Refine
Year of publication
- 2011 (329) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (82)
- Fachbereich Elektrotechnik und Informationstechnik (40)
- INB - Institut für Nano- und Biotechnologien (37)
- Fachbereich Wirtschaftswissenschaften (34)
- IfB - Institut für Bioengineering (34)
- Fachbereich Energietechnik (29)
- Fachbereich Chemie und Biotechnologie (28)
- Fachbereich Bauingenieurwesen (24)
- Fachbereich Maschinenbau und Mechatronik (24)
- Fachbereich Luft- und Raumfahrttechnik (23)
Document Type
- Article (182)
- Conference Proceeding (76)
- Book (24)
- Part of a Book (22)
- Report (7)
- Patent (5)
- Conference: Meeting Abstract (3)
- Other (3)
- Doctoral Thesis (2)
- Part of a Periodical (2)
Keywords
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (3)
- Aktionskunst (3)
- FH Aachen (2)
- Illustration (2)
- Interaktive Kunst (2)
- Kommunikationsguerrilla (2)
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- Stadtgestaltung (2)
The development and analysis of three waveguides for the exposure of small biological in vitro samples to mobile communication signals at 900 MHz (GSM, Global System for Mobile Communications), 1.8 GHz (GSM), and 2 GHz (UMTS, Universal Mobile Telecommunications System) is presented. The waveguides were based on a fin-line concept and the chamber containing the samples bathed in extracellular solution was placed onto two fins with a slot in between, where the exposure field concentrates. Measures were taken to allow for patch clamp recordings during radiofrequency (RF) exposure. The necessary power for the achievement of the maximum desired specific absorption rate (SAR) of 20 W/kg (average over the mass of the solution) was approximately Pin = 50 mW, Pin = 19 mW, and Pin = 18 mW for the 900 MHz, 1800 MHz, and 2 GHz devices, respectively. At 20 W/kg, a slight RF-induced temperature elevation in the solution of no more than 0.3 °C was detected, while no thermal offsets due to the electromagnetic exposure could be detected at the lower SAR settings (2, 0.2, and 0.02 W/kg). A deviation of 10% from the intended solution volume yielded a calculated SAR deviation of 8% from the desired value. A maximum ±10% variation in the local SAR could occur when the position of the patch clamp electrode was altered within the area where the cells to be investigated were located.
Objective
To investigate the feasibility of 7T MR imaging of the kidneys utilising a custom-built 8-channel transmit/receive radiofrequency body coil.
Methods
In vivo unenhanced MR was performed in 8 healthy volunteers on a 7T whole-body MR system. After B0 shimming the following sequences were obtained: 1) 2D and 3D spoiled gradient-echo sequences (FLASH, VIBE), 2) T1-weighted 2D in and opposed phase 3) True-FISP imaging and 4) a T2-weighted turbo spin echo (TSE) sequence. Visual evaluation of the overall image quality was performed by two radiologists.
Results
Renal MRI at 7T was feasible in all eight subjects. Best image quality was found using T1-weighted gradient echo MRI, providing high anatomical details and excellent conspicuity of the non-enhanced vasculature. With successful shimming, B1 signal voids could be effectively reduced and/or shifted out of the region of interest in most sequence types. However, T2-weighted TSE imaging remained challenging and strongly impaired because of signal heterogeneities in three volunteers.
Conclusion
The results demonstrate the feasibility and diagnostic potential of dedicated 7T renal imaging. Further optimisation of imaging sequences and dedicated RF coil concepts are expected to improve the acquisition quality and ultimately provide high clinical diagnostic value.
Das Ziel des Deutschen Corporate Governance Kodex (DCGK) besteht in der Verbesserung der Transparenz und Qualität der deutschen Corporate Governance, wobei die Sanktionierung der Nichteinhaltung des DCGK einzig durch etwaige Kapitalmarktreaktionen erfolgt. Folgende Befunde sprechen jedoch dafür, dass durch die Abgabe der Entsprechenserklärung gem. § 161 AktG die für das Enforcement des Kodex angenommene Selbstregulierung durch den Kapitalmarkt nicht stattfindet, und demnach Verbesserungsbedarf besteht
Anmerkung zu EuGH, Urt. v. 1.3.2011, Rs. C-236/09 Association belge des Consomma-teurs Test-Achats
(2011)
We present the novel concept of a combined drilling and melting probe for subsurface ice research. This probe, named “IceMole”, is currently developed, built, and tested at the FH Aachen University of Applied Sciences’ Astronautical Laboratory. Here, we describe its first prototype design and report the results of its field tests on the Swiss Morteratsch glacier. Although the IceMole design is currently adapted to terrestrial glaciers and ice shields, it may later be modified for the subsurface in-situ investigation of extraterrestrial ice, e.g., on Mars, Europa, and Enceladus. If life exists on those bodies, it may be present in the ice (as life can also be found in the deep ice of Earth).
