Refine
Year of publication
Document Type
- Article (454)
- Conference Proceeding (23)
- Part of a Book (18)
- Patent (17)
- Book (9)
- Preprint (1)
Language
- English (522) (remove)
Has Fulltext
- no (522) (remove)
Keywords
- Heparin (3)
- Chemometrics (2)
- IR spectroscopy (2)
- NMR spectroscopy (2)
- Principal component analysis (2)
- Standardization (2)
- (R)- or (S)- gamma-valerolactone (1)
- 4-hydroxy valeric acid (1)
- Alginate beads (1)
- Analytics (1)
- Authenticity (1)
- Bioeconomy (1)
- Bioethanol (1)
- Biomass (1)
- Biorefinery (1)
- Biorefinery definitions (1)
- Bladder (1)
- Bragg peak (1)
- CRISPR/Cas9 (1)
- Chimeric liver-humanized mice (1)
- Chiralidon-R (1)
- Chiralidon-S (1)
- Crude heparin (1)
- Cyclotron production (1)
- Decentral (1)
- Dehydrogenase (1)
- Detergent protease (1)
- Deuterated solvents (1)
- Deuterium NMR (1)
- Diaphorase (1)
- Drug distribution (1)
- Drug metabolism (1)
- Enzymatic biosensor (1)
- Extracellular enzymes (1)
- Ga-68 (1)
- Growth modelling (1)
- Hypersecretion (1)
- IR (1)
- Inorganic ions (1)
- Introduction (1)
- Ions (1)
- Knockout mice (1)
- Levulinic acid (1)
- Lignocellulose feedstook (1)
- Linear discriminant analysis (1)
- Manufacturer (1)
- Marker-free mutagenesis (1)
- Mechanical (1)
- Mechanical simulation (1)
- Medical radionuclide production (1)
- Metal contaminants (1)
- Microfluidic solvent extraction (1)
- Minor chemistry (1)
- Molecular modelling (1)
- Molecular weight determination (1)
- NMR (1)
- On-site (1)
- P2G (1)
- PLS-regression (1)
- Physical chemistry (1)
- Physical chemistry basics (1)
- Physical chemistry starters (1)
- Pre-treatment (1)
- Process schemes (1)
- Quality control (1)
- Quantum chemistry (1)
- Reconstruction (1)
- Renewable resources (1)
- Simultaneous determination (1)
- Soft independent modeling of class analogy (1)
- Stenotrophomonas maltophilia (1)
- Thermodynamics as minor (1)
- Toxicology (1)
- USP (1)
- Uracil-phosphoribosyltransferase (1)
- Ureter (1)
- actuator-sensor system (1)
- aspergillus (1)
- bacterial cellulose (1)
- bi-enzyme biosensor (1)
- bioavailability (1)
- biodegradable polymers (1)
- biological dosimeter (1)
- biomethane (1)
- borehole disposal (1)
- bubble column (1)
- capacitive field-effect sensor (1)
- coculture (1)
- deficit irrigation (1)
- disposal facility (1)
- drug metabolising enzymes (1)
- drug–drug interactions (1)
- elastomers (1)
- enzyme kinetics (1)
- enzyme-logic gate (1)
- exopolysaccharides (1)
- filamentous fungi (1)
- genome engineering (1)
- geological disposal (1)
- glycine (1)
- human metabolites (1)
- hydrogel (1)
- hydrogels (1)
- light-addressable electrode (1)
- light-addressable potentiometric sensor (1)
- mechanical properties (1)
- methanation (1)
- microfluidics (1)
- micronutrients (1)
- neutrons (1)
- nuclear waste (1)
- onion (1)
- optical fibers (1)
- penicillinase (1)
- plug flow reactor (1)
- polyaspartic acid (1)
- prebiotic (1)
- proton therapy (1)
- protons (1)
- pullulan (1)
- qNMR (1)
- relative dosimetry (1)
- retention time (1)
- rubber (1)
- superabsorbent polymers (1)
- supramolecular structures (1)
- swelling properties (1)
- theory and modeling (1)
- tobacco mosaic virus (TMV) (1)
- transporters (1)
- urease (1)
- water economy (1)
- yield (1)
Institute
- Fachbereich Chemie und Biotechnologie (522) (remove)
Slot die coating is applied to deposit thin and homogenous films in roll-to-roll and sheet-to-sheet applications. The critical step in operation is to choose suitable process parameters within the process window. In this work, we investigate an upper limit for stripe coatings. This maximum film thickness is characterized by stripe merging which needs to be avoided in a stable process. It is shown that the upper limit reduces the process window for stripe coatings to a major extent. As a result, stripe coatings at large coating gaps and low viscosities are only possible for relatively thick films. Explaining the upper limit, a theory of balancing the side pressure in the gap region in the cross-web direction has been developed.
Size unlimited markerless deletions by a transconjugative plasmid-system in Bacillus licheniformis
(2013)
We present an electromechanically coupled Finite Element model for cardiac tissue. It bases on the mechanical model for cardiac tissue of Hunter et al. that we couple to the McAllister-Noble-Tsien electrophysiological model of purkinje fibre cells. The corresponding system of ordinary differential equations is implemented on the level of the constitutive equations in a geometrically and physically nonlinear version of the so-called edge-based smoothed FEM for plates. Mechanical material parameters are determined from our own pressure-deflection experimental setup. The main purpose of the model is to further examine the experimental results not only on mechanical but also on electrophysiological level down to ion channel gates. Moreover, we present first drug treatment simulations and validate the model with respect to the experiments.
In this study, a recently proposed NMR standardization approach by 2H integral of deuterated solvent for quantitative multicomponent analysis of complex mixtures is presented. As a proof of principle, the existing NMR routine for the analysis of Aloe vera products was modified. Instead of using absolute integrals of targeted compounds and internal standard (nicotinamide) from 1H-NMR spectra, quantification was performed based on the ratio of a particular 1H-NMR compound integral and 2H-NMR signal of deuterated solvent D2O. Validation characteristics (linearity, repeatability, accuracy) were evaluated and the results showed that the method has the same precision as internal standardization in case of multicomponent screening. Moreover, a dehydration process by freeze drying is not necessary for the new routine. Now, our NMR profiling of A. vera products needs only limited sample preparation and data processing. The new standardization methodology provides an appealing alternative for multicomponent NMR screening. In general, this novel approach, using standardization by 2H integral, benefits from reduced sample preparation steps and uncertainties, and is recommended in different application areas (purity determination, forensics, pharmaceutical analysis, etc.).