Conference Proceeding
Refine
Year of publication
Institute
- Fachbereich Elektrotechnik und Informationstechnik (294)
- Fachbereich Energietechnik (230)
- Fachbereich Luft- und Raumfahrttechnik (204)
- Fachbereich Maschinenbau und Mechatronik (191)
- Solar-Institut Jülich (164)
- Fachbereich Medizintechnik und Technomathematik (162)
- IfB - Institut für Bioengineering (117)
- Fachbereich Bauingenieurwesen (103)
- ECSM European Center for Sustainable Mobility (62)
- Fachbereich Wirtschaftswissenschaften (57)
Has Fulltext
- no (1454) (remove)
Document Type
- Conference Proceeding (1454) (remove)
Keywords
- Enterprise Architecture (5)
- Gamification (5)
- Energy storage (4)
- IO-Link (4)
- Natural language processing (4)
- Power plants (4)
- hydrogen (4)
- solar sail (4)
- Associated liquids (3)
- Concentrated solar power (3)
Der Internally Commutated Thyristor (ICT) : ein neuartiger GCT mit integrierter Ausschalteinheit
(2007)
Selective Laser Melting (SLM) is one of the Additive Manufacturing (AM) technologies applicable for producing complex geometries which are typically expensive or difficult to fabricate using conventional methods. This process has been extensively investigated experimentally for various metals and the fabrication process parameters have been established for different applications; however, fabricating 3D glass objects using SLM technology has remained a challenge so far although it could have many applications. This paper presents a summery on various experimental evaluations of a material database incorporating the build parameters of glass powder using the SLM process for jewelry applications.
Heavy metal detection with semiconductor devices based on PLD-prepared chalcogenide glass thin films
(2007)
Risk management for structures with a risk of explosion should be considered very carefully when performing a risk analysis according to IEC 62305-2. In contrast to the 2006 edition of the standard, the 2010 edition describes the topic “Structures with a risk of explosion” in more detail. Moreover, in Germany separate procedures and parameters are defined for the risk analysis of structures with a risk of explosion (Supplement 3 of the German DIN EN 62305-2 standard). This paper describes the contents and the relevant calculations of this Supplement 3, together with a numerical example.
The 2nd edition of the lightning risk management
standard (IEC 62305-2) considers structures, which may
endanger environment. In these cases, the loss is not limited to
the structure itself, which is valid for usual structures. In the past
(Edition 1) this danger was simply taken into account by a special
hazard factor, multiplying the existing risk for the structure with
a number. Now, in the edition 2, we add to the risk for the
structure itself a “second risk” due to the losses outside the
structure. The losses outside can be treated independently from
what occurs inside. This is a major advantage to analyze the risk
for sensitive structures, like chemical plants, nuclear plants, or
structures containing explosives, etc. In this paper, the existing
procedure given by the European version EN 62305-2 Ed.2 is
further developed and applied to a few structures.