Refine
Year of publication
- 2013 (173) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (54)
- INB - Institut für Nano- und Biotechnologien (35)
- Fachbereich Elektrotechnik und Informationstechnik (29)
- Fachbereich Chemie und Biotechnologie (26)
- IfB - Institut für Bioengineering (24)
- Fachbereich Energietechnik (16)
- Fachbereich Luft- und Raumfahrttechnik (14)
- Fachbereich Wirtschaftswissenschaften (12)
- Fachbereich Bauingenieurwesen (9)
- Sonstiges (6)
Language
- English (173) (remove)
Document Type
- Article (97)
- Conference Proceeding (57)
- Part of a Book (7)
- Doctoral Thesis (3)
- Book (2)
- Other (2)
- Patent (2)
- Report (2)
- Conference: Meeting Abstract (1)
Keywords
- industrial research (2)
- metal structure (2)
- steel (2)
- Bacillus atrophaeus (1)
- Business Models (1)
- Epithel (1)
- Fibroblast (1)
- IT Products (1)
- Product Management (1)
- Strategic Business Planning (1)
Purpose
To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T.
Methods
The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study.
Results
Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly.
Conclusion
The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T.
Modeling contribution to risk assessment of thermal production power for geothermal reservoirs
(2013)
Living cells are complex biological systems transforming metabolites taken up from the surrounding medium. Monitoring the responses of such cells to certain substrate concentrations is a challenging task and offers possibilities to gain insight into the vitality of a community influenced by the growth environment. Cell-based sensors represent a promising platform for monitoring the metabolic activity and thus, the “welfare” of relevant organisms. In the present study, metabolic responses of the model bacterium Escherichia coli in suspension, layered onto a capacitive field-effect structure, were examined to pulses of glucose in the concentration range between 0.05 and 2 mM. It was found that acidification of the surrounding medium takes place immediately after glucose addition and follows Michaelis–Menten kinetic behavior as a function of the glucose concentration. In future, the presented setup can, therefore, be used to study substrate specificities on the enzymatic level and may as well be used to perform investigations of more complex metabolic responses. Conclusions and perspectives highlighting this system are discussed.
Mass transfer correlation for evaporation–condensation thermal process in the range of 70 °C–95 °C
(2013)
Introduction of RePriCo’13
(2013)