Refine
Year of publication
Document Type
- Conference Proceeding (77)
- Article (44)
- Lecture (2)
Language
- English (123) (remove)
Has Fulltext
- yes (123) (remove)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (12)
- Einspielen <Werkstoff> (10)
- CAD (8)
- civil engineering (8)
- Bauingenieurwesen (7)
- FEM (6)
- Clusterion (5)
- shakedown analysis (5)
- Air purification (4)
- Hämoglobin (4)
- Limit analysis (4)
- Luftreiniger (4)
- Plasmacluster ion technology (4)
- Raumluft (4)
- Shakedown analysis (4)
- Einspielanalyse (3)
- Kohlenstofffaser (3)
- Lipopolysaccharide (3)
- Shakedown (3)
- Sonde (3)
- Technische Mechanik (3)
- Traglastanalyse (3)
- limit analysis (3)
- lipopolysaccharides (3)
- shakedown (3)
- Analytischer Zulaessigkeitsnachweis (2)
- Bruchmechanik (2)
- Capacitive field-effect sensor (2)
- Einspiel-Analyse (2)
- Eisschicht (2)
- Erythrozyt (2)
- Fibroblast (2)
- Label-free detection (2)
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- Stickstoffmonoxid (2)
- Traglast (2)
- biosensor (2)
- biosensors (2)
- capacitive field-effect sensors (2)
- celldrum technology (2)
- limit load (2)
- nanostructured carbonized plant parts (2)
- nanostrukturierte carbonisierte Pflanzenteile (2)
- nitric oxide gas (2)
- plant scanner (2)
- ratchetting (2)
- 3-nitrofluoranthene (1)
- Adsorption (1)
- Alternating plasticity (1)
- Analysis (1)
- Anastomose (1)
- Anastomosis (1)
- Architectural design (1)
- Autofluoreszenzverfahren (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- BTEX compounds (1)
- Bacterial cellulose (1)
- Bakterien (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bicharakteristikenverfahren (1)
- Bio-Sensors (1)
- Bioabsorbable (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Biophoton (1)
- Bioreaktor (1)
- Biosensorik (1)
- Blitzschutz (1)
- Blutzellenlagerung (1)
- Bone quality and biomechanics (1)
- CAD ; (1)
- CO (1)
- Carbon sources (1)
- Cellulose nanostructure (1)
- Cement infiltration (1)
- Conducing polymer (1)
- Convex optimization (1)
- Cost-effectiveness (1)
- Culture media (1)
- Dattel (1)
- Deformation (1)
- Dekontamination (1)
- Design-by-analysis (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- Druckgeräte (1)
- ECT (1)
- ELISA (1)
- EPN (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Elastodynamik (1)
- Elastostatics (1)
- Elektrodynamik (1)
- Endothelzelle (1)
- Enterprise information systems (1)
- Environmental impact (1)
- Enzyme-linked immunosorbent assay (1)
- Epithel (1)
- Exact Ilyushin yield surface (1)
- Experiment (1)
- Fault approximation (1)
- Fault detection (1)
- Fehlerstellen (1)
- Festkörper (1)
- Finite element method (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fließgrenze (1)
- Fluorescence (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Geriatric (1)
- German (1)
- Global and local collapse (1)
- Gold nanoparticles (1)
- Grenzwertberechnung (1)
- Gunn diode (1)
- Harnleiter (1)
- Heavy metal detection (1)
- Hemoglobin structure (1)
- High throughput experimentation (1)
- Hip fractures (1)
- Hotplate (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Hydrogen sensor (1)
- Hämoglobinstruktur (1)
- I3S 2005 (1)
- ISFET (1)
- Information extraction (1)
- International Symposium on Sensor Science (1)
- Inverse scattering problem (1)
- Kinematics (1)
- Kinetics (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Körpertemperatur (1)
- LED chip (1)
- Level sensor (1)
- Lichtstreuungsbasierte Instrumente (1)
- MCDA (1)
- MEMS (1)
- Main sensitivity (1)
- Materialermüdung (1)
- Mechanics (1)
- Mechanische Beanspruchung (1)
- Medusomyces gisevi (1)
- Microreactors (1)
- Model-driven software engineering (1)
- Multi-dimensional wave propagation (1)
- Multicell (1)
- Multiplexing (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanoparticles (1)
- Nanopartikel (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Natriumhypochlorit (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Organkultur (1)
- Organophosphorus (1)
- Ostazine Orange (1)
- Osteoporose (1)
