Article
Refine
Year of publication
- 2024 (32)
- 2023 (64)
- 2022 (78)
- 2021 (86)
- 2020 (101)
- 2019 (95)
- 2018 (84)
- 2017 (72)
- 2016 (78)
- 2015 (83)
- 2014 (93)
- 2013 (97)
- 2012 (82)
- 2011 (130)
- 2010 (121)
- 2009 (121)
- 2008 (103)
- 2007 (94)
- 2006 (86)
- 2005 (99)
- 2004 (131)
- 2003 (74)
- 2002 (92)
- 2001 (88)
- 2000 (84)
- 1999 (88)
- 1998 (82)
- 1997 (79)
- 1996 (70)
- 1995 (68)
- 1994 (76)
- 1993 (51)
- 1992 (48)
- 1991 (25)
- 1990 (35)
- 1989 (38)
- 1988 (54)
- 1987 (32)
- 1986 (18)
- 1985 (32)
- 1984 (18)
- 1983 (17)
- 1982 (26)
- 1981 (18)
- 1980 (35)
- 1979 (23)
- 1978 (30)
- 1977 (14)
- 1976 (13)
- 1975 (10)
- 1974 (3)
- 1972 (2)
- 1971 (1)
- 1968 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1356)
- INB - Institut für Nano- und Biotechnologien (503)
- Fachbereich Chemie und Biotechnologie (472)
- Fachbereich Elektrotechnik und Informationstechnik (414)
- IfB - Institut für Bioengineering (409)
- Fachbereich Energietechnik (361)
- Fachbereich Luft- und Raumfahrttechnik (253)
- Fachbereich Maschinenbau und Mechatronik (148)
- Fachbereich Wirtschaftswissenschaften (116)
- Fachbereich Bauingenieurwesen (69)
Language
- English (3275) (remove)
Document Type
- Article (3275) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- biosensors (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
Purpose
To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T.
Methods
The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study.
Results
Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly.
Conclusion
The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T.
Modulation of muscle-tendon interaction in the human triceps surae during an energy dissipation task
(2017)
Molecular Modeling Approach to the Prediction of Mechanical Properties of Silica-Reinforced Rubbers
(2014)
Recently, we have suggested a nanomechanical model for dissipative loss in filled elastomer networks in the context of the Payne effect. The mechanism is based on a total interfiller particle force exhibiting an intermittent loop, due to the combination of short-range repulsion and dispersion forces with a long-range elastic attraction. The sum of these forces leads, under external strain, to a spontaneous instability of “bonds” between the aggregates in a filler network and attendant energy dissipation. Here, we use molecular dynamics simulations to obtain chemically realistic forces between surface modified silica particles. The latter are combined with the above model to estimate the loss modulus and the low strain storage modulus in elastomers containing the aforementioned filler-compatibilizer systems. The model is compared to experimental dynamic moduli of silica filled rubbers. We find good agreement between the model predictions and the experiments as function of the compatibilizer's molecular structure and its bulk concentration.
Molecular-genetic identification of emerged novel invasive pathogens of Asiatic Elm Ulmus pumila L
(2014)
The dwarf elm Ulmus pumila L. (Ulmaceae) is one of indigenous species of flora in Kazakhstan and forms a basis of dendroflora in virtually all settlements of the region. In the past decade, multiple outbreaks of previously unknown diseases of the small-leaved elm have been registered. In our study, by the molecular-genetic analysis it was found that the pathogens responsible for the outbreaks are microfungi belonging to the genus Fusarium – F. solani and F. oxysporum. The nucleotide sequences (ITS regions) isolated from the diseased trees showed very high similarity with the GenBank control numbers EU625403.1 and FJ478128.1 (100.0 and 99.0 % respectively). Oncoming research will focus on the search of natural microbial antagonists of the discovered phytopathogens.
Cell-based sensors for the detection of gases have long been underrepresented, due to the cellular requirement of being cultured in a liquid environment. In this work we established a cell-based gas biosensor for the detection of toxic substances in air, by adapting a commercial sensor chip (Bionas®), previously used for the measurement of pollutants in liquids. Cells of the respiratory tract (A549, RPMI 2650, V79), which survive at a gas phase in a natural context, are used as biological receptors. The physiological cell parameters acidification, respiration and morphology are continuously monitored in parallel. Ammonia was used as a highly water-soluble model gas to test the feasibility of the sensor system. Infrared measurements confirmed the sufficiency of the medium draining method. This sensor system provides a basis for many sensor applications such as environmental monitoring, building technology and public security.
Designing novel or optimizing existing biodegradable polymers for biomedical applications requires numerous tests on the effect of substances on the degradation process. In the present work, polymer-modified electrolyte–insulator–semiconductor (PMEIS) sensors have been applied for monitoring an enzymatically catalyzed degradation of polymers for the first time. The thin films of biodegradable polymer poly(d,l-lactic acid) and enzyme lipase were used as a model system. During degradation, the sensors were read-out by means of impedance spectroscopy. In order to interpret the data obtained from impedance measurements, an electrical equivalent circuit model was developed. In addition, morphological investigations of the polymer surface have been performed by means of in situ atomic force microscopy. The sensor signal change, which reflects the progress of degradation, indicates an accelerated degradation in the presence of the enzyme compared to hydrolysis in neutral pH buffer media. The degradation rate increases with increasing enzyme concentration. The obtained results demonstrate the potential of PMEIS sensors as a very promising tool for in situ and real-time monitoring of degradation of polymers.
In the present work, a novel method for monitoring sterilisation processes with gaseous H2O2 in combination with heat activation by means of a specially designed calorimetric gas sensor was evaluated. Therefore, the sterilisation process was extensively studied by using test specimens inoculated with Bacillus atrophaeus spores in order to identify the most influencing process factors on its microbicidal effectiveness. Besides the contact time of the test specimens with gaseous H2O2 varied between 0.2 and 0.5 s, the present H2O2 concentration in a range from 0 to 8% v/v (volume percent) had a strong influence on the microbicidal effectiveness, whereas the change of the vaporiser temperature, gas flow and humidity were almost negligible. Furthermore, a calorimetric H2O2 gas sensor was characterised in the sterilisation process with gaseous H2O2 in a wide range of parameter settings, wherein the measurement signal has shown a linear response against the H2O2 concentration with a sensitivity of 4.75 °C/(% v/v). In a final step, a correlation model by matching the measurement signal of the gas sensor with the microbial inactivation kinetics was established that demonstrates its suitability as an efficient method for validating the microbicidal effectiveness of sterilisation processes with gaseous H2O2.