Refine
Year of publication
Institute
- INB - Institut für Nano- und Biotechnologien (557) (remove)
Language
- English (557) (remove)
Document Type
- Article (503)
- Conference Proceeding (39)
- Part of a Book (8)
- Doctoral Thesis (3)
- Book (2)
- Other (2)
Keywords
Handheld measurement device for field-effect sensor structures: Practical evaluation and limitations
(2007)
Optoelectronic Properties of Nanostructured Ensembles Controlled by Biomolecular Logic Systems
(2008)
Sensing charged macromolecules with nanocrystalline diamond-based field-effect capacitive sensors
(2008)
Microfabrication, characterization and analytical application of a new thin-film silver microsensor
(2009)
Layer-by-Layer Assembly of Carbon Nanotubes Incorporated in Light-Addressable Potentiometric Sensors
(2009)
Bacillus subtilis and Bacillus licheniformis are widely used for the large-scale industrial production of proteins. These strains can efficiently secrete proteins into the culture medium using the general secretion (Sec) pathway. A characteristic feature of all secreted proteins is their N-terminal signal peptides, which are recognized by the secretion machinery. Here, we have studied the production of an industrially important secreted protease, namely, subtilisin BPN′ from Bacillus amyloliquefaciens. One hundred seventy-three signal peptides originating from B. subtilis and 220 signal peptides from the B. licheniformis type strain were fused to this secretion target and expressed in B. subtilis, and the resulting library was analyzed by high-throughput screening for extracellular proteolytic activity. We have identified a number of signal peptides originating from both organisms which produced significantly increased yield of the secreted protease. Interestingly, we observed that levels of extracellular protease were improved not only in B. subtilis, which was used as the screening host, but also in two different B. licheniformis strains. To date, it is impossible to predict which signal peptide will result in better secretion and thus an improved yield of a given extracellular target protein. Our data show that screening a library consisting of homologous and heterologous signal peptides fused to a target protein can identify more-effective signal peptides, resulting in improved protein export not only in the original screening host but also in different production strains.
Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry
(2010)
A calorimetric gas sensor is presented for the monitoring of gas-phase H2O2 at elevated temperature during sterilization processes in aseptic food industry. The sensor consists of two temperature-sensitive thin-film resistances built up on a polyimide foil with a thickness of 25 μm, which are passivated with a layer of SU-8 photo resist and catalytically activated with manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilizes the elevated temperature of an evaporated H2O2 aerosol. In an experimental set-up, the sensor has shown a sensitivity of 4.78 °C/(%v/v) in a H2O2 concentration range of 0 to 10% v/v at an evaporation temperature of 240 ∘C. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied evaporation temperatures of the gas stream. The sensor characterization demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of sterilization processes.
Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach of read out in a light-addressable potentiometric sensor (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device which allows fast and flexible generation of light patterns. With the help of these light patterns the sensor surface of the LAPS device can be read out sequentially in a raster like scheme (scanning LAPS). The DLP approach has several advantages compared to conventional scanning LAPS set-ups, e.g., the spot size, the shape and the intensity of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of measurement.
The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the currentvoltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.
A new approach for a label-free electrical detection of DNA hybridization and denaturation using an array of individually addressable field-effect nanoplate SOI (silicon-on-insulator) capacitors functionalized with gold nanoparticles is presented. By using a constant-capacitance measuring setup in a differential mode, signal changes of ∼110 mV and ∼70 mV have been registered after the DNA hybridization and denaturation events, respectively.