- Osteoporosis (1)
- PFM (1)
- Permeability (1)
- Permeabilität (1)
- Peroxidase (1)
- Pflanzenstress (1)
- Phenylalanine determination (1)
- Plant virus (1)
- Plastizität (1)
- Polylactide acid (1)
- Potentiometry (1)
- Pressure loaded crack-face (1)
- Prevention (1)
- Progressive plastic deformation (1)
- Prophylaxis (1)
- Proteine (1)
- Pseudomonas putida (1)
- Quartz crystal nanobalance (QCN) (1)
- Quartz micro balances (1)
- Random variable (1)
- Ratcheting (1)
- Ratchetting (1)
- Reaction-diffusion (1)
- Red blood cell storage (1)
- Resistive temperature detector (1)
- Rohr (1)
- Rohrbruch (1)
- Schwammknochen (1)
- Sensitivity (1)
- Sepsis (1)
- Shakedown criterion (1)
- Silk fibroin (1)
- Skeletal muscle (1)
- Small Aral Sea (1)
- Software and systems modeling (1)
- Solid amalgam electrodes (1)
- Stahl (1)
- Statics (1)
- Strukturanalyse (1)
- Supraleiter (1)
- Temperaturabhängigkeit (1)
- Tendons (1)
- Tin oxide (1)
- Tissue Engineering (1)
- Tobacco mosaic virus (TMV) (1)
- UML (1)
- Ultrasound (1)
- Unified Modeling Language (1)
- Vertebroplastie (1)
- Vertebroplasty (1)
- Viscous flow (1)
- Viskose Strömung (1)
- Viskosität (1)
- Wafer (1)
- Wasserbrücke (1)
- Wasserstoffperoxid (1)
- Wellen (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Wundheilung (1)
- Zeta potential (1)
- Zug-Druck Belastung (1)
- acetoin (1)
- acetoin reductase (1)
- activated nanostructured carbon (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- alcoholic beverages (1)
- alternierend Verformbarkeit (1)
- ammonia gas sensors (1)
- amperometric biosensors (1)
- amperometric sensor (1)
- antimony doped tin oxide (1)
- aromatic amines (1)
- atomic layer deposition (1)
- autofluorescence-based detection system (1)
- bicharacteristics (1)
- bioburdens (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- bone density (1)
- bone structure (1)
- burst pressure (1)
- burst tests (1)
- cancellous bone (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capillary micro-droplet cell (1)
- carbon electrodes (1)
- carbonized rice husk (1)
- carcinogens (1)
- catalytic decomposition (1)
- chemical reduction method (1)
- contractile tension (1)
- cross sensitivity (1)
- cytosolic water diffusion (1)
- date palm tree (1)
- design-by-analysis (1)
- direct method (1)
- doped metal oxide (1)
- doped silicon (1)
- doping (1)
- ecological structure (1)
- elastic solids (1)
- electrical capacitance tomography (1)
- electro-migration (1)
- electronic noses dendronized polymers inverted mesa technology (1)
- encapsulation materials (1)
- enzymatic biosensor (1)
- enzymatic methods (1)
- enzyme immobilisation (1)
- epithelization (1)
- fatigue analyses (1)
- fenitrothion (1)
- fibroin (1)
- finite element analysis (1)
- flaw (1)
- fluidic (1)
- fortschreitende plastische Deformation (1)
- gas sensor (1)
- gas sensor array (1)
- glucose (1)
- graphene oxide (1)
- heater metallisation (1)
- hemoglobin (1)
- hemoglobin dynamics (1)
- high-temperature stability (1)
- human dermal fibroblasts (1)
- humidity (1)
- hydrogel (1)
- hydrogen peroxide (1)
- image sensor (1)
- imaging (1)
- impedance spectroscopy (1)
- ion-selective electrodes (1)
- kontraktile Spannung (1)
- konvexe Optimierung (1)
- lab-on-a-chip (1)
- lab-on-chip (1)
- large language models (1)
- layer expansion (1)
- layer-by-layer technique (1)
- lenslet array (1)
- light scattering analysis (1)
- lightning flash (1)
- limit and shakedown analysis (1)
- linear kinematic hardening (1)
- load limit (1)
- lower bound theorem (1)
- magnetic particles (1)
- material shakedown (1)
- matrix method (1)
- mechanical waves (1)
- metagenomics (1)
- metal oxide (1)
- microbial diversity (1)
- microreactor (1)
- microwave generation (1)
- modeling biosensor (1)
- modelling (1)
- modified electrode (1)
- multi-interface measurement (1)
- nanomaterials (1)
- naphtols (1)
- nitrogen oxides (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- organic PVC membranes (1)
- pH sensors (1)
- pH-based biosensing (1)
- pattern-size reduction (1)
