Article
Refine
Year of publication
Institute
- Fachbereich Energietechnik (609) (remove)
Language
- English (361)
- German (246)
- Multiple languages (1)
- Dutch (1)
Document Type
- Article (609) (remove)
Keywords
- Earthquake (4)
- Blitzschutz (3)
- Lightning protection (2)
- lightning protection (2)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Alternative Energiequelle (1)
- Antibias (1)
- Artificial intelligence (1)
- BIM (1)
- Basisisolierung (1)
- Bauwerksüberwachung (1)
- Behaviour factor q (1)
- Bemessung (1)
- Biogas (1)
- Cardiovascular MRI (1)
- Circular bioeconomy (1)
- Civil engineering (1)
- DAC (1)
- DIN EN 1996 (1)
- Decoupling (1)
- Diversity Management (1)
- Dynamic simulation (1)
- Emilia-Romagna earthquake (1)
- Empirical consequence curves (1)
- Empirical fragility functions (1)
- Energietechnische Anlage (1)
- Engineering Habitus (1)
- Erdbebeneinwirkung (1)
- Fracture classification (1)
- Frame structure (1)
- Genetic algorithm (1)
- Germany (1)
- INODIS (1)
- INSYSME (1)
- Imaging (1)
- In-plane performance, isolation (1)
- Infill wall design (1)
- Left ventriular function (1)
- Linear elastic analysis (1)
- MR-stethoscope (1)
- Magnetic field strength (1)
- Magnetic resonance imaging (MRI) (1)
- Masonry infill (1)
- Masonry partition walls (1)
- Mauerwerksbauten (1)
- Mauerwerksgebäude (1)
- Methane (1)
- Modern constructions (1)
- Molten salt receiver system (1)
- Molten salt solar tower (1)
- Momentenverteilung (1)
- Monitoring (1)
- Monte Carlo Tree Search (1)
- Morphing (1)
- Multi-storey (1)
- Numerical modelling (1)
- Organizational Culture (1)
- Out-of-plane capacity (1)
- PBEE (1)
- Piping (1)
- Precast buildings (1)
- Probability distribution mapping (1)
- PushoverAnalysen (1)
- Rahmentragwirkung (1)
- Regenerative Energieanlagen (1)
- Reinforced concrete frame (1)
- Risikoabschätzung (1)
- Risikomanagement (1)
- Risk assessment (1)
- Risk management (1)
- Seismic design (1)
- Seismic loading (1)
- Sensor (1)
- Shoulder (1)
- Slab deflection (1)
- Structural design (1)
- Tank (1)
- Transient flux distribution (1)
- Two-phase modelling (1)
- Unreinforced masonry buildings (1)
- Verhaltensbeiwerte (1)
- Wand-Decken-Interaktion (1)
- arresters (1)
- atmospheric modeling (1)
- bio-methane (1)
- body limbs (1)
- bubble column (1)
- carbon dioxide removal (1)
- cardiac gating (1)
- cardiovascular MR imaging (1)
- change management (1)
- churches (1)
- climate neutrality (1)
- concentrating collector (1)
- conductors (1)
- deserts (1)
- direct air capture (1)
- distribution grid simulation (1)
- diversity management (1)
- e-mobility (1)
- earthquake engineering (1)
- economics (1)
- electrocardiogram (1)
- engineering (1)
- equivalent stiffness (1)
- granular silo (1)
- high field MR imaging (1)
- hypoplasticity (1)
- impulsive effects (1)
- in-plane behaviour (1)
- innovation management (1)
- lightning (1)
- liquid-storage tank (1)
- liquid-structure interaction (1)
- lizards (1)
- macro-element (1)
- magnetic resonance imaging (1)
- masonry infill (1)
- methanation (1)
- negative emissions (1)
- nonlinear transient analyses (1)
- out-of-plane behaviour (1)
- phonocardiogram (1)
- planning (1)
- plug flow reactor (1)
- point-focussing system (1)
- power generation (1)
- power transmission lines (1)
- power-to-gas (1)
- probability distribution (1)
- raytracing (1)
- renewable energy (1)
- research association (1)
- rollout (1)
- seismic (1)
- seismic response (1)
- smart-charging (1)
- solar process heat (1)
- standards (1)
- structure-soil-structure interaction (1)
- surges (1)
- swimming (1)
- truss (1)
- vault (1)
Damage of reinforced concrete (RC) frames with masonry infill walls has been observed after many earthquakes. Brittle behaviour of the masonry infills in combination with the ductile behaviour of the RC frames makes infill walls prone to damage during earthquakes. Interstory deformations lead to an interaction between the infill and the RC frame, which affects the structural response. The result of this interaction is significant damage to the infill wall and sometimes to the surrounding structural system too. In most design codes, infill walls are considered as non-structural elements and neglected in the design process, because taking into account the infills and considering the interaction between frame and infill in software packages can be complicated and impractical. A good way to avoid negative aspects arising from this behavior is to ensure no or low-interaction of the frame and infill wall, for instance by decoupling the infill from the frame. This paper presents the numerical study performed to investigate new connection system called INODIS (Innovative Decoupled Infill System) for decoupling infill walls from surrounding frame with the aim to postpone infill activation to high interstory drifts thus reducing infill/frame interaction and minimizing damage to both infills and frames. The experimental results are first used for calibration and validation of the numerical model, which is then employed for investigating the influence of the material parameters as well as infill’s and frame’s geometry on the in-plane behaviour of the infilled frames with the INODIS system. For all the investigated situations, simulation results show significant improvements in behaviour for decoupled infilled RC frames in comparison to the traditionally infilled frames.
