Conference Proceeding
Refine
Year of publication
Institute
- Fachbereich Energietechnik (177) (remove)
Language
- English (177) (remove)
Document Type
- Conference Proceeding (177) (remove)
Keywords
- Blitzschutz (6)
- Energy storage (4)
- Power plants (4)
- Associated liquids (3)
- Concentrated solar power (3)
- Elektromagnetischer Schutzschild (3)
- Hybrid energy system (3)
- Lightning (3)
- Out-of-plane load (3)
- earthquakes (3)
- Adjacent buildings (2)
- Direkter Blitzschlag (2)
- Diversity (2)
- Diversity Management (2)
- Electricity generation (2)
- Erneuerbare Energien (2)
- Historical centres (2)
- Hybridsystem (2)
- INODIS (2)
- Induzierte Spannungen (2)
- Innovation Management (2)
- Lightning protection (2)
- Lightning protection system (2)
- Magnetische Felder (2)
- Renewable energy (2)
- Risikoabwägung (2)
- Seismic loading (2)
- Shake table test (2)
- Solar thermal technologies (2)
- Stone masonry (2)
- cyber physical production system (2)
- digital shadow (2)
- electromagnetic shielding (2)
- engineering education (2)
- industrial facilities (2)
- installations (2)
- piping (2)
- reinforced concrete (2)
- seismic design (2)
- seismic loading (2)
- Acceptance (1)
- Blind prediction competition (1)
- Blitz (1)
- Blitzrisiko (1)
- Blitzschlag (1)
- Bloom Taxonomy (1)
- COMSOL Multiphysics (1)
- Camera system (1)
- Capacity Curve (1)
- Ceramics (1)
- Change Management (1)
- Cloud passages (1)
- Control optimization (1)
- Corporate Culture (1)
- DNI forecast (1)
- DNI forecasting (1)
- Decision theory (1)
- Design Thinking (1)
- Digitalization (1)
- Direct lightning strike (1)
- Direct normal irradiance forecast (1)
- District data model (1)
- District energy planning platform (1)
- EN 1998-4 (1)
- ESHM20, industrial facilities (1)
- Earthquake (1)
- Earthquake Engineering (1)
- Electrochemistry (1)
- Elektromagnetische Kopplung (1)
- Energietechnik (1)
- Energy (1)
- Energy Systems (1)
- Energy system (1)
- Energy system planning (1)
- Engineering (1)
- Engineering Education (1)
- Ethics (1)
- Future Skills (1)
- Future skills (1)
- Gasturbine (1)
- Gender (1)
- Global change (1)
- Heliostat Field Calibration (1)
- Heliostats (1)
- Higher Education (1)
- Human factors (1)
- Human-robot collaboration (1)
- In- plane damage (1)
- In-plane (1)
- In-plane load (1)
- Industrial facilities (1)
- Industrieanlagen (1)
- Innovation (1)
- Interaction (1)
- Interculturality (1)
- Interdisciplinarity (1)
- Isolation (1)
- Kalkulation (1)
- Kernenergie (1)
- Key competences (1)
- Kraftwerke (1)
- Leadership (1)
- Lightning Protection (1)
- Lightning Risk (1)
- LiveLink for MATLAB (1)
- Masonry infill (1)
- Masonry structures (1)
- Maßstabsgetreues Modell (1)
- Measuring instruments (1)
- Micro turbine (1)
- Mikrogasturbine (1)
- Mixed integer linear programming (MILP) (1)
- Molten salt receiver (1)
- Molten salt receiver system, (1)
- Neo-Deterministic (1)
- Nowcasting (1)
- Nuclear Applications (1)
- Optimization module (1)
- Out-of-plane (1)
- Out-of-plane failure (1)
- Out-of-plane strength (1)
- PTC (1)
- Parabolic trough collector (1)
- Photovoltaics (1)
- Photovoltaikanlage (1)
- Process prediction (1)
- Pyrometrie (1)
- Quadrocopter (1)
- RC frames (1)
- Renewable energy integration (1)
- Risiko (1)
- Risk (1)
- Risk Assessment (1)
- Risk Management (1)
- Seismic (1)
- Seismic Hazard (1)
- Seismic design (1)
- Social impact measurement (1)
- Solar irradiance (1)
- Stahlbeton (1)
- Stahlbetonkonstruktion (1)
- Star design (1)
- Structural health monitoring (1)
- Sustainability (1)
- Sustainable engineering education (1)
- Tanks (1)
- Temperaturmessung (1)
- Thermal Energy Storage (1)
- Time-series aggregation (1)
- Typical periods (1)
- UAV (1)
- Umwelt (1)
- Uncertainty analysis (1)
- Unmanned aerial vehicle (1)
