Refine
Year of publication
- 2004 (286) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (76)
- Fachbereich Elektrotechnik und Informationstechnik (35)
- INB - Institut für Nano- und Biotechnologien (35)
- Fachbereich Energietechnik (31)
- Fachbereich Wirtschaftswissenschaften (31)
- IfB - Institut für Bioengineering (26)
- Fachbereich Maschinenbau und Mechatronik (23)
- Fachbereich Luft- und Raumfahrttechnik (21)
- Fachbereich Bauingenieurwesen (20)
- Fachbereich Chemie und Biotechnologie (15)
Has Fulltext
- no (286) (remove)
Document Type
- Article (207)
- Book (35)
- Conference Proceeding (25)
- Part of a Book (5)
- Doctoral Thesis (4)
- Patent (4)
- Other (2)
- Contribution to a Periodical (1)
- Diploma Thesis (1)
- Report (1)
Keywords
- avalanche (1)
TOP-Energy : softwaregestützte Analyse und Optimierung industrieller Energieversorgungssysteme
(2004)
The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry.
Verfahren zur Bestimmung des enzymatischen Status humaner Haut in vitro [Offenlegungsschrift]
(2004)
This paper examines the positive and negative aspects of a range of interpretations of nearest-neighbours models. Measures-oriented and distributionoriented verification methods are applied to categorial, probabilistic and descriptive interpretations of nearest neighbours used operationally in avalanche forecasting in Scotland and Switzerland. The dependence of skill and accuracy measures on base rate is illustrated. The purpose of the forecast and the definition of events are important variables in determining the quality of the forecast. A discussion of the application of different interpretations in operational avalanche forecasting is presented.
Wasserwirtschaft
(2004)