Article
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1593)
- Fachbereich Wirtschaftswissenschaften (705)
- Fachbereich Elektrotechnik und Informationstechnik (638)
- Fachbereich Energietechnik (609)
- Fachbereich Chemie und Biotechnologie (602)
- INB - Institut für Nano- und Biotechnologien (542)
- Fachbereich Maschinenbau und Mechatronik (484)
- IfB - Institut für Bioengineering (451)
- Fachbereich Luft- und Raumfahrttechnik (380)
- Fachbereich Bauingenieurwesen (333)
Language
Document Type
- Article (5646) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- Multimediamarkt (6)
- Rapid prototyping (5)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- Rapid Prototyping (4)
- biosensors (4)
Two types of microvalves based on temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm) and pH-responsive poly(sodium acrylate) (PSA) hydrogel films have been developed and tested. The PNIPAAm and PSA hydrogel films were prepared by means of in situ photopolymerization directly inside the fluidic channel of a microfluidic chip fabricated by combining Si and SU-8 technologies. The swelling/shrinking properties and height changes of the PNIPAAm and PSA films inside the fluidic channel were studied at temperatures of deionized water from 14 to 36 °C and different pH values (pH 3–12) of Titrisol buffer, respectively. Additionally, in separate experiments, the lower critical solution temperature (LCST) of the PNIPAAm hydrogel was investigated by means of a differential scanning calorimetry (DSC) and a surface plasmon resonance (SPR) method. Mass-flow measurements have shown the feasibility of the prepared hydrogel films to work as an on-chip integrated temperature- or pH-responsive microvalve capable to switch the flow channel on/off.
Smartphone Forensik
(2012)
Label-free electrical detection of consecutive deoxyribonucleic acid (DNA) hybridization/denaturation by means of an array of individually addressable field-effect-based nanoplate silicon-on-insulator (SOI) capacitors modified with gold nanoparticles (Au-NP) is investigated. The proposed device detects charge changes on Au-NP/DNA hybrids induced by the hybridization or denaturation event. DNA hybridization was performed in a high ionic-strength solution to provide a high hybridization efficiency. On the other hand, to reduce the screening of the DNA charge by counter ions and to achieve a high sensitivity, the sensor signal induced by the hybridization and denaturation events was measured in a low ionic-strength solution. High sensor signals of about 120, 90, and 80 mV were registered after the DNA hybridization, denaturation, and re-hybridization events, respectively. Fluorescence microscopy has been applied as reference method to verify the DNA immobilization, hybridization, and denaturation processes. An electrostatic charge-plane model for potential changes at the gate surface of a nanoplate field-effect sensor induced by the DNA hybridization has been developed taking into account both the Debye length and the distance of the DNA charge from the gate surface.