Article
Refine
Year of publication
Institute
- Fachbereich Bauingenieurwesen (327) (remove)
Has Fulltext
- no (327) (remove)
Document Type
- Article (327) (remove)
Keywords
- Architektur (2)
- Deutschland (2)
- Haustechnik (2)
- Heizung (2)
- Klimatechnik (2)
- Lüftung (2)
- Lüftungstechnik (2)
- Wasserbau (2)
- Wasserwirtschaft (2)
- Abluft (1)
- Anschlüsse an Stahlbeton (1)
- Brandfall (1)
- EN 1993-1-2 (1)
- Eingespannte Stützen und Träger (1)
- Einspanntiefen (1)
- Forschung, pränormativ (1)
- Hazard assessment (1)
- Landslide tsunamis (1)
- Large scale tests (1)
- Mischen (1)
- Nasskühlturm (1)
- Overland flow (1)
- PIV (1)
- Proper Orthogonal Decomposition (1)
- Q-criterion (1)
- Solitary waves (1)
- Stahlprofile (1)
- Tragwerksbemessung (1)
- Trockenkühlturm (1)
- VOF (1)
- anammox (1)
- coherent structures (1)
- dam-break (1)
- drag force (1)
- energy efficiency (1)
- hydraulic modelling (1)
- kombiniertes Verfahren (1)
- mainstream deammonification (1)
- model performance (1)
- nitrogen elimination (1)
- numerical model (1)
- physical model (1)
- steel profiles (1)
- structural design (1)
- wastewater (1)
Energy saving ordinances requires that buildings must be designed in such a way that the heat transfer surface including the joints is permanently air impermeable. The prefabricated roof and wall panels in lightweight steel constructions are airtight in the area of the steel covering layers. The sealing of the panel joints contributes to fulfil the comprehensive requirements for an airtight building envelope. To improve the airtightness of steel sandwich panels, additional sealing tapes can be installed in the panel joint. The influence of these sealing tapes was evaluated by measurements carried out by the RWTH Aachen University - Sustainable Metal Building Envelopes. Different installation situations were evaluated by carrying out airtightness tests for different joint distances. In addition, the influence on the heat transfer coefficient was also evaluated using the Finite Element Method (FEM). The combination of obtained air volume flow and transmission losses enables to create an "effective heat transfer coefficient" due to transmission and infiltration. This summarizes both effects in one value and is particularly helpful for approximate calculations on energy efficiency.
Im Herbst 2009 wurde das “Deutsche Gütesiegel Nachhaltiges Bauen” für die Gebäudetypen Industriebauten und Handelsbauten offiziell vorgestellt. Die Ökobilanz als wichtiger Baustein der Nachhaltigkeitsbewertung wird somit auch im Industrie- und Gewerbebau zukünftig stark an Bedeutung gewinnen.
Der vorliegende Beitrag beinhaltet einen Vergleich der Umweltleistung verschiedener Bauweisen des Industrie- und Gewerbebaus, die durch die Ökobilanzierung quantifizierbar wird, anhand von momentan verfügbaren Daten und Methoden. Es werden ausgewählte Ergebnisse sowie vorhandene Unsicherheiten und daraus resultierender Forschungsbedarf aufgezeigt.
Die Anforderungen an das energiesparende Bauen sind mit der Einführung der Energieeinsparverordnung (EnEV) 2009 auch im Industrie- und Gewerbebau deutlich verschärft worden. Einen wesentlichen Beitrag zur Energieeinsparung liefert die Minimierung des Transmissionswärmetransfers. Analysiert man Gebäudehüllen in Metallleichtbauweise stellt man fest, dass eine Erhöhung der Wärmedämmstärke allein noch nicht zielführend ist, zusätzlich sind Wärmebrückeneffekte zu berücksichtigen und deren Einflüsse auf die Wärmetransmission zu reduzieren. Neben der Bedeutung für die Energieeinsparung ist eine wärmetechnisch optimierte Detailausbildung auch erforderlich, um einen ausreichenden Feuchteschutz (Vermeidung von Tauwasser und Schimmelpilz) zu realisieren und so Schäden zu vermeiden. Ein wichtiges Hilfsmittel stellt hierzu der vom Industrieverband für Bausysteme im Metallleichtbau (IFBS) herausgegebene Wärmebrückenatlas der Metall-Sandwichbauweise dar.
