Refine
Year of publication
- 2024 (25)
- 2023 (101)
- 2022 (132)
- 2021 (145)
- 2020 (157)
- 2019 (192)
- 2018 (168)
- 2017 (154)
- 2016 (154)
- 2015 (176)
- 2014 (166)
- 2013 (171)
- 2012 (154)
- 2011 (184)
- 2010 (179)
- 2009 (185)
- 2008 (155)
- 2007 (149)
- 2006 (160)
- 2005 (130)
- 2004 (161)
- 2003 (106)
- 2002 (130)
- 2001 (106)
- 2000 (108)
- 1999 (109)
- 1998 (99)
- 1997 (99)
- 1996 (81)
- 1995 (78)
- 1994 (86)
- 1993 (59)
- 1992 (54)
- 1991 (29)
- 1990 (39)
- 1989 (45)
- 1988 (57)
- 1987 (32)
- 1986 (19)
- 1985 (34)
- 1984 (22)
- 1983 (20)
- 1982 (29)
- 1981 (20)
- 1980 (36)
- 1979 (24)
- 1978 (34)
- 1977 (14)
- 1976 (13)
- 1975 (12)
- 1974 (3)
- 1973 (2)
- 1972 (2)
- 1971 (1)
- 1968 (1)
Document Type
- Article (3226)
- Conference Proceeding (1146)
- Part of a Book (184)
- Book (144)
- Doctoral Thesis (30)
- Patent (25)
- Other (9)
- Report (9)
- Working Paper (6)
- Lecture (5)
- Poster (4)
- Preprint (4)
- Talk (4)
- Master's Thesis (2)
- Bachelor Thesis (1)
- Contribution to a Periodical (1)
- Habilitation (1)
Language
- English (4801) (remove)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (12)
- Einspielen <Werkstoff> (10)
- CAD (8)
- civil engineering (8)
- Bauingenieurwesen (7)
- Blitzschutz (6)
- FEM (6)
- Gamification (6)
- Limit analysis (6)
- Shakedown analysis (6)
- avalanche (6)
- shakedown analysis (6)
- Clusterion (5)
- Earthquake (5)
- Enterprise Architecture (5)
- MINLP (5)
- solar sail (5)
- Air purification (4)
- Diversity Management (4)
Institute
- Fachbereich Medizintechnik und Technomathematik (1668)
- Fachbereich Elektrotechnik und Informationstechnik (693)
- IfB - Institut für Bioengineering (620)
- Fachbereich Energietechnik (579)
- INB - Institut für Nano- und Biotechnologien (555)
- Fachbereich Chemie und Biotechnologie (534)
- Fachbereich Luft- und Raumfahrttechnik (477)
- Fachbereich Maschinenbau und Mechatronik (278)
- Fachbereich Wirtschaftswissenschaften (207)
- Solar-Institut Jülich (164)
- Fachbereich Bauingenieurwesen (153)
- ECSM European Center for Sustainable Mobility (79)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (67)
- Nowum-Energy (28)
- Fachbereich Gestaltung (25)
- Institut fuer Angewandte Polymerchemie (23)
- Sonstiges (21)
- Fachbereich Architektur (20)
- Freshman Institute (18)
- Kommission für Forschung und Entwicklung (18)
Microfabrication, characterization and analytical application of a new thin-film silver microsensor
(2009)
Two types of microvalves based on temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm) and pH-responsive poly(sodium acrylate) (PSA) hydrogel films have been developed and tested. The PNIPAAm and PSA hydrogel films were prepared by means of in situ photopolymerization directly inside the fluidic channel of a microfluidic chip fabricated by combining Si and SU-8 technologies. The swelling/shrinking properties and height changes of the PNIPAAm and PSA films inside the fluidic channel were studied at temperatures of deionized water from 14 to 36 °C and different pH values (pH 3–12) of Titrisol buffer, respectively. Additionally, in separate experiments, the lower critical solution temperature (LCST) of the PNIPAAm hydrogel was investigated by means of a differential scanning calorimetry (DSC) and a surface plasmon resonance (SPR) method. Mass-flow measurements have shown the feasibility of the prepared hydrogel films to work as an on-chip integrated temperature- or pH-responsive microvalve capable to switch the flow channel on/off.
It is well known that the degradation environment can strongly influence the biodegradability and kinetics of biodegradation processes of polymers. Therefore, besides the monitoring of the degradation process, it is also necessary to control the medium in which the degradation takes place. In this work, a micromachined multi-parameter sensor chip for the control of the polymer-degradation medium has been developed. The chip combines a capacitive field-effect pH sensor, a four-electrode electrolyte-conductivity sensor and a thin-film Pt-temperature sensor. The results of characterization of individual sensors are presented. In addition, the multi-parameter sensor chip together with an impedimetric polymer-degradation sensor was simultaneously characterized in degradation solutions with different pH and electrolyte conductivity. The obtained results demonstrate the feasibility of the multi-parameter sensor chip for the control of the polymer-degradation medium.
Purpose: Image analysis by the retinal vessel analyzer (RVA) observes retinal vessels in their dynamic state online noninvasively along a chosen vessel segment. It has been found that high-frequency diameter changes in the retinal artery blood column along the vessel increase significantly in anamnestically healthy volunteers with increasing age and in patients with glaucoma during vascular dilation. This study was undertaken to investigate whether longitudinal sections of the retinal artery blood column are altered in systemic hypertension.
Methods: Retinal arteries of 15 untreated patients with essential arterial hypertension (age, 50.9 ± 11.9 years) and of 15 age-matched anamnestically healthy volunteers were examined by RVA. After baseline assessment, a monochromatic luminance flicker (530–600 nm; 12.5 Hz; 20 s) was applied to evoke retinal vasodilation. Differences in amplitude and frequency of spatial artery blood column diameter change along segments (longitudinal arterial profiles) of 1 mm in length were measured and analyzed using Fourier transformation.
Results: In the control group, average reduced power spectra (ARPS) of longitudinal arterial profiles did not differ when arteries changed from constriction to dilation. In the systemic hypertension group, ARPS during constriction, baseline, and restoration were identical and differed from ARPS during dilation (P < 0.05). Longitudinal arterial profiles in both groups showed significant dissimilitude at baseline and restoration (P < 0.05).
Conclusions: The retinal artery blood column demonstrates microstructural alterations in systemic hypertension and is less irregular along the vessel axis during vessel dilation. These microstructural changes may be an indication of alterations in vessel wall rigidity, vascular endothelial function, and smooth muscle cells in this disease, leading to impaired perfusion and regulation.
A new and simple method for nanostructuring using conventional photolithography and layer expansion or pattern-size reduction technique is presented, which can further be applied for the fabrication of different nanostructures and nano-devices. The method is based on the conversion of a photolithographically patterned metal layer to a metal-oxide mask with improved pattern-size resolution using thermal oxidation. With this technique, the pattern size can be scaled down to several nanometer dimensions. The proposed method is experimentally demonstrated by preparing nanostructures with different configurations and layouts, like circles, rectangles, trapezoids, “fluidic-channel”-, “cantilever”- and meander-type structures.