Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1928)
- Fachbereich Elektrotechnik und Informationstechnik (1150)
- Fachbereich Wirtschaftswissenschaften (1119)
- Fachbereich Energietechnik (1066)
- Fachbereich Chemie und Biotechnologie (892)
- Fachbereich Maschinenbau und Mechatronik (801)
- Fachbereich Luft- und Raumfahrttechnik (769)
- Fachbereich Bauingenieurwesen (664)
- IfB - Institut für Bioengineering (627)
- INB - Institut für Nano- und Biotechnologien (585)
Has Fulltext
- no (9284) (remove)
Language
Document Type
- Article (5518)
- Conference Proceeding (1413)
- Book (1057)
- Part of a Book (555)
- Patent (174)
- Bachelor Thesis (169)
- Report (82)
- Doctoral Thesis (79)
- Conference: Meeting Abstract (75)
- Other (67)
- Contribution to a Periodical (20)
- Review (18)
- Master's Thesis (17)
- Working Paper (13)
- Conference Poster (5)
- Habilitation (5)
- Preprint (5)
- Talk (5)
- Diploma Thesis (3)
- Part of a Periodical (2)
- Examination Thesis (1)
- Video (1)
Keywords
- Illustration (10)
- Nachhaltigkeit (10)
- Corporate Design (9)
- Erscheinungsbild (8)
- Gamification (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Deutschland (6)
- Digitalisierung (6)
A novel photoexcitation method for the light-addressable potentiometric sensor (LAPS) realized a higher spatial resolution of chemical imaging. In this method, a modulated light probe, which generates the alternating photocurrent signal, is surrounded by a ring of constant light, which suppresses the lateral diffusion of photocarriers by enhancing recombination. A device simulation verified that a higher spatial resolution could be obtained by adjusting the gap between the modulated and constant light. It was also found that a higher intensity and a longer wavelength of constant light was more effective. However, there exists a tradeoff between the spatial resolution and the amplitude of the photocurrent, and thus, the signal-to-noise ratio. A tilted incidence of constant light was applied, which could achieve even higher resolution with a smaller loss of photocurrent.
A semiconductor field-effect device has been used for an enzymatically catalyzed degradation of biopolymers for the first time. This novel technique is capable to monitor the degradation process of multiple samples in situ and in real-time. As model system, the degradation of the biopolymer poly(D, L-lactic acid) has been monitored in the degradation medium containing the enzyme lipase from Rhizomucor miehei. The obtained results demonstrate the potential of capacitive field-effect sensors for degradation studies of biodegradable polymers.
High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors for liquids. In this work, BST films have been applied as a sensitive transducer material for a label-free detection of adsorbed charged macromolecules (positively charged polyelectrolytes) and concentration of hydrogen peroxide vapor as well as protection insulator layer for a contactless electrolyte-conductivity sensor. The experimental results of characterization of individual sensors are presented. Special emphasis is devoted towards the development of a capacitively-coupled contactless electrolyte-conductivity sensor.
Light-addressable potentiometric sensors (LAPS) consisting of a p-Si-SiO2 and p-Si-SiO2-Au structure, respectively, have been tested for a label-free electrical detection of DNA (deoxyribonucleic acid) hybridization. Three different strategies for immobilizing single-stranded probe DNA (ssDNA) molecules on a LAPS surface have been studied and compared: (a) immobilization of thiol-modified ssDNA on the patterned Au surface via gold-thiol bond, (b) covalent immobilization of amino-modified ssDNA onto the SiO2 surface functionalized with 3-aminopropyltriethoxysilane and (c) layer-by-layer adsorption of negatively charged ssDNA on a positively charged weak polyelectrolyte layer of poly(allylamine hydrochloride).
The chemical imaging sensor, which is based on the principle of the light-addressable potentiometric sensor (LAPS), is a powerful tool to visualize the spatial distribution of chemical species on the sensor surface. The spatial resolution of this sensor depends on the diffusion of photocarriers excited by a modulated light. In this study, a novel hybrid fiber-optic illumination was developed to enhance the spatial resolution. It consists of a modulated light probe to generate a photocurrent signal and a ring of constant light, which suppresses the lateral diffusion of minority carriers excited by the modulated light. It is demonstrated that the spatial resolution was improved from 92 μm to 68 μm.
Risk management for structures with a risk of explosion should be considered very carefully when performing a risk analysis according to IEC 62305-2. In contrast to the 2006 edition of the standard, the 2010 edition describes the topic “Structures with a risk of explosion” in more detail. Moreover, in Germany separate procedures and parameters are defined for the risk analysis of structures with a risk of explosion (Supplement 3 of the German DIN EN 62305-2 standard). This paper describes the contents and the relevant calculations of this Supplement 3, together with a numerical example.