Bauwirtschaft und Baurecht
(2006)
Beispiel Betoninstandsetzung
(2006)
Baustoffe
(2006)
Boden, Baugrube, Verbau
(2006)
Betoninstandsetzung
(2006)
Schalung und Gerüste
(2006)
Schalung und Gerüste
(2006)
As part of a novel approach to automatic sewer inspection, this paper presents a robust algorithm for automatic flow line detection. A large image repository is obtained from about 50,000 m sewers to represent the high variability of real world sewer systems. Automatic image processing combines Canny edge detection, Hough transform for straight lines and cost minimization using Dijkstra's shortest path algorithm. Assuming that flow lines are mostly smoothly connected horizontal structures, piecewise flow line delineation is reduced to a process of selecting adjacent line candidates. Costs are derived from the gap between adjacent candidates and their reliability. A single parameter α enables simple control of the algorithm. The detected flow line may precisely follow the segmented edges (α = 0.0) or minimize gaps at joints (α = 1.0). Both, manual and ground truth-based analysis indicate that α = 0.8 is optimal and independent of the sewer's material. The algorithm forms an essential step to further automation of sewer inspection.
Various models have been proposed for the prediction of the necessary support pressure at the face of a shallow tunnel. To assess their quality, the collapse of a tunnel face was modelled with small-scale model tests at single gravity. The development of the failure mechanism and the support force at the face in dry sand were investigated. The observed displacement patterns show a negligible influence of overburden on the extent and evolution of the failure zone. The latter is significantly influenced, though, by the initial density of the sand: in dense sand a chimney-wedge-type collapse mechanism developed, which propagated towards the soil surface. Initially, loose sand did not show any discrete collapse mechanism. The necessary support force was neither influenced by the overburden nor the initial density. A comparison with quantitative predictions by several theoretical models showed that the measured necessary support pressure is overestimated by most of the models. Those by Vermeer/Ruse and Léca/Dormieux showed the best agreement to the measurements.
Stützen und Träger aus Stahlprofilen können in Fundamente oder Wände aus Stahlbeton einbetoniert werden. Diese Anschlüsse wirken in der Regel wie Einspannungen, die eine ausreichende Einspanntiefe erfordern. Im Folgenden wird eine verallgemeinerte Berechnungsmethode für in Stahlbetonkonstruktionen eingespannte Stahlprofile aus gewalzten I-Profilen, geschweißten I-Profilen, runden Hohlprofilen, eckigen Hohlprofilen und einzelligen Kastenquerschnitten vorgestellt. Für Beanspruchungen infolge einachsiger Biegung um die starke und schwache Profilachse werden der profilabhängige Ansatz der Betondruckspannungen im Einspannbereich und die Ermittlung der Einspanntiefe behandelt. Unter Berücksichtigung der Normalkraft werden an den maßgebenden Stellen Tragfähigkeitsnachweise für die Stahlprofile geführt. Als Ergänzung zu den Berechnungsformeln werden Bemessungshilfen zur Verfügung gestellt, die die Wahl der mitwirkenden Breiten und der Einspanntiefen erleichtert.
Abfallentsorgung und Geruchsemissionen. Tl.2. Minderungsmaßnahmen / Frechen, F. B.; Kettern, J. T.
(1995)
Different analytical approaches exist to describe the structural substance or wear reserve of sewer systems. The aim is to convert engineering assessments of often complex defect patterns into computational algorithms and determine a substance class for a sewer section or manhole. This analytically determined information is essential for strategic rehabilitation planning processes up to network level, as it corresponds to the most appropriate rehabilitation type and can thus provide decision-making support. Current calculation methods differ clearly from each other in parts, so that substance classes determined by the different approaches are only partially comparable with each other. The objective of the German R&D cooperation project ‘SubKanS’ is to develop a methodology for classifying the specific defect patterns resulting from the interaction of all the individual defects, and their severities and locations. The methodology takes into account the structural substance of sewer sections and manholes, based on real data and theoretical considerations analogous to the condition classification of individual defects. The result is a catalogue of defect patterns and characteristics, as well as associated structural substance classifications of sewer systems (substance classes). The methodology for sewer system substance classification is developed so that the classification of individual defects can be transferred into a substance class of the sewer section or manhole, eventually taking into account further information (e.g. pipe material, nominal diameter, etc.). The result is a validated methodology for automated sewer system substance classification.