Refine
Year of publication
Institute
- Fachbereich Elektrotechnik und Informationstechnik (710) (remove)
Has Fulltext
- no (710) (remove)
Language
- English (710) (remove)
Document Type
- Article (412)
- Conference Proceeding (228)
- Part of a Book (38)
- Book (23)
- Conference: Meeting Abstract (5)
- Patent (2)
- Conference Poster (1)
- Doctoral Thesis (1)
Keywords
- Enterprise Architecture (5)
- MINLP (5)
- Engineering optimization (4)
- Optimization (3)
- Powertrain (3)
- Technical Operations Research (3)
- Telecommunication (3)
- Competence Developing Games (2)
- Energy efficiency (2)
- Engineering education (2)
- Experimental validation (2)
- Gamification (2)
- Hot S-parameter (2)
- Machine Learning (2)
- Optimal Topology (2)
- Process engineering (2)
- Pump System (2)
- Robotic Process Automation (2)
- Serious Game (2)
- Ventilation System (2)
- Water (2)
- Water distribution system (2)
- autonomous driving (2)
- mathematical optimization (2)
- robotic process automation (2)
- 197m/gHg (1)
- 3-D printing (1)
- 3D object detection (1)
- Accuracy (1)
- Advanced driver assistance systems (ADAS/AD) (1)
- Agile development (1)
- Agility (1)
- Android (1)
- Angle Sensor (1)
- Anomaly detection (1)
- Artificial Intelligence (1)
- Automated driving (1)
- Automation (1)
- Automotive application (1)
- Autonomous mobile robots (1)
- Awareness (1)
- BEV (1)
- Benchmark (1)
- Bloom’s Taxonomy (1)
- Booster Stations (1)
- Buffering Capacity (1)
- Building Automation (1)
- Business Engineering (1)
- Business Process (1)
- CAV (1)
- CDG (1)
- CO2 (1)
- Carbon Dioxide (1)
- Cardiovascular Magnetic Resonance (1)
- Case Study (1)
- Case study (1)
- Chance Constraint (1)
- Change culture (1)
- Charging stations (1)
- Circuit simulation (1)
- Competence Developing Game (1)
- Computational modeling (1)
- Connected Automated Vehicle (1)
- Conpot (1)
- Control (1)
- Control engineering (1)
- Controller Parameter (1)
- Cooling system (1)
- Cryptographic protocols (1)
- Customer Orientation (1)
- DC machines (1)
- Data analysis (1)
- Data visualization (1)
- Datasets (1)
- Deep learning (1)
- Digital Age (1)
- Digital Twin Evolution (1)
- Digital transformation (1)
- Digital triage (1)
- Digital twin (1)
- Discrete Optimisation (1)
- Drinking Water Supply (1)
- E-carsharing (1)
- E-mobility (1)
- EGG (1)
- Education (1)
- Efficiency (1)
- Efficiency optimization (1)
- Electrocardiography (1)
- Electronic learning (1)
- Elicit (1)
- Energy (1)
- Energy Disaggregation (1)
- Engineering Application (1)
- Engineering optimisation (1)
- Enterprise architecture (1)
- Enterprise transformation (1)
- FPGA (1)
- Frequency Doubler (1)
- Fully connected car (1)
- Furnace (1)
- Fusion (1)
- Future Skills (1)
- GPU (1)
- Game-based learning (1)
- Gearbox (1)
- Global optimization (1)
- Gold nanoparticle (AuNP) (1)
- Graph Theory (1)
- Harmonic Radar (1)
- Heuristic algorithms (1)
- High field MRI (1)
- Home Assistant (1)
- Home Automation Platform (1)
- ICS (1)
- IP-based networks (1)
- ISO 26262 (1)
- IT security education (1)
- Image Database (1)
- Image Forensics (1)
- Image Quality Assessment (1)
- Image Quality Score (1)
- Implementation Case (1)
- Incremental Encoder (1)
- Inductive charging (1)
- Industrial optimisation (1)
- Industry 4.0 (1)
- Information and communication technology (1)
- Integrated mobility (1)