The 2nd edition of the lightning risk management
standard (IEC 62305-2) considers structures, which may
endanger environment. In these cases, the loss is not limited to
the structure itself, which is valid for usual structures. In the past
(Edition 1) this danger was simply taken into account by a special
hazard factor, multiplying the existing risk for the structure with
a number. Now, in the edition 2, we add to the risk for the
structure itself a “second risk” due to the losses outside the
structure. The losses outside can be treated independently from
what occurs inside. This is a major advantage to analyze the risk
for sensitive structures, like chemical plants, nuclear plants, or
structures containing explosives, etc. In this paper, the existing
procedure given by the European version EN 62305-2 Ed.2 is
further developed and applied to a few structures.
This thesis introduces the Integrated Emitter Turn-Off (IETO) Thyristor as a new high-power device. Known state-of-the-art research activities like the Dual GCT, the ETO thyristor and the ICT were presented and critically reviewed. A comparison with commercialized solutions identifies the pros and cons of each type of device family. Based on this analysis, the IETO structure is proposed, covering most benefits of each device class. In particular the combination of a MOS-assisted turn-off with a thyristor-based device allows a voltage-controlled MOS switching and the low on-state voltage of the thyristors. The following synthesis of an IETO device stands on a three-dimensional field of optimization spanned by electric, mechanical and thermal aspects. From an electric point of view, the lowest possible parasitic inductance and resistance within the commutation path are optimization criteria. The mechanical construction has to withstand the required contact pressure of multiple kilo Newtons. Finally, thermal borders limit the maximum average current of the device. FEM simulations covering these three aspects are performed for several design proposals. An IETO prototype is constructed and measurements on various test benches attest thermal, mechanical and electric performance. A local decoupling of the external driver stage and the presspack housing is presented by a cable connection. This separation enables a thermal and mechanical independence, which is advantageous in terms of vibrations and thermal cycles including increased reliability. The electric pulse performance of the prototype device is a factor of 3.1 above today''s solutions. In single-pulse measurements, a current up to 1600 A was successfully turned off at 115°C with an active silicon area of 823 mm². One reason for this increased turn-off capability is the extremely low-inductive construction. Additional functionality of the IETO thyristor like over-current self-protection and defined short-circuit failure state are successfully verified.
Das von Texas-Instruments (TI) vertriebene Interface CBL2 wird über einige TI-Grafik-Rechner (TI-92, TI-89 usw.) angesteuert. Wegen seiner Handlichkeit wird dieses System beim Unterricht in wechselnden Räumen »großen« Messwerterfassungssystemen oft vorgezogen. Das CBL2 bietet drei analoge Eingänge, die immerhin mit 10 Bit Auflösung und bis zu einer Frequenz von 50 kHz arbeiten. Weiterhin besitzt das CBL2 eine Buchse für angeblich nur einen digitalen Ein- bzw. Ausgang. An diesem Eingang wird standardmäßig hauptsächlich der Bewegungssensor CBR betrieben. In diesem Beitrag werden Erweiterungsmöglichkeiten dieses Anschlusses beschrieben.
Wenn eine runde Platine mit LED-Zeile rotiert, entstehen leuchtende Ringe. Steuert man die LEDs mit einem Mikrocontroller an, lassen sich aber auch "stehende" Bilder darstellen. Unser elektronischer Kreisel kann Buchstaben und Ziffern anzeigen. Dabei wird das Erdmagnetfeld auf clevere Weise zur Synchronisation genutzt. Hier reichen die Anwendungen vom Rundenzähler bis zum Kompass!
Wir stellen einen USB-Baustein vor, der eine kostengünstige und universelle Möglichkeit schafft , im Unterricht den Themenkreis Messen-Steuern-Regeln zu behandeln. Die Funktionalität orientiert sich am CVK-Interface der Firma Fischertechnik. Im Gegensatz zu kommerziellen Lösungen erlaubt unser Aufbau auch den preiswerten Einsatz in Gruppen- oder Einzelarbeit. Abschließend berichten wir über ein Beispiel aus dem Unterrichtseinsatz.
This paper presents the latest prototype of the integrated emitter turn-off thyristor concept, which potentially ranks among thyristor high-power devices like the gate turn-off thyristor and the integrated gate-commutated thyristor (IGCT). Due to modifications of the external driver stage and mechanical press-pack design optimization, this prototype allows for full device characterization. The turn-off capability was increased to 1600 A with an active silicon area of 823mm2 . This leads to a transient peak power of 672.1kW/cm² . Within this paper, measurements and concept assessment are presented and a comparison to state-of-the-art IGCT devices is provided.