Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1941) (remove)
Has Fulltext
- no (1941) (remove)
Document Type
- Article (1537)
- Conference Proceeding (162)
- Book (98)
- Part of a Book (63)
- Doctoral Thesis (28)
- Patent (17)
- Report (13)
- Other (8)
- Conference: Meeting Abstract (5)
- Habilitation (4)
Keywords
- Natural language processing (5)
- LAPS (4)
- CellDrum (3)
- Field-effect sensor (3)
- Light-addressable potentiometric sensor (3)
- Paired sample (3)
- hydrogen peroxide (3)
- impedance spectroscopy (3)
- Bacillus atrophaeus (2)
- Biocomposites (2)
On the Vanishing Displacement Current Limit for Eddy-Current Problems / Quell, P. ; Reißel, M.
(1996)
Über die Äquivalenz zweier Transmissionsrandwertprobleme aus der elektromagnetischen Streutheorie
(1994)
Magnetotomography and Electric Currents in a Fuel Cell / Lustfeld, H. ; Reißel, M. ; Steffen, B.
(2009)
A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack
(2010)
A novel scheme for detecting inhomogeneous internal currents in a fuel cell stack is presented. In this paper the scheme is investigated for the case that the flow field plates consist of graphite. Then plates of high conductivity, e.g. aluminium between the flow field plates together with small slits in these plates have three effects: (a) Whenever a local inhomogeneity of the electric current occurs at a particular cell in the stack, this will induce a surface current close to that cell perpendicular to the averaged current. This current can be detected. (b) The plates of high conductivity completely prevent the inhomogeneities from spreading to neighbouring cells. (c) Even at the particular cell the inhomogeneity is suppressed as far as possible. Thus this scheme leads to much better diagnostic possibilities and at the same time reduces electric instabilities to an extent, where they probably become harmless. This scheme will first be explained for a simple model to clarify the idea. However, very precise three dimensional computations using realistic parameters are presented, corroborating the results of the simple model.
A novel tomographic scheme for analysing the state of any single membrane electrode assembly (MEA) in a stack is suggested. Plates of very high conductivity placed between every fuel cell and slitted in an appropriate manner cause surface currents at well-defined locations of the stack. We show that knowing these surface currents, information about anomalies of the currents in a MEA can be obtained using the methods of tomography. The results are mathematically not unique. However, when assuming plausible defect structures, one can exclude improbable deficiencies by applying a special form of simulated annealing. We present numerical calculations of typical examples demonstrating that the essential defects of the MEA in any single cell of the stack can be detected and their extent can be determined.
Biomechanics studies biological soft tissue materials (growth, remodeling) in vivo. For this objective, the detailed information of material properties must be well defined to construct reliable constitutive models. In the paper, the bulge test is carried out with elastomers in order to develop a test method. Then, application of the test for soft tissue materials is straightforward due to the similarities between elastomers with soft tissue materials as proved in Holzapfel 2005, Ogden 2009. It means, after the preliminary experiments and parameter identification with rubber materials has been setup, experiments on soft tissue materials can be similarly carried out. Elastomers have a complex behavior which strongly depends on the largest previous load cycle. For simplicity we consider only the first loading.
Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method
(2010)
Bestimmung der metabolischen Aktivität von Mikroorganismen während des Biogasbildungsprozesses
(2009)
Capacitive field-effect electrolyte-diamond-insulator-semiconductor (EDIS) structures with O-terminated nanocrystalline diamond (NCD) as sensitive gate material have been realized and investigated for the detection of pH, penicillin concentration, and layer-by-layer adsorption of polyelectrolytes. The surface oxidizing procedure of NCD thin films as well as the seeding and NCD growth process on a Si-SiO2 substrate have been improved to provide high pH-sensitive, non-porous thin films without damage of the underlying SiO2 layer and with a high coverage of O-terminated sites. The NCD surface topography, roughness, and coverage of the surface groups have been characterized by SEM, AFM and XPS methods. The EDIS sensors with O-terminated NCD film treated in oxidizing boiling mixture for 45 min show a pH sensitivity of about 50 mV/pH. The pH-sensitive properties of the NCD have been used to develop an EDIS-based penicillin biosensor with high sensitivity (65-70 mV/decade in the concentration range of 0.25-2.5 mM penicillin G) and low detection limit (5 μM). The results of label-free electrical detection of layer-by-layer adsorption of charged polyelectrolytes are presented, too.