- Unreinforced masonry walls (1)
- Vulnerability Curves (1)
- Windenergieanlage (1)
- Window opening (1)
- acoustic pyrometry (1)
- behaviour factor q (1)
- best practice (1)
- calculations (1)
- connection detail (1)
- current distribution (1)
- cyber-physical production system (1)
- digital twin (1)
- digitalization (1)
- dissemination (1)
- diversity (1)
- down-conductor (1)
- early warning and response system (1)
- earthquake (1)
- education (1)
- elastomeric bearing (1)
- electromagnetic coupling (1)
- electromagnetic shield (1)
- energy transition (1)
- environment (1)
- finite element method (1)
- flue gas components (1)
- fluid structure interaction (1)
- fragility curves (1)
- friction pendulum bearing (1)
- gender and diversity (1)
- human digital shadow (1)
- human factors (1)
- human-machine interface (1)
- hybrid system (1)
- hybrid-system (1)
- in-plane (1)
- in-plane and out-of-plane failure (1)
- induced voltage (1)
- induced voltages (1)
- innovation (1)
- integration SHM in BIM (1)
- interconnected sensor systems (1)
- internet of production (1)
- lightning flash (1)
- linear elastic analysis; (1)
- liquid storage tank (1)
- magnetic field (1)
- magnetic fields (1)
- masonry structures (1)
- metal façade (1)
- modern constructions (1)
- open educational resources (1)
- out-of-plane (1)
- overvoltages (1)
- photovoltaic system (1)
- protection measures (1)
- renewable energies (1)
- renewable energy (1)
- risk assessment (1)
- safety control (1)
- scaled model (1)
- seismic hazard (1)
- seismic isolation (1)
- seismic risk (1)
- seismic structural damage detection via SHM (1)
- seismic vulnerability (1)
- simplified approach (1)
- social responsible engineering (1)
- steam production (1)
- steel columns (1)
- storage dispatch (1)
- storage optimisation (1)
- teaching (1)
- temperature measurement (1)
- thermal storage (1)
- touch voltage (1)
- unreinforced masonry buildings (1)
- user & usage (1)
- vocal fold oscillation (1)
- wind turbine (1)
- Überspannung (1)
Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I&C-cables.
Lightning protection design of a renewable energy hybrid-system without power mains connection
(2001)
In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system.
The paper deals with the development of the probabilistic approach to the assessment of risk due to lightning. Sources of damage, types of damage and types of loss are defined and, accordingly, the procedure for risk analysis and the way of assessment of different risk components is proposed. The way to evaluate the influence of different protection measures (lightning protection system; shielding of structure, cables and equipment; routing of internal wiring; surge protective device) in reducing such probabilities is considered. The paper has been prepared within the framework of the activity of IEC TC81-WG9/CLC TC81-WG4 directed to prepare the draft IEC 62305-2 Risk Management, in cooperation with the Secretary of IEC/CLC TC81.
In the paper a lightning protection design concept for renewable energy hybrid-systems without power mains connection is described. Based on a risk analysis protection measures against direct strikes and overvoltages are shown in an overview. The design concept is realized exemplarily for the hybrid-system VATALI on the Greek island Crete. VATALI, not lightning protected at that time, was a victim of a lightning strike in the year 2000 causing destructions and damages of some mechanical and electrical components with costs of approx. 60.000 €. The hardware costs for the protection measures were about 15.000 €: about 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection.
In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between “floor” and “roof” in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived.