Refine
Year of publication
- 2012 (41) (remove)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (41) (remove)
Document Type
- Article (16)
- Conference Proceeding (13)
- Conference: Meeting Abstract (5)
- Book (2)
- Part of a Book (2)
- Patent (2)
- Doctoral Thesis (1)
Keywords
- Gleichspannungswandler (1)
- IP-based networks (1)
- IndraMotion (1)
- MATLAB , MLPI , Motion control , Open Core , industrial drives , rapid control prototypin , sercos automation bus (1)
- Motion-Logic System (1)
- NGN (1)
- SPS (1)
- Speicherprogrammierte Steuerung (1)
- Wärmeübertragung (1)
- next generation network (1)
Mit freundlicher Genehmigung der Autoren und des Oldenbourg Industrieverlags https://www.oldenbourg-industrieverlag.de/de/9783835633223-33223 erschienen als Beitrag im Tagungsband zur AALE-Tagung 2012. 9. Fachkonferenz 4.-5. Mai 2012, Aachen, Fachhochschule. ISBN 9783835633223 S 2-1 S. 37-46 Original-Abstract der Autoren: "Dieser Artikel beschreibt eine universelle Programmierschnittstelle zur Entwicklung von Motion-Logic Applikationen für industrielle Motion-Controller. Sie ermöglicht die Entwicklung von Software mit modernen Hochsprachen, wie C/C++. Visual Basic, C#, Java, Objective-Cund visuellen Programmiersprachen, wie LabVIEW in Koexistenz mit klassischen Programmiersprachen für speicherprogrammierbare Steuerungen nach IEC 61131-3. Daraus ergeben sich neue Möglichkeiten industrielle Antriebs- und Steuerungssysteme mit ihrem IT-Umfeld zu verbinden."
Mit freundlicher Genehmigung der Autoren und des Oldenbourg Industrieverlags https://www.oldenbourg-industrieverlag.de/de/9783835633223-33223 erschienen als Beitrag im Tagungsband zur AALE-Tagung 2012. 9. Fachkonferenz 4.-5. Mai 2012, Aachen, Fachhochschule. ISBN 9783835633223 S 6-2. S. 165-174 Zusammenfassung der Autoren: "Abschließend kann festgehalten werden, dass die gesamten durchgeführten Überlegungen von den Messergebnissen der Inbetriebnahme positiv bestätigt werden. Es wird durch diese Topologie eine maximale Systemverfügbarkeit garantiert und die Zellen werden optimal betrieben. Ein Blick in die Zukunft für dieses Projekt zeigt viele Erweiterungs- und Optimierungsaufgaben. So muss der DC/DC-Wandler für einen bidirektionalen Betrieb erweitert werden, um einen Rekuperationsbetrieb zu gewährleisten bzw. die Zellen laden zu können. Dadurch können gleichzeitig die Gleichrichterdioden im Sekundärleistungsteil durch IGBTs oder MOSFETs ersetzt werden. Die voll funktionsfähige Version des DC/DC-Wandlers könnte höchstwahrscheinlich direkt auf die Anschlusspole der Zelle montiert werden, wodurch das Gewicht gesenkt wird. Durch die verringerte Verlustleistung in den Zuleitungen könnte der Wirkungsgrad noch einmal gesteigert werden.
Energieeffizienz und Energiemanagement : ein Überblick heutiger Möglichkeiten und Notwendigkeiten
(2012)
Energieeffizienz und Energiemanagement : Ein Überblick heutiger Möglichkeiten und Notwendigkeiten
(2012)
Auswahl der Herniennetze nach der “effektiven Porosität” - warum das Gewicht weniger wichtig ist
(2012)
If we think about applications for modern Power MOSFETs using trench technology, running them in linear mode may not be top of the priority list. Yet there are multiple uses for Trench Power MOSFETs in linear mode. In fact, even turning the device on and off in switching applications is a form of linear operation. Also, these components can be run in linear mode to protect the device against voltage surges. This article will illustrate the factors that need to be considered for linear operation and show how Trench Power MOSFETs are suited to it.
This article describes the functionality of a MATLAB® library that can be used to develop motion-logic applications in MATLAB programming language for industrial drive and control systems using the well known sercos automation bus. Therewith MATLAB's functionality is extended to designing automation applications from single axis machines up to multi-kinematic robots.
Assessment of RF Safety of Transmit Coils at 7 Tesla by Experimental and Numerical Procedures (490.)
(2012)
As the potential of a next generation network (NGN) is recognised, telecommunication companies consider switching to it. Although the implementation of an NGN seems to be merely a modification of the network infrastructure, it may trigger or require changes in the whole company, because it builds upon the separation between service and transport, a flexible bundling of services to products and the streamlining of the IT infrastructure. We propose a holistic framework, structured into the layers ‘strategy’, ‘processes’ and ‘information systems’ and incorporate into each layer all concepts necessary for the implementation of an NGN, as well as the alignment of these concepts. As a first proof-of-concept for our framework we have performed a case study on the introduction of NGN in a large telecommunication company; we show that our framework captures all topics that are affected by an NGN implementation.
