Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1926)
- Fachbereich Elektrotechnik und Informationstechnik (1149)
- Fachbereich Wirtschaftswissenschaften (1119)
- Fachbereich Energietechnik (1066)
- Fachbereich Chemie und Biotechnologie (892)
- Fachbereich Maschinenbau und Mechatronik (800)
- Fachbereich Luft- und Raumfahrttechnik (768)
- Fachbereich Bauingenieurwesen (664)
- IfB - Institut für Bioengineering (625)
- INB - Institut für Nano- und Biotechnologien (585)
Has Fulltext
- no (9276) (remove)
Language
Document Type
- Article (5514)
- Conference Proceeding (1413)
- Book (1057)
- Part of a Book (555)
- Patent (174)
- Bachelor Thesis (165)
- Report (82)
- Doctoral Thesis (79)
- Conference: Meeting Abstract (75)
- Other (67)
- Contribution to a Periodical (20)
- Review (18)
- Master's Thesis (17)
- Working Paper (13)
- Conference Poster (5)
- Habilitation (5)
- Preprint (5)
- Talk (5)
- Diploma Thesis (3)
- Part of a Periodical (2)
- Examination Thesis (1)
- Video (1)
Keywords
- Illustration (10)
- Nachhaltigkeit (10)
- Corporate Design (9)
- Erscheinungsbild (8)
- Gamification (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Deutschland (6)
- Digitalisierung (6)
Mechanical forces/tensile stresses are critical determinants of cellular growth, differentiation and migration patterns in health and disease. The innovative “CellDrum technology” was designed for measuring mechanical tensile stress of cultured cell monolayers/thin tissue constructs routinely. These are cultivated on very thin silicone membranes in the so-called CellDrum. The cell layers adhere firmly to the membrane and thus transmit the cell forces generated. A CellDrum consists of a cylinder which is sealed from below with a 4 μm thick, biocompatible, functionalized silicone membrane. The weight of cell culture medium bulbs the membrane out downwards. Membrane indentation is measured. When cells contract due to drug action, membrane, cells and medium are lifted upwards. The induced indentation changes allow for lateral drug induced mechanical tension quantification of the micro-tissues. With hiPS-induced (human) Cardiomyocytes (CM) the CellDrum opens new perspectives of individualized cardiac drug testing. Here, monolayers of self-beating hiPS-CMs were grown in CellDrums. Rhythmic contractions of the hiPS-cells induce membrane up-and-down deflections. The recorded cycles allow for single beat amplitude, single beat duration, integration of the single beat amplitude over the beat time and frequency analysis. Dose effects of agonists and antagonists acting on Ca2+ channels were sensitively and highly reproducibly observed. Data were consistent with published reference data as far as they were available. The combination of the CellDrum technology with hiPS-Cardiomyocytes offers a fast, facile and precise system for pharmacological and toxicological studies. It allows new preclinical basic as well as applied research in pharmacolgy and toxicology.
The overall objective of this study is to develop a new external fixator, which closely maps the native kinematics of the elbow to decrease the joint force resulting in reduced rehabilitation time and pain. An experimental setup was designed to determine the native kinematics of the elbow during flexion of cadaveric arms. As a preliminary study, data from literature was used to modify a published biomechanical model for the calculation of the joint and muscle forces. They were compared to the original model and the effect of the kinematic refinement was evaluated. Furthermore, the obtained muscle forces were determined in order to apply them in the experimental setup. The joint forces in the modified model differed slightly from the forces in the original model. The muscle force curves changed particularly for small flexion angles but their magnitude for larger angles was consistent.
Im Rahmen des europäischen Verbundprojekts INSYSME wurden von den deutschen Partnern die Systeme IMES und INODIS zur Verbesserung des seismischen Verhaltens von ausgefachten Stahlbetonrahmen entwickelt. Ziel beider Systeme ist es, Stahlbetonrahmen und Ausfachung zu entkoppeln, anstatt die Tragfähigkeit durch aufwendige und kostspielige zusätzliche Bewehrungseinlagen zu erhöhen. Erste Ergebnisse des Systems IMES für Belastungen in und senkrecht zu der Wandebene werden vorgestellt.
The quest for life on other planets is closely connected with the search for water in liquid state. Recent discoveries of deep oceans on icy moons like Europa and Enceladus have spurred an intensive discussion about how these waters can be accessed. The challenge of this endeavor lies in the unforeseeable requirements on instrumental characteristics both with respect to the scientific and technical methods. The TRIPLE/nanoAUV initiative is aiming at developing a mission concept for exploring exo-oceans and demonstrating the achievements in an earth-analogue context, exploring the ocean under the ice shield of Antarctica and lakes like Dome-C on the Antarctic continent.