- Interactive process mining (1)
- Interdisciplinarity (1)
- Interval Time Series (1)
- Keyword analysis (1)
- LQR (1)
- Larynx position (1)
- Latin Hypercube Sampling (1)
- Leaderboard (1)
- Lean thinking (1)
- Level Control System (1)
- LiDAR (1)
- Lidar (1)
- Literature review (1)
- Low voltage (1)
- MATLAB , MLPI , Motion control , Open Core , industrial drives , rapid control prototypin , sercos automation bus (1)
- MILP (1)
- MPC (1)
- MR safety (1)
- MRI (1)
- Machine learning (1)
- Magneto alert sensor (1)
- Malicious model (1)
- Manifolds (1)
- Map (eTOM) Process reference model Process design Telecommunications industry (1)
- Matlab (1)
- Meitner-Auger-electron (MAE) (1)
- Methodology (1)
- Minimum Risk Manoeuvre (1)
- Mixed Integer Programming (1)
- Mixed-Integer Nonlinear Optimisation (1)
- Mixed-integer nonlinear black-box optimization (1)
- Mixed-integer nonlinear problem (1)
- Mixed-integer nonlinear programming (1)
- Mixed-integer programming (1)
- Mobile Phones (1)
- Mobility management (1)
- Mode converter (1)
- Modeling (1)
- Monitoring (1)
- Mpc (1)
- Multi-criteria optimization (1)
- Multi-robot systems (1)
- NGN (1)
- Navigation (1)
- Network (1)
- Network design (1)
- Neural networks (1)
- Next Generation Network (1)
- OR 2019 (1)
- Objective data (1)
- Online services (1)
- Open Source (1)
- Operational Design Domain (1)
- Optimal Closed Loop (1)
- PPO (1)
- Paper recycling (1)
- Path-following (1)
- Performance (1)
- Personality (1)
- Piecewise Linearization (1)
- Piecewise linearization (1)
- Plasma (1)
- Plasma diagnostics (1)
- Player Types (1)
- Position Encoder (1)
- Power dissipation (1)
- Preface (1)
- Privacy-enhancing technologies (1)
- Process design (1)
- Process optimization (1)
- Process reference model (1)
- Process virtualization (1)
- Product bundling (1)
- Product family optimization (1)
- Prototype (1)
- Pumping systems (1)
- Quality control (1)
- Quantum Computing (1)
- Quantum Machine Learning (1)
- Radar (1)
- Reference Process Model (1)
- Reference modelling (1)
- Reinforcement Learning (1)
- Rescue System (1)
- Research process (1)
- Resilience (1)
- Resilience Assessment (1)
- Resilience assessment (1)
- Resilience metric graph theory (1)
- Resilient infrastructure (1)
- RoboCup (1)
- Robotic process automation (1)
- Rotary encoder (1)
- Rotational Encoder (1)
- Rotatory Inverted Pendulum (1)
- Safety of the intended functionality (SOTIF) (1)
- Safety-critical systems validation (1)
- Secure multi-party computation (1)
- Self-driving (1)
- Sensors comparison (1)
- Serious Games (1)
- Services (1)
- Similarity Theory (1)
- Smart Building (1)
- Smart factory (1)
- Society (1)
- Software (1)
- Software Robots (1)
- Software development (1)
- Software packages (1)
- Software testing (1)
- Solver Per- formance (1)
- Sound Pressure Level (1)
- Stochastic Programming (1)
- Story (1)
- Stress testing (1)
- Subject-oriented Business Process Management (1)
- Sustainability (1)
- Synchronous machines (1)
- System Design (1)
- System Design Problem (1)
- TGA (1)
- TM Forum (1)
- Tag (1)
- Targeted radionuclide therapy (TRT) (1)
- Teamwork (1)
- Technical Operation Research (1)
- Telecommunication Industry (1)
- Telecommunications Industry. (1)
- Text analytics (1)
- Text mining (1)
- Three-dimensional displays (1)
- Throughput (1)
- Time-series synchronization (1)
- Tomography (1)