- penicillin (1)
- penicillinase (1)
- phenols (1)
- photoelectrochemistry (1)
- pipes (1)
- plant stress (1)
- plasma generated ions (1)
- polyaniline (1)
- polymer composites (1)
- porous Pt electrode (1)
- principal component (1)
- probabilistic fracture mechanics (1)
- protein (1)
- quantum charging (1)
- reliability (1)
- reliability analysis (1)
- rhAPC (1)
- screen-printing (1)
- second-order reliability method (1)
- self-aligned patterning (1)
- semantic role labeling (1)
- sensing properties (1)
- shakedown analyses (1)
- shotgun sequencing (1)
- speaker attribution (1)
- sterilisation (1)
- sterility tests (1)
- sterilization efficacy (1)
- sterilization methods (1)
- subsurface ice research (1)
- subsurface probe (1)
- surface modification (1)
- swift heavy ions (1)
- tension–torsion loading (1)
- thermal ratcheting (1)
- thick-film technology (1)
- thin-film microsensors (1)
- titanium dioxide photoanode (1)
- ultrathin gate insulators (1)
- validation methods (1)
- vessels (1)
- voltammetry (1)
- wafer-level testing (1)
- water bridge phenomenon (1)
- wound healing (1)
- yield stress (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (123) (remove)
In this work, the bioabsorbable materials, namely fibroin, polylactide acid (PLA), magnesium and magnesium oxide are investigated for their application as transient, resistive temperature detectors (RTD). For this purpose, a thin-film magnesium-based meander-like electrode is deposited onto a flexible, bioabsorbable substrate (fibroin or PLA) and encapsulated (passivated) by additional magnesium oxide layers on top and below the magnesium-based electrode. The morphology of different layered RTDs is analyzed by scanning electron microscopy. The sensor performance and lifetime of the RTD is characterized both under ambient atmospheric conditions between 30°C and 43°C, and wet tissue-like conditions with a constant temperature regime of 37°C. The latter triggers the degradation process of the magnesium-based layers. The 3-layers RTDs on a PLA substrate could achieve a lifetime of 8.5 h. These sensors also show the best sensor performance under ambient atmospheric conditions with a mean sensitivity of 0.48 Ω/°C ± 0.01 Ω/°C.
In comparison to single-analyte devices, multiplexed systems for a multianalyte detection offer a reduced assay time and sample volume, low cost, and high throughput. Herein, a multiplexing platform for an automated quasi-simultaneous characterization of multiple (up to 16) capacitive field-effect sensors by the capacitive–voltage (C–V) and the constant-capacitance (ConCap) mode is presented. The sensors are mounted in a newly designed multicell arrangement with one common reference electrode and are electrically connected to the impedance analyzer via the base station. A Python script for the automated characterization of the sensors executes the user-defined measurement protocol. The developed multiplexing system is tested for pH measurements and the label-free detection of ligand-stabilized, charged gold nanoparticles.
The growing body of political texts opens up new opportunities for rich insights into political dynamics and ideologies but also increases the workload for manual analysis. Automated speaker attribution, which detects who said what to whom in a speech event and is closely related to semantic role labeling, is an important processing step for computational text analysis. We study the potential of the large language model family Llama 2 to automate speaker attribution in German parliamentary debates from 2017-2021. We fine-tune Llama 2 with QLoRA, an efficient training strategy, and observe our approach to achieve competitive performance in the GermEval 2023 Shared Task On Speaker Attribution in German News Articles and Parliamentary Debates. Our results shed light on the capabilities of large language models in automating speaker attribution, revealing a promising avenue for computational analysis of political discourse and the development of semantic role labeling systems.