Refine
Year of publication
- 2008 (157) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (53)
- IfB - Institut für Bioengineering (33)
- Fachbereich Elektrotechnik und Informationstechnik (27)
- Fachbereich Energietechnik (17)
- Fachbereich Luft- und Raumfahrttechnik (12)
- Fachbereich Wirtschaftswissenschaften (11)
- INB - Institut für Nano- und Biotechnologien (10)
- Fachbereich Chemie und Biotechnologie (9)
- Fachbereich Maschinenbau und Mechatronik (8)
- Solar-Institut Jülich (7)
Language
- English (157) (remove)
Document Type
- Article (103)
- Conference Proceeding (37)
- Book (7)
- Part of a Book (4)
- Doctoral Thesis (3)
- Lecture (1)
- Patent (1)
- Report (1)
Keywords
- Finite-Elemente-Methode (2)
- Limit analysis (2)
- Shakedown analysis (2)
- Telekommunikationsmarkt (2)
- Actuators (1)
- Aktor (1)
- Aktoren (1)
- First-order reliability method (1)
- Kohlenstofffaser (1)
- Lipopolysaccharide (1)
Due to the interfering effects of acetic acid in many fermentation processes, a gas-diffusion technique was developed for the online determination of acetic acid. The measurements were accomplished with a flow diffusion analysis (FDA) unit from the TRACE Analytics GmbH, Braunschweig, Germany. The diffusion analysis is based on the UV-absorbance of acetic acid at 205 nm. The measurement was achieved by the separation of an acceptor and a carrier stream (acidified fermentation broth) using a gas permeable polytetrafluoroethylene (PTFE) membrane, whereby broth constituents that would otherwise disturb the UV-measurement of acetic acid, are held back efficiently. Merely, the fermentation by-products, e.g. formic acid, is capable of diffusing through the membrane. While formic acid can disturb the measurement, carbon dioxide does not absorb at 205 nm. The method operates with time-dependent sample enrichment. During the analysis, a small volume of the acceptor stream is stopped for a defined time interval in the acceptor chamber. During this period, the gaseous acetic acid diffuses through the membrane and is enriched in the acceptor chamber. Subsequently after the enrichment, the acceptor stream flows through a UV-detector. The intensity of the signal is proportional to the acetic acid concentration. Online measurements in bioreactors via a sterile filtration probe have been accomplished. A linear calibration in the range of 0.5–5.0 g/L acetic acid with a relative standard deviation of <5 % was obtained. A sampling rate of 8 samples per hour was possible. The system was applied for the determination of acetic acid in E. coli fermentation broth. The instrument is easy to clean, very user-friendly and does not require any toxic or expensive reagents.
Investigation of TRPV1 loss-of-function phenotypes in transgenic shRNA expressing and knockout mice
(2008)
Tool supported requirements analysis for the user centered development of mobile enterprise software
(2008)
A user centered development method has proved satisfactory for the development of mobile enterprise software. To make use of this method, detailed information about the user and the place where the user interacts with his mobile device is required. This article describes how both can be modeled by a stereotypical and conceptual extended UML extension. Finally, a software tool is presented that supports the developed UML extension.
Optimization of the reaeration potential on embankment stepped spillways in skimming flow regime
(2008)
Solar tower power plants
(2008)
Enterprise SOA Roadmap
(2008)
Time-of-flight (ToF) sensors have become an alternative to conventional distance sensing techniques like laser scanners or image based stereo. ToF sensors provide full range distance information at high frame-rates and thus have a significant impact onto current research in areas like online object recognition, collision prevention or scene reconstruction. However, ToF cameras like the photonic mixer device (PMD) still exhibit a number of challenges regarding static and dynamic effects, e.g. systematic distance errors and motion artefacts, respectively. Sensor calibration techniques reducing static system errors have been proposed and show promising results. However, current calibration techniques in general need a large set of reference data in order to determine the corresponding parameters for the calibration model. This paper introduces a new calibration approach which combines different demodulation techniques for the ToF- camera 's reference signal. Examples show, that the resulting combined demodulation technique yields improved distance values based on only two required reference data sets.