- Training (1)
- Transdisciplinarity (1)
- Transfer impedance (1)
- Transformation (1)
- Transformation Project (1)
- Transformative Competencies (1)
- Transiton of Control (1)
- Transponder (1)
- Triage-app (1)
- Uktrahigh field MRI (1)
- Uncertainty (1)
- Urban areas (1)
- V2X (1)
- VOP compression (1)
- Validation (1)
- Video Game (1)
- Voice assessment (1)
- WLTP (1)
- Water Distribution (1)
- Water Supply Networks (1)
- Water Supply System (1)
- Water supply system (1)
- Wearable electronic device (1)
- Wiegand Effect (1)
- Wiegand sensor (1)
- Zero-knowledge proofs (1)
- active learning (1)
- agile (1)
- anticipation strategy (1)
- applications (1)
- artificial intelligence (1)
- automated vehicles (1)
- availability (1)
- batteries and fuel cells (1)
- body imaging at 7 T MRI (1)
- body imaging at UHF MRI (1)
- business analytics (1)
- business process automation (1)
- business simulation (1)
- commercial offthe- shelf solutions (1)
- competence developing games (1)
- connected automated vehicles (1)
- culpability (1)
- cybersecurity (1)
- decision analytics (1)
- design of technical systems (1)
- digital economy (1)
- do-it-yourself (1)
- eTOM (1)
- education (1)
- electrospinning (1)
- embedded hardware (1)
- energy efficiency (1)
- energy transfer (1)
- enhanced Telecom Operations Map (eTOM) (1)
- experimental evaluation (1)
- fault detection (1)
- fibers (1)
- genetic algorithm (1)
- global optimization (1)
- harmonic radar (1)
- harmonic radar tags (1)
- heating system (1)
- honeynet (1)
- honeypot (1)
- ignition (1)
- information systems (1)
- integrated transmit coil arrays (1)
- irradiation (1)
- lab work (1)
- learning theories (1)
- legal obligations (1)
- liability (1)
- management (1)
- metrological characterization (1)
- microplasma (1)
- microwave (MW) plasma (1)
- microwave measurements (1)
- mixed-integer linear programming (1)
- model-predictive control (1)
- motivation theories (1)
- next generation network (1)
- nonlinear VNA measurements (1)
- optimization (1)
- passive inter-modulation (1)
- plasma jet (1)
- porous materials (1)
- power integrity (1)
- product bundling (1)
- product liability (1)
- professional skills (1)
- programming (1)
- remote sensing (1)
- requirements (1)
- research framework (1)
- resilience (1)
- sensor networks (1)
- signal integrity (1)
- slum classification (1)
- software engineering (1)
- software evaluation (1)
- software selection (1)
- stochastic optimization (1)
- sustainability (1)
- system optimization (1)
- system synthesis (1)
- systematic literature review (1)
- tablet game (1)
- technical operations research (1)
- technology (1)
- telecommunication (1)
- thermal dose (1)
- tissue temperature (1)
- transmit antenna arrays (1)
- water supply design (1)
- water supply system (1)
Objective
To investigate the feasibility of 7T MR imaging of the kidneys utilising a custom-built 8-channel transmit/receive radiofrequency body coil.
Methods
In vivo unenhanced MR was performed in 8 healthy volunteers on a 7T whole-body MR system. After B0 shimming the following sequences were obtained: 1) 2D and 3D spoiled gradient-echo sequences (FLASH, VIBE), 2) T1-weighted 2D in and opposed phase 3) True-FISP imaging and 4) a T2-weighted turbo spin echo (TSE) sequence. Visual evaluation of the overall image quality was performed by two radiologists.