Die Veränderungen des Telekommunikationsmarktes haben in der Praxis zu einer Vielzahl von Transformationsprojekten geführt. Was gehört aber zu einem “Transformationsprojekt”, welche Prozesse und Systeme werden verändert? Zur Beantwortung dieser Frage haben wir 184 Berichte zu Projekten analysiert, die als "Transformationsprojekte" bezeichnet waren. Für die Analyse haben wir einen Kodierungsrahmen konzipiert und anhand dessen die Berichte mit einem hierarchischen Clustering-Verfahren in Themen gruppiert. Die Ergebnisse liefern Hinweise über die in der Praxis gesetzten Schwerpunkte und Prioritäten. Sie können
somit als Unterstützung für Unternehmen dienen, die ein Transformationsprojekt planen. Sie weisen zudem darauf hin, in welchen Bereichen eines Unternehmens Unterstützung durch wissenschaftlich erprobte Werkzeuge und Modelle nötig ist.
s the magnetic field strength and therefore the operational frequency in MRI are increased, the radiofrequency wavelength approaches the size of the human head/body, resulting in wave effects which cause signal decreases and dropouts. Especially, whole-body imaging at 7 T and higher is therefore challenging. Recently, an acquisition scheme called time-interleaved acquisition of modes has been proposed to tackle the inhomogeneity problems in high-field MRI. The basic premise is to excite two (or more) different Burn:x-wiley:07403194:media:MRM23081:tex2gif-stack-1 modes using static radiofrequency shimming in an interleaved acquisition, where the complementary radiofrequency patterns of the two modes can be exploited to improve overall signal homogeneity. In this work, the impact of time-interleaved acquisition of mode on image contrast as well as on time-averaged specific absorption rate is addressed in detail. Time-interleaved acquisition of mode is superior in Burn:x-wiley:07403194:media:MRM23081:tex2gif-stack-2 homogeneity compared with conventional radiofrequency shimming while being highly specific absorption rate efficient. Time-interleaved acquisition of modes can enable almost homogeneous high-field imaging throughout the entire field of view in PD, T2, and T2*-weighted imaging and, if a specified homogeneity criterion is met, in T1-weighted imaging as well.
31P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D 31P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a 31P endorectal coil was developed and combined with an eight-channel 1H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and Burn:x-wiley:07403194:media:MRM24175:tex2gif-stack-1 measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the 31P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel 1H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the 1H array coil was allowed. For transmitting with the 31P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D 31P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm3. The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer.
This contribution discusses the utilization of RF power in an MRI system with RF mode shimming which enables the superposition of circularly polarized modes of a transmit RF coil array driven by a Butler matrix. Since the required power for the individual modes can vary widely, mode-shimming can result in a significant underutilization of the total available RF power. A variable power combiner (VPC) is proposed to improve the power utilization: it can be realized as a reconfiguration of the MRI transmit system by the inclusion of one additional matrix network which receives the power from all transmit amplifiers at its input ports and provides any desired (combined) power distribution at its output ports by controlling the phase and amplitude of the amplifiers’ input signals. The power distribution at the output ports of the VPC is then fed into the “mode” ports of the coil array Butler matrix in order to superimpose the spatial modes at the highest achievable power utilization. The VPC configuration is compared to the standard configuration of the transmit chain of our MRI system with 8 transmit channels and 16 coils. In realistic scenarios, improved power utilization was achieved from 17% to 60% and from 14% to 55% for an elliptical phantom and a region of interest in the abdomen, respectively, and an increase of the power utilization of 1 dB for a region of interest in the upper leg. In general, it is found that the VPC allows significant improvement in power utilization when the shimming solution demands only a few modes to be energized, while the technique can yield loss in power utilization in cases with many modes required at high power level.
This thesis introduces the Integrated Emitter Turn-Off (IETO) Thyristor as a new high-power device. Known state-of-the-art research activities like the Dual GCT, the ETO thyristor and the ICT were presented and critically reviewed. A comparison with commercialized solutions identifies the pros and cons of each type of device family. Based on this analysis, the IETO structure is proposed, covering most benefits of each device class. In particular the combination of a MOS-assisted turn-off with a thyristor-based device allows a voltage-controlled MOS switching and the low on-state voltage of the thyristors. The following synthesis of an IETO device stands on a three-dimensional field of optimization spanned by electric, mechanical and thermal aspects. From an electric point of view, the lowest possible parasitic inductance and resistance within the commutation path are optimization criteria. The mechanical construction has to withstand the required contact pressure of multiple kilo Newtons. Finally, thermal borders limit the maximum average current of the device. FEM simulations covering these three aspects are performed for several design proposals. An IETO prototype is constructed and measurements on various test benches attest thermal, mechanical and electric performance. A local decoupling of the external driver stage and the presspack housing is presented by a cable connection. This separation enables a thermal and mechanical independence, which is advantageous in terms of vibrations and thermal cycles including increased reliability. The electric pulse performance of the prototype device is a factor of 3.1 above today''s solutions. In single-pulse measurements, a current up to 1600 A was successfully turned off at 115°C with an active silicon area of 823 mm². One reason for this increased turn-off capability is the extremely low-inductive construction. Additional functionality of the IETO thyristor like over-current self-protection and defined short-circuit failure state are successfully verified.
Security Awareness ist derzeit ein viel diskutiertes Thema. Es reicht nicht, einfach nur ein paar technische Systeme (z.B. Firewalls) zu installieren, um ein angemessenes Schutzniveau zu erzielen. Neben einer guten Organisation von IT Security ist es auch notwendig, den Mitarbeiter einzubinden. Der vielzitierte "Faktor Mensch" ist derjenige, der die Technik korrekt anwenden muss und der durch falsches Verhalten technische und organisatorische Schutzmaßnahmen aushebeln kann. Deshalb reicht es nicht aus, wenn sich der Mitarbeiter der Gefahren bewusst ("aware") ist, er muss auch dementsprechend "sicher" handeln.