Möglichkeiten und Grenzen der Anwendbarkeit statisch nichtlinearer Verfahren nach DIN EN 1998-1
(2011)
We present the novel concept of a combined drilling and melting probe for subsurface ice research. This probe, named “IceMole”, is currently developed, built, and tested at the FH Aachen University of Applied Sciences’ Astronautical Laboratory. Here, we describe its first prototype design and report the results of its field tests on the Swiss Morteratsch glacier. Although the IceMole design is currently adapted to terrestrial glaciers and ice shields, it may later be modified for the subsurface in-situ investigation of extraterrestrial ice, e.g., on Mars, Europa, and Enceladus. If life exists on those bodies, it may be present in the ice (as life can also be found in the deep ice of Earth).
Durch die Kombination von Oligonukleotid-Liganden (Aptameren) hoher Bindungsaffinitäten
mit hochselektiv abtrennbaren magnetisierbaren Mikropartikeln
wird eine einstufige Separation von Zielmolekülen aus mikrobiologischen
Produktionsansätzen möglich. Die Aptamere werden hierfür reversibel
auf den Partikeloberflächen gebunden und für die spezifische Isolierung von
Bioprodukten eingesetzt. Die Abtrennung der beladenen Partikel erfolgt
durch einen neuen Rotor-Stator-Separator mit Hochgradient-Magnetfeld.
Hydrostatic propeller drive
(2011)
Raum 02103 - eine Hommage
(2011)
Raum 02103. Ein Ort - tausende von Ideen, Geschichten und Träumen. die Bibliothek des Fachbereichs Design der FH Aachen. Eine scheinbar starre Gestalt und doch in ständigem Wandel. Menschen kommen und gehen; Dinge sind in Bewegung. Ein stiller Fluss von Veränderung, wie in einer eigenständigen Welt. Was macht diesen Ort aus? Was können Zahlen über ihn verraten? Und was befindet sich unter seiner strukturierten Oberfläche? Mit besonderem Blick auf das oft Unbemerkte, ist meine Arbeit eine Hommage an den „Raum 02103“ - an alles was ich dort bereits entdecken durfte und was noch zu entdecken ist.
Tests with palm tree leaves have just started yet and scan data are in the process to be analyzed. The final goal of future project for palm tree gender and species recognition will be to develop optical scanning technology to be applied to date palm tree leaves for in–situ screening purposes. Depending on the software used and the particular requirements of the users the technology potentially shall be able to identify palm tree diseases, palm tree gender, and species of young date palm trees by scanning leaves.
The demand of replacements for inoperable organs exceeds the amount of available organ transplants. Therefore, tissue engineering developed as a multidisciplinary field of research for autologous in-vitro organs. Such three dimensional tissue constructs request the application of a bioreactor. The UREPLACE bioreactor is used to grow cells on tubular collagen scaffolds OPTIMAIX Sponge 1 with a maximal length of 7 cm, in order to culture in vitro an adequate ureter replacement. With a rotating unit, (urothelial) cells can be placed homogeneously on the inner scaffold surface. Furthermore, a stimulation is combined with this bioreactor resulting in an orientation of muscle cells. These culturing methods request a precise control of several parameters and actuators. A combination of a LabBox and the suitable software LabVision is used to set and conduct parameters like rotation angles, velocities, pressures and other important cell culture values. The bioreactor was tested waterproof successfully. Furthermore, the temperature controlling was adjusted to 37 °C and the CO2 - concentration regulated to 5 %. Additionally, the pH step responses of several substances showed a perfect functioning of the designed flow chamber. All used software was tested and remained stable for several days.