Pelvic floor dysfunction (PFD) is characterized by the failure of the levator ani (LA) muscle to maintain the pelvic hiatus, resulting in the descent of the pelvic organs below the pubococcygeal line. This chapter adopts the modified Humphrey material model to consider the effect of the muscle fiber on passive stretching of the LA muscle. The deformation of the LA muscle subjected to intra-abdominal pressure during Valsalva maneuver is compared with the magnetic resonance imaging (MRI) examination of a nulliparous female. Numerical result shows that the fiber-based Humphrey model simulates the muscle behavior better than isotropic constitutive models. Greater posterior movement of the LA muscle widens the levator hiatus due to lack of support from the anococcygeal ligament and the perineal structure as a consequence of birth-related injury and aging. Old and multiparous females with uncontrolled urogenital and rectal hiatus tend to develop PFDs such as prolapse and incontinence.
Wireless CAN
(2018)
In modernen elektronischen und mechatronischen Systemen, z. B. im industriellen oder automobil Bereich, kommunizieren eingebettete Steuergeräte und Sensoren vielfach über Bussysteme wie CAN oder LIN. Die Kommunikation findet in der Regel drahtgebunden statt, so dass der Kabelbaum für die Kommunikation sehr groß werden kann. Daher ist es naheliegend, Leitungen und dazugehörige Stecker, z. B. für nicht-sicherheitskritische Komfortsysteme, einzusparen und diese durch gerichtete Funkstrecken für kurze Entfernungen zu ersetzen. Somit könnten Komponenten wie ECUs oder Sensoren kabel- und steckerlos in ein Bussystem integriert werden. Zudem ist eine einfache galvanische und mechanische Trennung zu erreichen. Funkübertragung wird bei diesen Bussystemen derzeit nicht eingesetzt, da insbesondere die Echtzeitfähigkeit und die Robustheit der vorhandenen Funksysteme nicht den Anforderungen der Anwendungen entspricht. Zudem sind bestehende Funksysteme wie WLAN oder Bluetooth im Vergleich zur konventionellen Verkabelung teuer und es besteht hierbei die Möglichkeit, dass sie ausspioniert werden können und so sensible Daten entwendet werden können. In dieser Arbeit wird eine alternative Realisierung zu den bestehenden Funksystemen vorgestellt, die aus wenigen Komponenten aufzubauen ist. Es ist eine protokolllose, echtzeitfähige Übertragung möglich und somit die transparente Integration in ein Bussystem wie CAN.
Human-induced pluripotent stem cell-derived cardiomyocytes (hiPS-CM) today are widely used for the investigation of normal electromechanical cardiac function, of cardiac medication and of mutations. Computational models are thus established that simulate the behavior of this kind of cells. This section first motivates the modeling of hiPS-CM and then presents and discusses several modeling approaches of microscopic and macroscopic constituents of human-induced pluripotent stem cell-derived and mature human cardiac tissue. The focus is led on the mapping of the computational results one can achieve with these models onto mature human cardiomyocyte models, the latter being the real matter of interest. Model adaptivity is the key feature that is discussed because it opens the way for modeling various biological effects like biological variability, medication, mutation and phenotypical expression. We compare the computational with experimental results with respect to normal cardiac function and with respect to inotropic and chronotropic drug effects. The section closes with a discussion on the status quo of the specificity of computational models and on what challenges have to be solved to reach patient-specificity.
The light-addressable potentiometric sensor (LAPS) and scanning photo-induced impedance microscopy (SPIM) are two closely related methods to visualise the distributions of chemical species and impedance, respectively, at the interface between the sensing surface and the sample solution. They both have the same field-effect structure based on a semiconductor, which allows spatially resolved and label-free measurement of chemical species and impedance in the form of a photocurrent signal generated by a scanning light beam. In this article, the principles and various operation modes of LAPS and SPIM, functionalisation of the sensing surface for measuring various species, LAPS-based chemical imaging and high-resolution sensors based on silicon-on-sapphire substrates are described and discussed, focusing on their technical details and prospective applications.
Retrofitting of existing parabolic trough collector power plants with molten salt tower systems
(2018)
On the flight performance impact of landing gear drag reduction methods for unmanned air vehicles
(2018)
The flight performance impact of three different landing gear configurations on a small, fixed-wing UAV is analyzed with a combination of RANS CFD calculations and an incremental flight performance algorithm. A standard fixed landing gear configuration is taken as a baseline, while the influence of retracting the landing gear or applying streamlined fairings is investigated. A retraction leads to a significant parasite drag reduction, while also fairings promise large savings. The increase in lift-to-drag ratio is reduced at high lift coefficients due to the influence of induced drag. All configurations are tested on three different design missions with an incremental flight performance algorithm. A trade-off study is performed using the retracted or faired landing gear's weight increase as a variable. The analysis reveals only small mission performance gains as the aerodynamic improvements are negated by weight penalties. A new workflow for decision-making is presented that allows to estimate if a change in landing gear configuration is beneficial for a small UAV.
