Conference Proceeding
Refine
Year of publication
- 2024 (9)
- 2023 (35)
- 2022 (46)
- 2021 (48)
- 2020 (46)
- 2019 (74)
- 2018 (64)
- 2017 (66)
- 2016 (66)
- 2015 (71)
- 2014 (51)
- 2013 (57)
- 2012 (59)
- 2011 (44)
- 2010 (48)
- 2009 (53)
- 2008 (37)
- 2007 (44)
- 2006 (60)
- 2005 (23)
- 2004 (22)
- 2003 (22)
- 2002 (25)
- 2001 (12)
- 2000 (12)
- 1999 (7)
- 1998 (8)
- 1997 (8)
- 1996 (4)
- 1995 (4)
- 1993 (6)
- 1992 (3)
- 1991 (2)
- 1990 (1)
- 1989 (3)
- 1988 (3)
- 1986 (1)
- 1985 (2)
- 1984 (3)
- 1983 (2)
- 1981 (2)
- 1980 (1)
- 1979 (1)
- 1978 (3)
- 1975 (2)
- 1973 (2)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (234)
- Fachbereich Medizintechnik und Technomathematik (210)
- Fachbereich Luft- und Raumfahrttechnik (183)
- Fachbereich Energietechnik (177)
- IfB - Institut für Bioengineering (148)
- Solar-Institut Jülich (110)
- Fachbereich Maschinenbau und Mechatronik (107)
- Fachbereich Bauingenieurwesen (75)
- ECSM European Center for Sustainable Mobility (52)
- Fachbereich Wirtschaftswissenschaften (51)
Language
- English (1162) (remove)
Document Type
- Conference Proceeding (1162) (remove)
Keywords
- Biosensor (25)
- CAD (7)
- Finite-Elemente-Methode (7)
- civil engineering (7)
- Bauingenieurwesen (6)
- Blitzschutz (6)
- Enterprise Architecture (5)
- Clusterion (4)
- Energy storage (4)
- Gamification (4)
Leveraging Social Network Data for Analytical CRM Strategies - The Introduction of Social BI.
(2012)
Enceladus explorer - A maneuverable subsurface probe for autonomous navigation through deep ice
(2012)
Assessment of RF Safety of Transmit Coils at 7 Tesla by Experimental and Numerical Procedures (490.)
(2012)
The ”IceMole“ is a novel maneuverable subsurface ice probe for clean in-situ analysis and sampling of subsurface ice and subglacial water/brine. It is developed and build at FH Aachen University of Applied Sciences’ Astronautical Laboratory. A first prototype was successfully tested on the Swiss Morteratsch glacier in 2010. Clean sampling is achieved with a hollow ice screw (as it is used in mountaineering) at the tip of the probe. Maneuverability is achieved with a differentially heated melting head. Funded by the German Space Agency (DLR), a consortium led by FH Aachen currently develops a much more advanced IceMole probe, which includes a sophisticated system for obstacle avoidance, target detection, and navigation in the ice. We intend to use this probe for taking clean samples of subglacial brine at the Blood Falls (McMurdo Dry Valleys, East Antarctica) for chemical and microbiological analysis. In our conference contribution, we 1) describe the IceMole design, 2) report the results of the field tests of the first prototype on the Morteratsch glacier, 3) discuss the probe’s potential for the clean in-situ analysis and sampling of subsurface ice and subglacial liquids, and 4) outline the way ahead in the development of this technology.
Effectiveness of the edge-based smoothed finite element method applied to soft biological tissues
(2012)
Flight times to the heliopause using a combination of solar and radioisotope electric propulsion
(2011)
We investigate the interplanetary flight of a low-thrust space probe to the heliopause,located at a distance of about 200 AU from the Sun. Our goal was to reach this distance within the 25 years postulated by ESA for such a mission (which is less ambitious than the 15-year goal set by NASA). Contrary to solar sail concepts and combinations of allistic and electrically propelled flight legs, we have investigated whether the set flight time limit could also be kept with a combination of solar-electric propulsion and a second, RTG-powered upper stage. The used ion engine type was the RIT-22 for the first stage and the RIT-10 for the second stage. Trajectory optimization was carried out with the low-thrust optimization program InTrance, which implements the method of Evolutionary Neurocontrol,using Artificial Neural Networks for spacecraft steering and Evolutionary Algorithms to optimize the Neural Networks’ parameter set. Based on a parameter space study, in which the number of thrust units, the unit’s specific impulse, and the relative size of the solar power generator were varied, we have chosen one configuration as reference. The transfer time of this reference configuration was 29.6 years and the fastest one, which is technically
more challenging, still required 28.3 years. As all flight times of this parameter study were longer than 25 years, we further shortened the transfer time by applying a launcher-provided hyperbolic excess energy up to 49 km2/s2. The resulting minimal flight time for the reference configuration was then 27.8 years. The following, more precise optimization to a launch with the European Ariane 5 ECA rocket reduced the transfer time to 27.5 years. This is the fastest mission design of our study that is flexible enough to allow a launch every
year. The inclusion of a fly-by at Jupiter finally resulted in a flight time of 23.8 years,which is below the set transfer-time limit. However, compared to the 27.5-year transfer,this mission design has a significantly reduced launch window and mission flexibility if the
escape direction is restricted to the heliosphere’s “nose".