Article
Refine
Year of publication
- 2011 (182) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (69)
- INB - Institut für Nano- und Biotechnologien (36)
- Fachbereich Elektrotechnik und Informationstechnik (25)
- Fachbereich Chemie und Biotechnologie (22)
- IfB - Institut für Bioengineering (22)
- Fachbereich Wirtschaftswissenschaften (19)
- Fachbereich Energietechnik (13)
- Fachbereich Bauingenieurwesen (12)
- Fachbereich Maschinenbau und Mechatronik (10)
- Fachbereich Luft- und Raumfahrttechnik (9)
Document Type
- Article (182) (remove)
Keywords
- Arthosetherapie (1)
- Bioreaktor (1)
- Blutzellenlagerung (1)
- Gonarthrose (1)
- Harnleiter (1)
- Hemoglobin structure (1)
- High field MRI (1)
- Hämoglobin (1)
- Hämoglobinstruktur (1)
- Kniegelenkarthrose (1)
- MBST (1)
- MR safety (1)
- MRI (1)
- Magneto alert sensor (1)
- Organkultur (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Pflanzenstress (1)
- Pornographie (1)
- Red blood cell storage (1)
- Tissue Engineering (1)
- Uktrahigh field MRI (1)
- Zuschauer (1)
- arthrosis therapy (1)
- avalanche (1)
- gonarthrosis (1)
- plant scanner (1)
- plant stress (1)
- snow (1)
Purpose
To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T.
Materials and Methods
A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3.
Results
Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach.
Conclusion
A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.