Results
Renal MRI at 7T was feasible in all eight subjects. Best image quality was found using T1-weighted gradient echo MRI, providing high anatomical details and excellent conspicuity of the non-enhanced vasculature. With successful shimming, B1 signal voids could be effectively reduced and/or shifted out of the region of interest in most sequence types. However, T2-weighted TSE imaging remained challenging and strongly impaired because of signal heterogeneities in three volunteers.
Conclusion
The results demonstrate the feasibility and diagnostic potential of dedicated 7T renal imaging. Further optimisation of imaging sequences and dedicated RF coil concepts are expected to improve the acquisition quality and ultimately provide high clinical diagnostic value.
Purpose
To demonstrate that high quality T₂-weighted (T2w) turbo spin-echo (TSE) imaging of the complete prostate can be achieved routinely and within safety limits at 7 T, using an external transceive body array coil only.
Methods
Nine healthy volunteers and 12 prostate cancer patients were scanned on a 7 T whole-body system. Preparation consisted of B₀ and radiofrequency shimming and localized flip angle calibration. T₁ and T₂ relaxation times were measured and used to define the T2w-TSE protocol. T2w imaging was performed using a TSE sequence (pulse repetition time/echo time 3000–3640/71 ms) with prolonged excitation and refocusing pulses to reduce specific absorption rate.
Results
High quality T2w TSE imaging was performed in less than 2 min in all subjects. Tumors of patients with gold-standard tumor localization (MR-guided biopsy or prostatectomy) were well visualized on 7 T imaging (n = 3). The number of consecutive slices achievable within a 10-g averaged specific absorption rate limit of 10 W/kg was ≥28 in all subjects, sufficient for full prostate coverage with 3-mm slices in at least one direction.
Conclusion
High quality T2w TSE prostate imaging can be performed routinely and within specific absorption rate limits at 7 T with an external transceive body array.
Objectives
The aim of this study was to identify characteristics of phosphorus (³¹P) spectra of the human prostate and to investigate changes of individual phospholipid metabolites in prostate cancer through in vivo ³¹P magnetic resonance spectroscopic imaging (MRSI) at 7 T.
Materials and Methods
In this institutional review board–approved study, 15 patients with biopsy-proven prostate cancer underwent T₂-weighted magnetic resonance imaging and 3-dimensional ³¹P MRSI at 7 T. Voxels were selected at the tumor location, in normal-appearing peripheral zone tissue, normal-appearing transition zone tissue, and in the base of the prostate close to the seminal vesicles. Phosphorus metabolite ratios were determined and compared between tissue types.
Results
Signals of phosphoethanolamine (PE) and phosphocholine (PC) were present and well resolved in most ³¹P spectra in the prostate. Glycerophosphocholine signals were observable in 43% of the voxels in malignant tissue, but in only 10% of the voxels in normal-appearing tissue away from the seminal vesicles. In many spectra, independent of tissue type, 2 peaks resonated in the chemical shift range of inorganic phosphate, possibly representing 2 separate pH compartments. The PC/PE ratio in the seminal vesicles was highly elevated compared with the prostate in 5 patients. A considerable overlap of ³¹P metabolite ratios was found between prostate cancer and normal-appearing prostate tissue, preventing direct discrimination of these tissues. The only 2 patients with high Gleason scores tumors (≥4+5) presented with high PC and glycerophosphocholine levels in their cancer lesions.
Conclusions
Phosphorus MRSI at 7 T shows distinct features of phospholipid metabolites in the prostate gland and its surrounding structures. In this exploratory study, no differences in ³¹P metabolite ratios were observed between prostate cancer and normal-appearing prostate tissue possibly because of the partial volume effects of small tumor foci in large MRSI voxels.