A chip-based amperometric biosensor referring on using the bioelectrocatalytical amplification principle for the detection of low adrenaline concentrations is presented. The adrenaline biosensor has been prepared by modification of a platinum thin-film electrode with an enzyme membrane containing the pyrroloquinoline quinone-dependent glucose dehydrogenase and glutaraldehyde. Measuring conditions such as temperature, pH value, and glucose concentration have been optimized to achieve a high sensitivity and a low detection limit of about 1 nM adrenaline measured in phosphate buffer at neutral pH value. The response of the biosensor to different catecholamines has also been proven. Long-term stability of the adrenaline biosensor has been studied over 10 days. In addition, the biosensor has been successfully applied for adrenaline detection in human blood plasma for future biomedical applications. Furthermore, preliminary experiments have been carried to detect the adrenaline-concentration difference measured in peripheral blood and adrenal venous blood, representing the adrenal vein sampling procedure of a physician.
Reconstructive surgery and tissue replacements like ureters or bladders reconstruction have been recently studied, taking into account growth and remodelling of cells since living cells are capable of growing, adapting, remodelling or degrading and restoring in order to deform and respond to stimuli. Hence, shapes of ureters or bladders and their microstructure change during growth and these changes strongly depend on external stimuli such as training. We present the mechanical stimulation of smooth muscle cells in a tubular fibrin-PVDFA scaffold and the modelling of the growth of tissue by stimuli. To this end, mechanotransduction was performed with a kyphoplasty balloon catheter that was guided through the lumen of the tubular structure. The bursting pressure was examined to compare the stability of the incubated tissue constructs. The results showed the significant changes on tissues with training by increasing the burst pressure as a characteristic mechanical property and the smooth muscle cells were more oriented with uniformly higher density. Besides, the computational growth models also exhibited the accurate tendencies of growth of the cells under different external stimuli. Such models may lead to design standards for the better layered tissue structure in reconstructing of tubular organs characterized as composite materials such as intestines, ureters and arteries.
The presentation of enzymes on viral scaffolds has beneficial effects such as an increased enzyme loading and a prolonged reusability in comparison to conventional immobilization platforms. Here, we used modified tobacco mosaic virus (TMV) nanorods as enzyme carriers in penicillin G detection for the first time. Penicillinase enzymes were conjugated with streptavidin and coupled to TMV rods by use of a bifunctional biotin-linker. Penicillinase-decorated TMV particles were characterized extensively in halochromic dye-based biosensing. Acidometric analyte detection was performed with bromcresol purple as pH indicator and spectrophotometry. The TMV-assisted sensors exhibited increased enzyme loading and strongly improved reusability, and higher analysis rates compared to layouts without viral adapters. They extended the half-life of the sensors from 4 - 6 days to 5 weeks and thus allowed an at least 8-fold longer use of the sensors. Using a commercial budget-priced penicillinase preparation, a detection limit of 100 µM penicillin was obtained. Initial experiments also indicate that the system may be transferred to label-free detection layouts.
Nanotubular tobacco mosaic virus (TMV) particles and RNA-free lower-order coat protein (CP) aggregates have been employed as enzyme carriers in different diagnostic layouts and compared for their influence on biosensor performance. In the following, we describe a label-free electrochemical biosensor for improved glucose detection by use of TMV adapters and the enzyme glucose oxidase (GOD). A specific and efficient immobilization of streptavidin-conjugated GOD ([SA]-GOD) complexes on biotinylated TMV nanotubes or CP aggregates was achieved via bioaffinity binding. Glucose sensors with adsorptively immobilized [SA]-GOD, and with [SA]-GOD cross-linked with glutardialdehyde, respectively, were tested in parallel on the same sensor chip. Comparison of these sensors revealed that TMV adapters enhanced the amperometric glucose detection remarkably, conveying highest sensitivity, an extended linear detection range and fastest response times. These results underline a great potential of an integration of virus/biomolecule hybrids with electronic transducers for applications in biosensorics and biochips. Here, we describe the fabrication and use of amperometric sensor chips combining an array of circular Pt electrodes, their loading with GOD-modified TMV nanotubes (and other GOD immobilization methods), and the subsequent investigations of the sensor performance.
Cloud Computing wirft in zahlreichen Rechtsbereichen neuartige juristische Fragestellungen auf. Ziel der Darstellung der rechtlichen Rahmenbedingungen ist, die das Identitätsmanagement in der Cloud betreffenden Rechtsgrundlagen aus den unterschiedlichen Rechtsgebieten vorzustellen und einzuordnen, bevor im Rahmen des sechsten Kapitels die Darstellung der hieraus resultierenden Verpflichtungen in ihrer konkreten Form erfolgt.