Refine
Year of publication
- 2011 (82) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (82) (remove)
Document Type
- Article (69)
- Conference Proceeding (6)
- Report (3)
- Book (2)
- Doctoral Thesis (2)
Keywords
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- plant scanner (2)
- Anastomose (1)
- Anastomosis (1)
- Arthosetherapie (1)
- Biomechanics (1)
- Biomechanik (1)
- Bioreaktor (1)
- Blutzellenlagerung (1)
- Dattel (1)
- Eisschicht (1)
- Finite element method (1)
- Finite-Elemente-Methode (1)
- Gonarthrose (1)
- Harnleiter (1)
- Hemoglobin structure (1)
- Hämoglobin (1)
- Hämoglobinstruktur (1)
- Kniegelenkarthrose (1)
- MBST (1)
- Organkultur (1)
- Pflanzenstress (1)
- Red blood cell storage (1)
- Sonde (1)
- Tissue Engineering (1)
- arthrosis therapy (1)
- date palm tree (1)
- gonarthrosis (1)
- plant stress (1)
- subsurface ice research (1)
- subsurface probe (1)
Beim Ausbau nachhaltiger, regenerativer Energieversorgung hat die Umwandlung von organischer Biomasse in Biogas ein großes Potential. Der zugrundeliegende, komplexe biologische Prozess wird noch immer unzureichend verstanden und bedarf systematischer Untersuchungen der Prozessparameter, um einen hohen Ertrag bei guter Gasqualität zu ermöglichen. Die Fragestellungen zur Entschlüsselung des Prozesses sind sowohl verfahrenstechnischer als auch mikrobiologischer Natur. Aus mikrobiologischer Sicht ist die Kenntnis der tatsächlich beteiligten prozesstragenden Mikroorganismen von erheblicher Bedeutung, aus verfahrenstechnischer Sicht die Kenntnis der physikalischen und chemischen Faktoren, welche die mikrobiologischen Prozesse und kontrollieren. Im Zusammenspiel aller dieser Parameter wird die Biogasbildung befördert oder behindert, bis zum Abbruch des Prozesses.
Eine mögliche Kontrollmethode ist die Messung der metabolischen Aktivität prozesstragender Organismen.
Diese soll, beruhend auf fundierten Prozessdaten, gewonnen durch eine Parallelanlage, mit einem lichtadressierbaren potentiometrischen Sensor-System (LAPS) realisiert werden. Dieser Sensor ist in der Lage, pH-Wert-änderungen zu detektieren, die durch den Stoffwechsel der auf dem Chip immobilisierten Organismen hervorgerufen werden, um eine Online-Überwachung von Biogasanlagen zu ermöglichen.
Summary: This paper presents a methodology to study and understand the mechanics of stapled anastomotic behaviors by combining empirical experimentation and finite element analysis. Performance of stapled anastomosis is studied in terms of leakage and numerical results which are compared to in vitro experiments performed on fresh porcine tissue. Results suggest that leaks occur between the tissue and staple legs penetrating through the tissue.
A light-addressable potentiometric sensor (LAPS) can measure the concentration of one or several analytes at the sensor surface simultaneously in a spatially resolved manner. A modulated light pointer stimulates the semiconductor structure at the area of interest and a responding photocurrent can be read out. By simultaneous stimulation of several areas with light pointers of different modulation frequencies, the read out can be performed at the same time. With the new proposed controller electronic based on a field-programmable gate array (FPGA), it is possible to control the modulation frequencies, phase shifts, and light brightness of multiple light pointers independently and simultaneously. Thus, it is possible to investigate the frequency response of the sensor, and to examine the analyte concentration by the determination of the surface potential with the help of current/voltage curves and phase/voltage curves. Additionally, the ability to individually change the light intensities of each light pointer is used to perform signal correction.
HisT/PLIER : A Two-Fold Provenance Approach for Grid-Enabled Scientific Workflows Using WS-VLAM
(2011)
The purpose of this study was to investigate whether sprint performance is related to lower leg musculoskeletal geometry within a homogeneous group of highly trained 100-m sprinters. Using a cluster analysis, eighteen male sprinters were divided into two groups based on their personal best (fast: N = 11, 10.30 ± 0.07 s; slow: N = 7, 10.70 ± 0.08 s). Calf muscular fascicle arrangement and Achilles tendon moment arms (calculated by the gradient of tendon excursion versus ankle joint angle) were analyzed for each athlete using ultrasonography. Achilles tendon moment arm, foot and ankle skeletal geometry, fascicle arrangement as well as the ratio of fascicle length to Achilles tendon moment arm showed no significant (p > 0.05) correlation with sprint performance, nor were there any differences in the analyzed musculoskeletal parameters between the fast and slow sprinter group. Our findings provide evidence that differences in sprint ability in world-class athletes are not a result of differences in the geometrical design of the lower leg even when considering both skeletal and muscular components.