Article
Refine
Year of publication
- 2024 (1)
- 2023 (5)
- 2022 (8)
- 2021 (3)
- 2020 (7)
- 2019 (9)
- 2018 (4)
- 2017 (6)
- 2016 (3)
- 2015 (5)
- 2014 (3)
- 2013 (6)
- 2012 (1)
- 2011 (8)
- 2010 (10)
- 2009 (5)
- 2008 (11)
- 2007 (4)
- 2006 (7)
- 2005 (7)
- 2004 (16)
- 2003 (6)
- 2002 (12)
- 2001 (10)
- 2000 (13)
- 1999 (15)
- 1998 (16)
- 1997 (23)
- 1996 (22)
- 1995 (15)
- 1994 (14)
- 1993 (11)
- 1992 (8)
- 1991 (4)
- 1990 (3)
- 1989 (11)
- 1988 (9)
- 1987 (6)
- 1986 (7)
- 1985 (6)
- 1984 (4)
- 1983 (5)
- 1982 (1)
- 1981 (3)
- 1980 (3)
- 1979 (2)
- 1978 (1)
- 1977 (1)
- 1975 (1)
Institute
- Fachbereich Energietechnik (361) (remove)
Language
- English (361) (remove)
Document Type
- Article (361) (remove)
Keywords
- Earthquake (4)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Antibias (1)
- Artificial intelligence (1)
- Behaviour factor q (1)
- Biogas (1)
- Cardiovascular MRI (1)
- Circular bioeconomy (1)
- Civil engineering (1)
Control of Aharonov-Bohm oscillations in a AlGaAs/GaAs ring by asymmetric and symmetric gate biasing
(2001)
Comparison of solar hot water systems in solar settlements - decentralized or centralized systems?
(2004)
Comparison of single point and equipotential bonding for I&C systems of large-area industrial sites
(1994)
Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT’s performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)%). Conclusions: ACT’s intrinsic insensitivity to interference from electromagnetic fields renders