Urinary stone formation has been evolved to a widespread disease during the last years. The reason for the formation of urinary stones are little crystals, mostly composed of calcium oxalate, which are formed in human kidneys. The early diagnosis of the risk for urinary stone formation of patients can be determined by the “Bonn-Risk-Index” method based on the potentiometric detection of the Ca2+-ion concentration and an optical determination of the triggered crystallisation of calcium oxalate in unprocessed urine. In this work, miniaturised capacitive field-effect EMIS (electrolyte-membrane-insulator-semiconductor) sensors have been developed for the determination of the Ca2+-ion concentration in human native urine. The Ca2+-sensitive EMIS sensors have been systematically characterised by impedance spectroscopy, capacitance–voltage and constant–capacitance method in terms of sensitivity, signal stability and response time in both CaCl2 solutions and in native urine. The obtained results demonstrate the suitability of EMIS sensors for the measurement of the Ca2+-ion concentration in native urine of patients.
A handheld sensor system for the online measurement of hydrogen peroxide (H2O2) in aseptic sterilisation processes has been developed. It is based on a calorimetric-type gas sensor that consists of a differential set-up of two temperature sensors, of which one is catalytically activated and the second one is passivated and used as reference. The sensor principle relies in detecting a rise in temperature on the active sensor due to the exothermic reaction of H2O2 on the catalytic surface. To characterise the sensor system towards H2O2 sensitivity and other influencing factors, measurements have been carried out both at an experimental set-up and a manufacturer's sterilisation machine. Physical sensor characterisation was done by means of the optical microscopy.
The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of chemical species. For the practical application of this sensor, artifacts in the chemical images due to defects of the semiconductor substrate and contamination of the sensing surface etc. have been a major problem. An image correction method was developed to eliminate the influence of nonuniformity of individual sensor plate.
A novel strategy for enhanced field-effect biosensing using capacitive electrolyte–insulator–semiconductor (EIS) structures functionalised with pH-responsive weak polyelectrolyte/enzyme or dendrimer/enzyme multilayers is presented. The feasibility of the proposed approach is exemplarily demonstrated by realising a penicillin biosensor based on a capacitive p-Si–SiO2 EIS structure functionalised with a poly(allylamine hydrochloride) (PAH)/penicillinase and a poly(amidoamine) dendrimer/penicillinase multilayer. The developed sensors response to changes in both the local pH value near the gate surface and the charge of macromolecules induced via enzymatic reaction, resulting in a higher sensitivity. For comparison, an EIS penicillin biosensor with adsorptively immobilised penicillinase has been also studied. The highest penicillin sensitivity of 100 mV/dec has been observed for the EIS sensor functionalised with the PAH/penicillinase multilayer. The lower and upper detection limit was around 20 µM and 10 mM, respectively. In addition, an incorporation of enzymes in a multilayer prepared by layer-by-layer technique provides a larger amount of immobilised enzymes per sensor area, reduces enzyme leaching effects and thus, enhances the biosensor lifetime (the loss of penicillin sensitivity after 2 months was 10–12%).
Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection
(2010)
In aseptic filling systems, hydrogen peroxide vapour is commonly used for the reduction of microbial contaminations in carton packages. In this process, the germicidal efficiency of the vapour depends especially on the H₂O₂ concentration. To monitor the H₂O₂ concentration, a calorimetric H₂O₂ gas sensor based on a catalytically activated thin-film thermopile is investigated. Two different sensor layouts, namely a circular and a linear form, as well as two various material pairs such as tungsten/nickel and gold/nickel, have been examined for the realization of a thin-film thermopile. Additionally, manganese oxide and palladium particles have been compared as responsive catalysts towards H₂O₂. The thin-film sensors have been investigated at various H₂O₂ concentrations, gas temperatures and flow rates.
Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs
(2010)
In environmental analysis, cyanide and heavy metals play an important role, because these substances are highly toxic for biological systems. They can lead to chronic and acute diseases. Due to the chemical properties of cyanide it is frequently used for industrial processes such as extraction of silver and gold. Heavy metals can be found as trace elements in nature and are often applied in industries e.g., galvanization processes. Up to now, cyanide and heavy metals can be detected by several sensors separately and their detection is often limited to laboratory investigations. In this publication, with regard to an in situ analysis, a new miniaturized silicon-based sensor system for the simultaneous detection of cyanide and heavy metals in aqueous solutions is presented that is based on chalcogenide glass-based micro ion-selective electrodes (µISEs). The µISEs are incorporated into a specially designed measuring system for the simultaneous detection of heavy metals and cyanide in solutions and validated by simultaneous measurements of Cu2+- and CN−-ions, Cd2+- and CN−- ions and Pb2+- and CN−-ions. The particular sensor system has shown good sensor properties in the µ-molar ion-concentration range. For simultaneous measurements in complex heavy metal and cyanide solutions an intelligent software using fuzzy logic is discussed.