Conference Proceeding
Refine
Year of publication
- 2024 (16)
- 2023 (36)
- 2022 (47)
- 2021 (48)
- 2020 (46)
- 2019 (76)
- 2018 (65)
- 2017 (67)
- 2016 (66)
- 2015 (71)
- 2014 (52)
- 2013 (57)
- 2012 (59)
- 2011 (44)
- 2010 (68)
- 2009 (53)
- 2008 (37)
- 2007 (44)
- 2006 (61)
- 2005 (23)
- 2004 (22)
- 2003 (22)
- 2002 (25)
- 2001 (12)
- 2000 (12)
- 1999 (7)
- 1998 (8)
- 1997 (8)
- 1996 (4)
- 1995 (4)
- 1993 (6)
- 1992 (3)
- 1991 (2)
- 1990 (1)
- 1989 (3)
- 1988 (3)
- 1986 (1)
- 1985 (2)
- 1984 (3)
- 1983 (2)
- 1981 (2)
- 1980 (1)
- 1979 (1)
- 1978 (3)
- 1975 (2)
- 1973 (2)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (241)
- Fachbereich Medizintechnik und Technomathematik (218)
- Fachbereich Luft- und Raumfahrttechnik (189)
- Fachbereich Energietechnik (181)
- IfB - Institut für Bioengineering (151)
- Solar-Institut Jülich (110)
- Fachbereich Maschinenbau und Mechatronik (108)
- Fachbereich Bauingenieurwesen (75)
- Fachbereich Wirtschaftswissenschaften (57)
- ECSM European Center for Sustainable Mobility (53)
Language
- English (1197) (remove)
Document Type
- Conference Proceeding (1197) (remove)
Keywords
- Biosensor (25)
- CAD (7)
- Finite-Elemente-Methode (7)
- civil engineering (7)
- Bauingenieurwesen (6)
- Blitzschutz (6)
- Enterprise Architecture (5)
- Clusterion (4)
- Energy storage (4)
- Gamification (4)
Hydrostatic propeller drive
(2011)
Computational aeroelastic analysis and design of the HIRENASD wind tunnel wing model and tests
(2007)
Smart pixel : photonic mixer device (PMD) ; new system concept of a 3D-imaging camera-on-a-chip
(1998)
Time-of-flight (ToF) sensors have become an alternative to conventional distance sensing techniques like laser scanners or image based stereo. ToF sensors provide full range distance information at high frame-rates and thus have a significant impact onto current research in areas like online object recognition, collision prevention or scene reconstruction. However, ToF cameras like the photonic mixer device (PMD) still exhibit a number of challenges regarding static and dynamic effects, e.g. systematic distance errors and motion artefacts, respectively. Sensor calibration techniques reducing static system errors have been proposed and show promising results. However, current calibration techniques in general need a large set of reference data in order to determine the corresponding parameters for the calibration model. This paper introduces a new calibration approach which combines different demodulation techniques for the ToF- camera 's reference signal. Examples show, that the resulting combined demodulation technique yields improved distance values based on only two required reference data sets.
This article describes the functionality of a MATLAB® library that can be used to develop motion-logic applications in MATLAB programming language for industrial drive and control systems using the well known sercos automation bus. Therewith MATLAB's functionality is extended to designing automation applications from single axis machines up to multi-kinematic robots.
The determination of spacing, edge and end distance requirements for self-tapping screws requires numerous and comprehensive insertion tests. Yet the results of such tests cannot be transferred to other types of screws or even to screws of different diameter because of differences in shape or geometry. To reduce the effort of insertion tests a new method was developed which allows the estimation of required spacings, distances and timber thickness.
Effectiveness of the edge-based smoothed finite element method applied to soft biological tissues
(2012)
The interest in PET detectors with monolithic block scintillators is growing. In order to obtain high spatial resolutions dedicated positioning algorithms are required. But even an ideal algorithm can only deliver information which is provided by the detector. In this simulation study we investigated the light distribution on one surface of cuboid LSO scintillators of different size. Scintillators with a large aspect ratio (small footprint and large height) showed significant position information only for a minimum interaction depth of the gamma particle. The results allow a quantitative estimate for a useful aspect ratio.