Refine
Year of publication
- 2014 (280) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (58)
- Fachbereich Chemie und Biotechnologie (43)
- Fachbereich Elektrotechnik und Informationstechnik (41)
- Fachbereich Wirtschaftswissenschaften (41)
- Fachbereich Energietechnik (40)
- INB - Institut für Nano- und Biotechnologien (35)
- IfB - Institut für Bioengineering (19)
- Fachbereich Maschinenbau und Mechatronik (15)
- Fachbereich Luft- und Raumfahrttechnik (13)
- Fachbereich Bauingenieurwesen (11)
Has Fulltext
- no (280) (remove)
Document Type
- Article (138)
- Conference Proceeding (55)
- Part of a Book (30)
- Book (21)
- Conference: Meeting Abstract (15)
- Report (8)
- Other (6)
- Patent (2)
- Conference Poster (1)
- Doctoral Thesis (1)
Keywords
Üblicherweise werden biotechnologische Reaktionssysteme im mikrofluidischen Maßstab in vorstrukturierten Bauteilen oder mit auf Wellplatten basierenden Robotersystemen realisiert. In dem hier vorgestellten System werden chemische oder biologische Reaktionen mit magnetischen Mikroreaktoren (MR) durchgeführt, bei denen hydrophobe magnetische Mikropartikel einen wässrigen Kern umschließen. Solche MR bieten eine gute Kontrolle der Reaktionsbedingungen, eine verbesserte Sicherheit und Portabilität. Die neue Plattformtechnologie ermöglicht die zweidimensionale Bewegung der magnetischen MR auf einer planaren Ebene. Oberhalb oder unterhalb der Plattform werden Magnetfeldgradienten zum Manipulieren und Bewegen eines oder mehrerer magnetischer MR erzeugt. Die optimal auf die MR wirkenden magnetischen Kräfte werden experimentell ermittelt und simuliert. Die Aktivierung der Magnetfelder wird automatisiert durch elektrische Spulen mit Eisenkern bzw. Neodymmagnet gesteuert. Angewendet wurde das System beim reversiblen Öffnen von MR, um z. B. Reaktionspartner in den wässrigen Kern zu injizieren oder Proben zu entnehmen. Ferner wurde Lac-case A und b-Glucosidase auf einer Quarzglasoberfläche immobilisiert und mit einem MR zum Reagieren gebracht. Weiterhin wurden MR fusioniert und so ein wässriger Kern bestehend aus Laccase mit einem aus dem entsprechenden Substrat Syringaldazin vereint.
Einleitung vor § 1297
(2014)
Die Informationsbroschüre „Elektromobilität in einer vernetzten Welt“ richtet sich an IT-Dienstleister. In dieser Broschüre werden mögliche Potenziale im Bereich der Elektromobilität aufgezeigt. Die Mobilität der Zukunft ist eine interdisziplinäre Angelegenheit und kein reines Automotive-Thema mehr. Beispiele wie Mobilitätsmanagement, eCommerce und Individualisierung sind im Mobilitätsbereich für die IT-Branche relevant.
Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome.
Engineering of functional interfaces / Patrick Wagner ; Theodor Doll ; Michael J. Schöning (eds.)
(2014)
The chemical imaging sensor, which is based on the principle of the light-addressable potentiometric sensor (LAPS), is a powerful tool to visualize the spatial distribution of chemical species on the sensor surface. The spatial resolution of this sensor depends on the diffusion of photocarriers excited by a modulated light. In this study, a novel hybrid fiber-optic illumination was developed to enhance the spatial resolution. It consists of a modulated light probe to generate a photocurrent signal and a ring of constant light, which suppresses the lateral diffusion of minority carriers excited by the modulated light. It is demonstrated that the spatial resolution was improved from 92 μm to 68 μm.
