Article
Refine
Year of publication
- 2011 (178) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (65)
- INB - Institut für Nano- und Biotechnologien (36)
- Fachbereich Elektrotechnik und Informationstechnik (25)
- Fachbereich Chemie und Biotechnologie (22)
- Fachbereich Wirtschaftswissenschaften (19)
- IfB - Institut für Bioengineering (18)
- Fachbereich Energietechnik (13)
- Fachbereich Bauingenieurwesen (12)
- Fachbereich Maschinenbau und Mechatronik (10)
- Fachbereich Luft- und Raumfahrttechnik (9)
Has Fulltext
- no (178) (remove)
Document Type
- Article (178) (remove)
Keywords
- High field MRI (1)
- MR safety (1)
- MRI (1)
- Magneto alert sensor (1)
- Pornographie (1)
- Uktrahigh field MRI (1)
- Zuschauer (1)
- avalanche (1)
- snow (1)
Meiotic functions of RAD18
(2011)
The anticancer activity of titanium complexes has been known since the groundbreaking studies of Köpf and Köpf-Maier on titanocen dichloride. Unfortunately, possibly due to their fast hydrolysis, derivatives of titanocen dichloride failed in clinical studies. Recently, the new family of titanium salan complexes containing tetradentate ONNO ligands with anti-cancer properties has been discovered. These salan complexes are much more stabile in aqueous media. In this study we describe the biological activity of two titanium salan complexes in a mouse model of cervical cancer. High efficiency of this promising complex family was demonstrated for the first time in vivo. From these data we conclude that titanium salan complexes display very strong antitumor properties exhibiting only minor side effects. Our results may influence the chemotherapy with metallo therapeutics in the future.
One-chip integrated dual amperometric/field-effect sensor for the detection of dissolved hydrogen
(2011)
HisT/PLIER : A Two-Fold Provenance Approach for Grid-Enabled Scientific Workflows Using WS-VLAM
(2011)
Absatzkanäle kaum verknüpft
(2011)
The msprop program presented in this work is capable of solving the Maxwell–Schrödinger equations for one or several laser fields propagating through a medium of quantum optical few-level systems in one spatial dimension and in time. In particular, it allows to numerically treat systems in which a laser field interacts with the medium with both its electric and magnetic component at the same time. The internal dynamics of the few-level system is modeled by a quantum optical master equation which includes coherent processes due to optical transitions driven by the laser fields as well as incoherent processes due to decay and dephasing. The propagation dynamics of the laser fields is treated in slowly varying envelope approximation resulting in a first order wave equation for each laser field envelope function. The program employs an Adams predictor formula second order in time to integrate the quantum optical master equation and a Lax–Wendroff scheme second order in space and time to evolve the wave equations for the fields. The source function in the Lax–Wendroff scheme is specifically adapted to allow taking into account the simultaneous coupling of a laser field to the polarization and the magnetization of the medium. To reduce execution time, a customized data structure is implemented and explained. In three examples the features of the program are demonstrated and the treatment of a system with a phase-dependent cross coupling of the electric and magnetic field component of a laser field is shown.
Im Reich der Sinne
(2011)
The development and analysis of three waveguides for the exposure of small biological in vitro samples to mobile communication signals at 900 MHz (GSM, Global System for Mobile Communications), 1.8 GHz (GSM), and 2 GHz (UMTS, Universal Mobile Telecommunications System) is presented. The waveguides were based on a fin-line concept and the chamber containing the samples bathed in extracellular solution was placed onto two fins with a slot in between, where the exposure field concentrates. Measures were taken to allow for patch clamp recordings during radiofrequency (RF) exposure. The necessary power for the achievement of the maximum desired specific absorption rate (SAR) of 20 W/kg (average over the mass of the solution) was approximately Pin = 50 mW, Pin = 19 mW, and Pin = 18 mW for the 900 MHz, 1800 MHz, and 2 GHz devices, respectively. At 20 W/kg, a slight RF-induced temperature elevation in the solution of no more than 0.3 °C was detected, while no thermal offsets due to the electromagnetic exposure could be detected at the lower SAR settings (2, 0.2, and 0.02 W/kg). A deviation of 10% from the intended solution volume yielded a calculated SAR deviation of 8% from the desired value. A maximum ±10% variation in the local SAR could occur when the position of the patch clamp electrode was altered within the area where the cells to be investigated were located.
Purpose
To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T.
Materials and Methods
A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3.
Results
Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach.
Conclusion
A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.