Refine
Year of publication
- 2024 (7)
- 2023 (20)
- 2022 (12)
- 2021 (25)
- 2020 (20)
- 2019 (30)
- 2018 (35)
- 2017 (25)
- 2016 (26)
- 2015 (22)
- 2014 (24)
- 2013 (29)
- 2012 (24)
- 2011 (31)
- 2010 (26)
- 2009 (27)
- 2008 (27)
- 2007 (28)
- 2006 (17)
- 2005 (15)
- 2004 (19)
- 2003 (12)
- 2002 (20)
- 2001 (20)
- 2000 (19)
- 1999 (23)
- 1998 (16)
- 1997 (13)
- 1996 (10)
- 1995 (11)
- 1994 (15)
- 1993 (9)
- 1992 (8)
- 1991 (4)
- 1990 (6)
- 1989 (5)
- 1988 (5)
- 1987 (2)
- 1986 (1)
- 1985 (6)
- 1984 (1)
- 1982 (2)
- 1981 (1)
- 1980 (4)
- 1979 (2)
- 1978 (3)
- 1976 (1)
- 1975 (1)
- 1974 (1)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (710) (remove)
Has Fulltext
- no (710) (remove)
Language
- English (710) (remove)
Document Type
- Article (412)
- Conference Proceeding (228)
- Part of a Book (38)
- Book (23)
- Conference: Meeting Abstract (5)
- Patent (2)
- Conference Poster (1)
- Doctoral Thesis (1)
Keywords
- Enterprise Architecture (5)
- MINLP (5)
- Engineering optimization (4)
- Optimization (3)
- Powertrain (3)
- Technical Operations Research (3)
- Telecommunication (3)
- Competence Developing Games (2)
- Energy efficiency (2)
- Engineering education (2)
Control mechanisms like Industrial Controls Systems (ICS) and its subgroup SCADA (Supervisory Control and Data Acquisition) are a prerequisite to automate industrial processes. While protection of ICS on process management level is relatively straightforward – well known office IT security mechanisms can be used – protection on field bus level is harder to achieve as there are real-time and production requirements like 24x7 to consider. One option to improve security on field bus level is to introduce controls that help to detect and to react on attacks. This paper introduces an initial set of intrusion detection mechanisms for the field bus protocol EtherCAT. To this end existing Ethernet attack vectors including packet injection and man-in-the-middle attacks are tested in an EtherCAT environment, where they could interrupt the EtherCAT network and may even cause physical damage. Based on the signatures of such attacks, a preprocessor and new rule options are defined for the open source intrusion detection system Snort demonstrating the general feasibility of intrusion detection on field bus level.
ICSs (Industrial Control Systems) and its subset SCADA systems (Supervisory Control and Data Acquisition) are getting exposed to a constant stream of new threats. The increasing importance of IT security in ICS requires viable methods to assess the security of ICS, its individual components, and its protocols. This paper presents a security analysis with focus on the communication protocols of a single PLC (Programmable Logic Controller). The PLC, a Beckhoff CX2020, is examined and new vulnerabilities of the system are revealed. Based on these findings recommendations are made to improve security of the Beckhoff system and its protocols.
Assessment of RF Safety of Transmit Coils at 7 Tesla by Experimental and Numerical Procedures (490.)
(2012)
Short term effects of magnetic resonance imaging on excitability of the motor cortex at 1.5T and 7T
(2010)
Rationale and Objectives
The increasing spread of high-field and ultra-high-field magnetic resonance imaging (MRI) scanners has encouraged new discussion of the safety aspects of MRI. Few studies have been published on possible cognitive effects of MRI examinations. The aim of this study was to examine whether changes are measurable after MRI examinations at 1.5 and 7 T by means of transcranial magnetic stimulation (TMS).
Materials and Methods
TMS was performed in 12 healthy, right-handed male volunteers. First the individual motor threshold was specified, and then the cortical silent period (SP) was measured. Subsequently, the volunteers were exposed to the 1.5-T MRI scanner for 63 minutes using standard sequences. The MRI examination was immediately followed by another TMS session. Fifteen minutes later, TMS was repeated. Four weeks later, the complete setting was repeated using a 7-T scanner. Control conditions included lying in the 1.5-T scanner for 63 minutes without scanning and lying in a separate room for 63 minutes. TMS was performed in the same way in each case. For statistical analysis, Wilcoxon's rank test was performed.
Results
Immediately after MRI exposure, the SP was highly significantly prolonged in all 12 subjects at 1.5 and 7 T. The motor threshold was significantly increased. Fifteen minutes after the examination, the measured value tended toward normal again. Control conditions revealed no significant differences.
Conclusion
MRI examinations lead to a transient and highly significant alteration in cortical excitability. This effect does not seem to depend on the strength of the static magnetic field.
Purpose
To assess potential cognitive deficits under the influence of static magnetic fields at various field strengths some studies already exist. These studies were not focused on attention as the most vulnerable cognitive function. Additionally, mostly no magnetic resonance imaging (MRI) sequences were performed.
Materials and Methods
In all, 25 right-handed men were enrolled in this study. All subjects underwent one MRI examination of 63 minutes at 1.5 T and one at 7 T within an interval of 10 to 30 days. The order of the examinations was randomized. Subjects were referred to six standardized neuropsychological tests strictly focused on attention immediately before and after each MRI examination. Differences in neuropsychological variables between the timepoints before and after each MRI examination were assessed and P-values were calculated
Results
Only six subtests revealed significant differences between pre- and post-MRI. In these tests the subjects achieved better results in post-MRI testing than in pre-MRI testing (P = 0.013–0.032). The other tests revealed no significant results.
Conclusion
The improvement in post-MRI testing is only explicable as a result of learning effects. MRI examinations, even in ultrahigh-field scanners, do not seem to have any persisting influence on the attention networks of human cognition immediately after exposure.
The development and analysis of three waveguides for the exposure of small biological in vitro samples to mobile communication signals at 900 MHz (GSM, Global System for Mobile Communications), 1.8 GHz (GSM), and 2 GHz (UMTS, Universal Mobile Telecommunications System) is presented. The waveguides were based on a fin-line concept and the chamber containing the samples bathed in extracellular solution was placed onto two fins with a slot in between, where the exposure field concentrates. Measures were taken to allow for patch clamp recordings during radiofrequency (RF) exposure. The necessary power for the achievement of the maximum desired specific absorption rate (SAR) of 20 W/kg (average over the mass of the solution) was approximately Pin = 50 mW, Pin = 19 mW, and Pin = 18 mW for the 900 MHz, 1800 MHz, and 2 GHz devices, respectively. At 20 W/kg, a slight RF-induced temperature elevation in the solution of no more than 0.3 °C was detected, while no thermal offsets due to the electromagnetic exposure could be detected at the lower SAR settings (2, 0.2, and 0.02 W/kg). A deviation of 10% from the intended solution volume yielded a calculated SAR deviation of 8% from the desired value. A maximum ±10% variation in the local SAR could occur when the position of the patch clamp electrode was altered within the area where the cells to be investigated were located.