Vestibular effects of a 7 Tesla MRI examination compared to 1.5 T and 0 T in healthy volunteers
(2014)
Ultra-high-field MRI (7 Tesla (T) and above) elicits more temporary side-effects compared to 1.5 T and 3 T, e.g. dizziness or “postural instability” even after exiting the scanner. The current study aims to assess quantitatively vestibular performance before and after exposure to different MRI scenarios at 7 T, 1.5 T and 0 T. Sway path and body axis rotation (Unterberger's stepping test) were quantitatively recorded in a total of 46 volunteers before, 2 minutes after, and 15 minutes after different exposure scenarios: 7 T head MRI (n = 27), 7 T no RF (n = 22), 7 T only B₀ (n = 20), 7 T in & out B₀ (n = 20), 1.5 T no RF (n = 20), 0 T (n = 15). All exposure scenarios lasted 30 minutes except for brief one minute exposure in 7 T in & out B₀. Both measures were documented utilizing a 3D ultrasound system. During sway path evaluation, the experiment was repeated with eyes both open and closed. Sway paths for all long-lasting 7 T scenarios (normal, no RF, only B₀) with eyes closed were significantly prolonged 2 minutes after exiting the scanner, normalizing after 15 minutes. Brief exposure to 7 T B₀ or 30 minutes exposure to 1.5 T or 0 T did not show significant changes. End positions after Unterberger's stepping test were significantly changed counter-clockwise after all 7 T scenarios, including the brief in & out B₀ exposure. Shorter exposure resulted in a smaller alteration angle. In contrast to sway path, reversal of changes in body axis rotation was incomplete after 15 minutes. 1.5 T caused no rotational changes. The results show that exposure to the 7 Tesla static magnetic field causes only a temporary dysfunction or “over-compensation” of the vestibular system not measurable at 1.5 or 0 Tesla. Radiofrequency fields, gradient switching, and orthostatic dysregulation do not seem to play a role.
Objectives
To assess the image quality of T2-weighted (T2w) magnetic resonance imaging of the prostate and the visibility of prostate cancer at 7 Tesla (T).
Materials & methods
Seventeen prostate cancer patients underwent T2w imaging at 7T with only an external transmit/receive array coil. Three radiologists independently scored images for image quality, visibility of anatomical structures, and presence of artefacts. Krippendorff’s alpha and weighted kappa statistics were used to assess inter-observer agreement. Visibility of prostate cancer lesions was assessed by directly linking the T2w images to the confirmed location of prostate cancer on histopathology.
Results
T2w imaging at 7T was achievable with ‘satisfactory’ (3/5) to ‘good’ (4/5) quality. Visibility of anatomical structures was predominantly scored as ‘satisfactory’ (3/5) and ‘good’ (4/5). If artefacts were present, they were mostly motion artefacts and, to a lesser extent, aliasing artefacts and noise. Krippendorff’s analysis revealed an α = 0.44 between three readers for the overall image quality scores. Clinically significant cancer lesions in both peripheral zone and transition zone were visible at 7T.
Conclusion
T2w imaging with satisfactory to good quality can be routinely acquired, and cancer lesions were visible in patients with prostate cancer at 7T using only an external transmit/receive body array coil.
Purpose
To assess the feasibility of prostate ¹H MR spectroscopic imaging (MRSI) using low-power spectral-spatial (SPSP) pulses at 7T, exploiting accurate spectral selection and spatial selectivity simultaneously.
Methods
A double spin-echo sequence was equipped with SPSP refocusing pulses with a spectral selectivity of 1 ppm. Three-dimensional prostate ¹H-MRSI at 7T was performed with the SPSP-MRSI sequence using an 8-channel transmit array coil and an endorectal receive coil in three patients with prostate cancer and in one healthy subject. No additional water or lipid suppression pulses were used.
Results
Prostate ¹H-MRSI could be obtained well within specific absorption rate (SAR) limits in a clinically feasible time (10 min). Next to the common citrate signals, the prostate spectra exhibited high spermine signals concealing creatine and sometimes also choline. Residual lipid signals were observed at the edges of the prostate because of limitations in spectral and spatial selectivity.
Conclusion
It is possible to perform prostate ¹H-MRSI at 7T with a SPSP-MRSI sequence while using separate transmit and receive coils. This low-SAR MRSI concept provides the opportunity to increase spatial resolution of MRSI within reasonable scan times.
