Article
Refine
Year of publication
- 2014 (142) (remove)
Document Type
- Article (142) (remove)
Keywords
- Antarctic Glaciology (1)
- DNA hybridization (1)
- Extraterrestrial Glaciology (1)
- Field-effect sensor (1)
- Glaciological instruments and methods (1)
- LAPS (1)
- Light-addressable Potentiometric Sensor (1)
- Subclacial exploration (1)
- Subglacial lakes (1)
- SunRav BookEditor (1)
- adsorption (1)
- barium strontium titanate (1)
- bioavailability (1)
- carbonized rice husk (1)
- contactless conductivity sensor (1)
- distance learning (1)
- drug metabolising enzymes (1)
- drug–drug interactions (1)
- e-books (1)
- e-issues (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (42)
- Fachbereich Chemie und Biotechnologie (25)
- INB - Institut für Nano- und Biotechnologien (25)
- Fachbereich Wirtschaftswissenschaften (19)
- Fachbereich Elektrotechnik und Informationstechnik (13)
- Fachbereich Maschinenbau und Mechatronik (13)
- Fachbereich Energietechnik (12)
- IfB - Institut für Bioengineering (12)
- Fachbereich Bauingenieurwesen (4)
- Fachbereich Luft- und Raumfahrttechnik (4)
- Fachbereich Architektur (3)
- Solar-Institut Jülich (3)
- Sonstiges (3)
- Institut fuer Angewandte Polymerchemie (1)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (1)
Feldbustechnologie
(2014)
Der Embedded Wireless-Report
(2014)
Generation Y
(2014)
A novel photoexcitation method for the light-addressable potentiometric sensor (LAPS) realized a higher spatial resolution of chemical imaging. In this method, a modulated light probe, which generates the alternating photocurrent signal, is surrounded by a ring of constant light, which suppresses the lateral diffusion of photocarriers by enhancing recombination. A device simulation verified that a higher spatial resolution could be obtained by adjusting the gap between the modulated and constant light. It was also found that a higher intensity and a longer wavelength of constant light was more effective. However, there exists a tradeoff between the spatial resolution and the amplitude of the photocurrent, and thus, the signal-to-noise ratio. A tilted incidence of constant light was applied, which could achieve even higher resolution with a smaller loss of photocurrent.
A semiconductor field-effect device has been used for an enzymatically catalyzed degradation of biopolymers for the first time. This novel technique is capable to monitor the degradation process of multiple samples in situ and in real-time. As model system, the degradation of the biopolymer poly(D, L-lactic acid) has been monitored in the degradation medium containing the enzyme lipase from Rhizomucor miehei. The obtained results demonstrate the potential of capacitive field-effect sensors for degradation studies of biodegradable polymers.
High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors for liquids. In this work, BST films have been applied as a sensitive transducer material for a label-free detection of adsorbed charged macromolecules (positively charged polyelectrolytes) and concentration of hydrogen peroxide vapor as well as protection insulator layer for a contactless electrolyte-conductivity sensor. The experimental results of characterization of individual sensors are presented. Special emphasis is devoted towards the development of a capacitively-coupled contactless electrolyte-conductivity sensor.