzyme, as well as a Cyp2d cluster knockout mouse. We demonstrate that the various transgenic mouse lines cover a wide spectrum of different human CYP2D6 metabolizer phenotypes. The novel humanization strategy described here provides a robust approach for the expression of different CYP2D6 allelic variants in transgenic mice and thus can help to evaluate potential CYP2D6-dependent interindividual differences in drug response in the context of personalized medicine.
Cell-based sensors for the detection of gases have long been underrepresented, due to the cellular requirement of being cultured in a liquid environment. In this work we established a cell-based gas biosensor for the detection of toxic substances in air, by adapting a commercial sensor chip (Bionas®), previously used for the measurement of pollutants in liquids. Cells of the respiratory tract (A549, RPMI 2650, V79), which survive at a gas phase in a natural context, are used as biological receptors. The physiological cell parameters acidification, respiration and morphology are continuously monitored in parallel. Ammonia was used as a highly water-soluble model gas to test the feasibility of the sensor system. Infrared measurements confirmed the sufficiency of the medium draining method. This sensor system provides a basis for many sensor applications such as environmental monitoring, building technology and public security.
A magnetic resonance tomography (MRT) apparatus (1) for the examination of a body (14) comprises parameter acquisition devices (13) for the acquisition of cardiovascular parameters of the body (14) and a control device (15) in communication with the parameter acquisition devices (13) for synchronizing the imaging, wherein the control device (15) is adapted to analyse the data of at least two parameter acquisition devices (13) and to output a control signal based on the analysis.
Proceedings of the 2nd Humboldt Kolleg, Hammamet, Tunisia Organizer: Alexander von Humboldt Stiftung, Germany. pdf 184 p. Welcome Address Dear Participants, Welcome to the 2nd Humboldt Kolleg in “Nanoscale Science and Technology” (NS&T’12) in Tunisia, sponsored by the "Alexander von Humboldt" foundation. The NS&T’12 multidisciplinary scientific program includes seven "hot" topics dealing with "Nanoscale Science and Technology" covering basic and application-oriented research as well as industrial (market) aspects: - Molecular Biophyics, Spectroscopy Techniques, Imaging Microscopy - Nanomaterials Synthesis for Medicine and Bio-chemical Sensors - Nanostructures, Semiconductors, Photonics and Nanodevices - New Technologies in Market Industry - Environment, Electro-chemistry, Bio-polymers and Fuel Cells - Nanomaterials, Photovoltaic, Modelling, Quantum Physics - Microelectronics, Sensors Networks and Embedded Systems We are deeply indebted to all members of the Scientific Committee and General Chairs for joint Sessions and to all speakers and chairmen, who have dedicated invaluable time and efforts for the realization of this event. On behalf of the Organizing Committee, we are cordially inviting you to join the conference and hope that your stay will be fruitful, rewarding and enjoyable. Prof. Dr. Michael J. Schöning, Prof. Dr. Adnane Abdelghani
Suburethral slings as well as different meshes are widely used treating stress urinary incontinence and prolaps in women. With the development of MiniSlings and special meshes using less alloplastic material anchorage systems become more important to keep devices in place and to put some tension especially on the MiniSlings. To date, there are many different systems of MiniSlings of different companies on the market which differ in the structure of the used meshes and anchors. A new objective measurement method to compare different properties of MiniSling systems (mesh and anchor) is presented in this article. Ballistic gelatine acts as soft tissue surrogate. Significant differences in parameters like pull-out strength of anchors or shrinkage of meshes under loading conditions have been determined. The form and size of the anchors as well as the structural stability of the meshes are decisive for a proper integration. The tested anchorings sytems showed markedly different mechanical function at their respective load bearing capacity. As the stable fixation of the device in tissue is a prerequisite for a permanet reinforcement, the proposed test system permits further optimisation of anchor and mesh devices to improve the success of the surgical treatment
A variety of transition metals, e.g., copper, zinc, cadmium, lead, etc. are widely used in industry as components for wires, coatings, alloys, batteries, paints and so on. The inevitable presence of transition metals in industrial processes implies the ambition of developing a proper analytical technique for their adequate monitoring. Most of these elements, especially lead and cadmium, are acutely toxic for biological organisms. Quantitative determination of these metals at low activity levels in different environmental and industrial samples is therefore a vital task. A promising approach to achieve an at-side or on-line monitoring on a miniaturized and cost efficient way is the combination of a common potentiometric sensor array with heavy metal-sensitive thin-film materials, like chalcogenide glasses and polymeric materials, respectively.
Die fermentative Verwertung von Rohglycerin setzt je nach Herstellungsmethode und Produktionsorganismus eine Vorbehandlung des Glycerins zur Entfernung von Produktinhibitoren voraus. Durch den Einsatz von Hydrotalcit-Adsorbern können die im Rohglycerin enthaltenen Fettsäuren entfernt werden. Durch diese einfache Aufarbeitungsmethode ist ein mit reinem Glycerin vergleichbarer Umsatz von stark mit Fettsäuren verunreinigtem Rohglycerin zu 1,3-Propandiol (PDO) möglich. Die durch den Hydrotalcit gebundenen Fettsäuren lassen sich mit einem Ethanol-Wasser-Gemisch eluieren. Somit kann der Adsorber regeneriert und die Fettsäuren wieder der Wertschöpfungskette zugeführt werden. Im Fed-Batch-Experiment kann mit C. diolis eine PDO-Konzentration von über 50 g L⁻¹ unter Verwendung des aufgereinigten Rohglycerins erzielt werden. In der industriellen Produktion wird PDO momentan destillativ aufgearbeitet. Ein adsorptives Aufarbeitungsverfahren kann den Energiebedarf des Herstellungsprozesses drastisch senken. Auf der Suche nach einem geeigneten Material wurde ein Adsorberscreening in Bezug auf die Bindungseigenschaften durchgeführt. Mit einem b-Zeolith der Firma Süd ChemieAG konnte bisher die höchste Beladung im Modellsystem von 120 mg PDO/gAdsorber erreicht werden.