Compared to peripheral pain, trigeminal pain elicits higher levels of fear, which is assumed to enhance the interruptive effects of pain on concomitant cognitive processes. In this fMRI study we examined the behavioral and neural effects of trigeminal (forehead) and peripheral (hand) pain on visual processing and memory encoding. Cerebral activity was measured in 23 healthy subjects performing a visual categorization task that was immediately followed by a surprise recognition task. During the categorization task subjects received concomitant noxious electrical stimulation on the forehead or hand. Our data show that fear ratings were significantly higher for trigeminal pain. Categorization and recognition performance did not differ between pictures that were presented with trigeminal and peripheral pain. However, object categorization in the presence of trigeminal pain was associated with stronger activity in task-relevant visual areas (lateral occipital complex, LOC), memory encoding areas (hippocampus and parahippocampus) and areas implicated in emotional processing (amygdala) compared to peripheral pain. Further, individual differences in neural activation between the trigeminal and the peripheral condition were positively related to differences in fear ratings between both conditions. Functional connectivity between amygdala and LOC was increased during trigeminal compared to peripheral painful stimulation. Fear-driven compensatory resource activation seems to be enhanced for trigeminal stimuli, presumably due to their exceptional biological relevance.
Objective
This study assesses and quantifies impairment of postoperative magnetic resonance imaging (MRI) at 7 Tesla (T) after implantation of titanium cranial fixation plates (CFPs) for neurosurgical bone flap fixation.
Materials and methods
The study group comprised five patients who were intra-individually examined with 3 and 7 T MRI preoperatively and postoperatively (within 72 h/3 months) after implantation of CFPs. Acquired sequences included T₁-weighted magnetization-prepared rapid-acquisition gradient-echo (MPRAGE), T₂-weighted turbo-spin-echo (TSE) imaging, and susceptibility-weighted imaging (SWI). Two experienced neurosurgeons and a neuroradiologist rated image quality and the presence of artifacts in consensus reading.
Results
Minor artifacts occurred around the CFPs in MPRAGE and T2 TSE at both field strengths, with no significant differences between 3 and 7 T. In SWI, artifacts were accentuated in the early postoperative scans at both field strengths due to intracranial air and hemorrhagic remnants. After resorption, the brain tissue directly adjacent to skull bone could still be assessed. Image quality after 3 months was equal to the preoperative examinations at 3 and 7 T.
Conclusion
Image quality after CFP implantation was not significantly impaired in 7 T MRI, and artifacts were comparable to those in 3 T MRI.
Purpose
To calculate local specific absorption rate (SAR) correctly, both the amplitude and phase of the signal in each transmit channel have to be known. In this work, we propose a method to derive a conservative upper bound for the local SAR, with a reasonable safety margin without knowledge of the transmit phases of the channels.
Methods
The proposed method uses virtual observation points (VOPs). Correction factors are calculated for each set of VOPs that prevent underestimation of local SAR when the VOPs are applied with the correct amplitudes but fixed phases.
Results
The proposed method proved to be superior to the worst-case calculation based on the maximum eigenvalue of the VOPs. The mean overestimation for six coil setups could be reduced, whereas no underestimation of the maximum local SAR occurred. In the best investigated case, the overestimation could be reduced from a factor of 3.3 to a factor of 1.7.
Conclusion
The upper bound for the local SAR calculated with the proposed method allows a fast estimation of the local SAR based on power measurements in the transmit channels and facilitates SAR monitoring in systems that do not have the capability to monitor transmit phases
SAR Simulations & Safety
(2017)
This summer, RoboCup competitions were held for the 20th time in Leipzig, Germany. It was the second time that RoboCup took place in Germany, 10 years after the 2006 RoboCup in Bremen. In this article, we give an overview on the latest developments of RoboCup and what happened in the different leagues over the last decade. With its 20th edition, RoboCup clearly is a success story and a role model for robotics competitions. From our personal view point, we acknowledge this by giving a retrospection about what makes RoboCup such a success.