The development of a cost-effective hydrolysis for crude cellulose is an essential part of biorefinery developments. To establish such high solid hydrolysis, a new solid state reactor with static mixing is used. However, concentrations >10% (w/w) cause a rate and yield reduction of enzymatic hydrolysis. By optimizing the synergetic activity of cellulolytic enzymes at solid concentrations of 9%, 17% and 23% (w/w) of crude Organosolv cellulose, glucose concentrations of 57, 113 and 152 g L⁻¹ are reached. However, the glucose yield decreases from 0.81 to 0.72gg⁻¹ at 17% (w/w). Optimal conditions for hydrolysis scale-up under minimal enzyme addition are identified. As result, at 23% (w/w) crude cellulose the glucose yield increases from 0.29 to 0.49gg⁻¹. As proof of its applicability, biobutanol, succinic and itaconic acid are produced with the crude hydrolysate. The potential of the substrate is proven e.g. by a high butanol yield of 0.33gg⁻¹.
A semiconductor field-effect device has been used for an enzymatically catalyzed degradation of biopolymers for the first time. This novel technique is capable to monitor the degradation process of multiple samples in situ and in real-time. As model system, the degradation of the biopolymer poly(D, L-lactic acid) has been monitored in the degradation medium containing the enzyme lipase from Rhizomucor miehei. The obtained results demonstrate the potential of capacitive field-effect sensors for degradation studies of biodegradable polymers.
This article describes the fabrication, characterization and application of an epidermal temporary-transfer tattoo-based potentiometric sensor, coupled with a miniaturized wearable wireless transceiver, for real-time monitoring of sodium in the human perspiration. Sodium excreted during perspiration is an excellent marker for electrolyte imbalance and provides valuable information regarding an individual's physical and mental wellbeing. The realization of the new skin-worn non-invasive tattoo-like sensing device has been realized by amalgamating several state-of-the-art thick film, laser printing, solid-state potentiometry, fluidics and wireless technologies. The resulting tattoo-based potentiometric sodium sensor displays a rapid near-Nernstian response with negligible carryover effects, and good resiliency against various mechanical deformations experienced by the human epidermis. On-body testing of the tattoo sensor coupled to a wireless transceiver during exercise activity demonstrated its ability to continuously monitor sweat sodium dynamics. The real-time sweat sodium concentration was transmitted wirelessly via a body-worn transceiver from the sodium tattoo sensor to a notebook while the subjects perspired on a stationary cycle. The favorable analytical performance along with the wearable nature of the wireless transceiver makes the new epidermal potentiometric sensing system attractive for continuous monitoring the sodium dynamics in human perspiration during diverse activities relevant to the healthcare, fitness, military, healthcare and skin-care domains.
Die Erdbeben in Albstadt 1978 (Magnitude 5,7), Roermond 1992 (Magnitude 5,9) oder in Waldkirch 2004 (Magnitude 5,1) haben verdeutlicht, dass die erdbebensichere Auslegung von Mauerwerksbauten auch in Deutschland von großer Bedeutung ist. Bereits im Jahr 1981 wurde die DIN 4149 (1981) “Bauten in deutschen Erdbebengebieten – Lastannahmen, Bemessung und Ausführung üblicher Hochbauten“ eingeführt, in der aber für Mauerwerksbauten nur wenige Anforderungen gestellt wurden. Diese Norm wurde durch den NABau-Arbeitsausschuss “Erdbeben; Sonderfragen“ des Deutschen Instituts für Normung e.V. (DIN) auf Grundlage des Eurocode 8 (2004) vollständig überarbeitet und durch die DIN 4149 (2005) abgelöst, die umfangreiche Regelungen für die seismische Auslegung von Mauerwerksbauten enthält. Mittlerweile liegen die DIN EN 1998-1 (2010) und der Nationale Anhang DIN EN 1998-1/NA (2011) vor, die nach Einarbeitung der Ergebnisse der durchgeführten Anwendungserprobung bauaufsichtlich eingeführt und die DIN 4149 (2005) ersetzen werden. Der folgende Beitrag gibt einen Überblick über die seismische Berechnung und Bemessung von Mauerwerksbauten nach dem europäischen Regelwerk und illustriert deren Anwendung an einem baupraktischen Beispiel.