Thin films of poly(ethyleneterephthalate) [PET]were exposed to radiation dose ranging from 10 to 30 kGy by using gamma rays in the range 12.8-177.8 MGy using swift light ions of hydrogen. There was no effect of the radiation dose on the optical behaviour of PET as a result of exposure to radiation dose up to 30 kGy brought about by gamma rays but a significant decrease in the optical band gap values was observed when PET was exposed to swift light ions of hydrogen. The data obtained are discussed in terms of optical studies carried out on PET using swift heavy ions.
Optimierung der selektiven Aufarbeitung von Proteinen mit Aptamer-funktionalisierten Magnetpartikeln
(2012)
Die Herstellung pharmakologisch relevanter Proteine durch Mikroorganismen führt eine mehrstufige Aufarbeitung mit sich. Durch die Verwendung von Aptameren, kurzen einzelsträngigen DNA- oder RNA-Oligonukleotiden immobilisiert auf funktionalisierten, wiederverwendbaren Magnetpartikeln, können mehrere dieser Abtrennungsoperationen kombiniert und damit die Prozesskosten minimiert werden. Aufgrund der definierten dreidimensionalen Struktur können Aptamere kleine organische Moleküle hochspezifisch binden. Im vorgestellten Projekt wird die Aufarbeitung von His6-GFP als Modellprotein mithilfe der mit Aptamer funktionalisierten Magnetpartikel durchgeführt. In bisherigen Versuchen wurde die Bindung von Aptameren auf den magnetischen Partikeln sowie die Bindung des Modellproteins GFP auf den Partikeln optimiert. Des Weiteren wurden mehrere Strategien zur Elution des GFPs von den Partikeln verfolgt, um den Proteinertrag zu maximieren und die Partikel rezyklieren zu können. Die Untersuchung unspezifischer Bindungen von Zelltrümmern und Proteinen an die Magnetpartikel wurde mithilfe eines konfokalen Laser-Scanning-Mikroskops durchgeführt.
Im vom BMELV/FNR geförderten SynRg-Projekt wurde unter anderem Rapsschrot untersucht, um Polyphenole zu isolieren und aufzureinigen. Diese sollen anschließend als Basisbausteine für Polymere dienen und ihnen neuartige Eigenschaften verleihen. Derzeit wird an der Polyphenolextraktion gearbeitet, da bei organischen oder wässrigen Extraktionsprozessen überwiegend Sinapin, ein Cholinester der Sinapinsäure, vorliegt und dieses nicht für die Polymerbildung eingesetzt werden kann. Für die im Fokus stehende Sinapinsäure wird deshalb eine simultane Extraktion und enzymatische oder chemische Hydrolyse von Sinapin zu Sinapinsäure durchgeführt. Durch die Hydrolyse konnte die Sinapinsäureausbeute bereits um den Faktor 6,2 auf 15,8 mg g⁻¹ gegenüber einer reinwässrigen Extraktion gesteigert werden. Für die Aufreinigung des an Sinapinsäure reichen Extrakts erfolgt anschließend ein adsorptiver Aufarbeitungsschritt, bei dem Zeolithe zum Einsatz kommen. Mit diesem Material ist es möglich, die Sinapinsäure quantitativ zu adsorbieren und später mit 70 %igem Ethanol bei 60 °C zu desorbieren. Bei den Adsorbern handelt es sich um b-Zeolithe von der Süd-Chemie AG.
Generally, the quality of a weld joint is directly influenced by the welding input parameter settings. Selection of proper process parameters is important to obtain the desired weld bead profile and quality. In this research work, numerical and graphical optimization techniques of the CO2 laser beam welding of dual phase (DP600)/transformation induced plasticity (TRIP700) steel sheets were carried out using response surface methodology (RSM) based on Box–Behnken design. The procedure was established to improve the weld quality, increase the productivity and minimize the total operation cost by considering the welding parameters range of laser power (2–2.2 kW), welding speed (40–50 mm/s) and focus position (−1 to 0 mm). It was found that, RSM can be considered as a powerful tool in experimental welding optimization, even when the experimenter does not have a model for the process. Strong, efficient and low cost weld joints could be achieved using the optimum welding conditions.
In this study we observed courses of micturition symptoms and differentiated degrees of symptoms for each point in time while also considering the impact of bothersomeness. Our data show that not only significantly more patients who have undergone BT suffer from OAB than those who have undergone RP, but also that those affected show significantly higher values for severity of OAB symptoms throughout the whole observation period of 36 months. Our data analysis further shows that variability of OAB symptoms as well as fluctuation of severity of OAB symptoms vary to a significantly higher degree after BT than after RP. Looking only at mean figures at a given point in time clearly underestimates the underlying problem. This fact is not reflected in the literature.