Stahlbetonrahmentragwerke mit Ausfachungen aus Mauerwerk weisen nach Erdbeben häufig schwere Schäden auf. Gründe hierfür sind die Beanspruchungen der Ausfachungswände durch die aufgezwungenen Rahmenverformungen in Wandebene und die gleichzeitig auftretenden Trägheitskräfte senkrecht zur Wandebene in Kombination mit der konstruktiven Ausführung des Ausfachungsmauerwerks. Die Ausfachung wird in der Regel knirsch gegen die Rahmenstützen gemauert, wobei der Verschluss der oberen Fuge mit Mörtel oder Montageschaum erfolgt. Dadurch kommt es im Erdbebenfall zu lokalen Interaktionen zwischen Ausfachung und Rahmen, die in der Folge zu einem Versagen einzelner Ausfachungswände oder zu einem sukzessiven Versagen des Gesamtgebäudes führen können. Die beobachteten Schäden waren die Motivation dafür, in dem europäischen Forschungsprojekt INSYSME für Stahlbetonrahmentragwerke mit Ausfachungen aus hochwärmedämmenden Ziegelmauerwerk innovative Lösungen zur Verbesserung des seismischen Verhaltens zu entwickeln. Der vorliegende Beitrag stellt die im Rahmen des Projekts von den deutschen Projektpartnern (Universität Kassel, SDA-engineering GmbH) entwickelten Lösungen vor und vergleicht deren seismisches Verhalten mit der traditionellen Ausführung der Ausfachungswände. Grundlage für den Vergleich sind statisch-zyklische Wandversuche und Simulationen auf Wandebene. Aus den Ergebnissen werden Empfehlungen für die erdbebensichere Auslegung von Stahlbetonrahmentragwerken mit Ausfachungen aus Ziegelmauerwerk abgeleitet.
Because of simple construction process, high energy efficiency, significant fire resistance and excellent sound isolation, masonry infilled reinforced concrete (RC) frame structures are very popular in most of the countries in the world, as well as in seismic active areas. However, many RC frame structures with masonry infills were seriously damaged during earthquake events, as the traditional infills are generally constructed with direct contact to the RC frame which brings undesirable infill/frame interaction. This interaction leads to the activation of the equivalent diagonal strut in the infill panel, due to the RC frame deformation, and combined with seismically induced loads perpendicular to the infill panel often causes total collapses of the masonry infills and heavy damages to the RC frames. This fact was the motivation for developing different approaches for improving the behaviour of masonry infills, where infill isolation (decoupling) from the frame has been more intensively studied in the last decade. In-plane isolation of the infill wall reduces infill activation, but causes the need for additional measures to restrain out-of-plane movements. This can be provided by installing steel anchors, as proposed by some researchers. Within the framework of European research project INSYSME (Innovative Systems for Earthquake Resistant Masonry Enclosures in Reinforced Concrete Buildings) the system based on a use of elastomers for in-plane decoupling and steel anchors for out-of-plane restrain was tested. This constructive solution was tested and deeply investigated during the experimental campaign where traditional and decoupled masonry infilled RC frames with anchors were subjected to separate and combined in-plane and out-of-plane loading. Based on a detailed evaluation and comparison of the test results, the performance and effectiveness of the developed system are illustrated.
Armiranobetonske (AB) zgrade sa zidanom ispunom
se izvode u mnogim zemljama širom sveta. Iako se
zidana ispuna posmatra kao nekonstruktivni element, ona
značajno utiče na promenu dinamičkih karakteristika AB
ramovskih konstrukcija u toku zemljotresnog dejstva.
Odskora, značajan napor je utrošen na istraživanje
izolovanih ispuna, koje su odvojene od okolnog rama
obično ostavljanjem prostora između rama i ispune. U
ovom slučaju deformacija rama ne aktivira ispunu i na taj
način ispuna ne utiče na ponašanje rama. Ovaj rad
predstavlja rezultate istraživanja ponašanja AB
ramovskih zgrada sa INODIS sistemom koji izoluje ispunu
u odnosu na okolni ram. Uticaj izolovane ispune je prvo
ispitan na jednospratnim i jednobrodnim ramovima. Ovo
je iskorišćeno kao osnova za parametarsku analizu na
višespratnim i višebrodnim ramovima, kao i na primeru
zgrade. Promena krutosti i dinamičkih karakteristika je
analizirano kao i odgovor pri zemljotresnom dejstvu.
Izvršeno je poređenje sa praznom ramovskom
konstrukcijom kao i ramovima ispunjenim ispunom na
tradicionalni način. Rezultati pokazuju da je ponašanje
ramova sa izolovanom ispunom slično ponašanju praznih
ramova, dok je ponašanje ramova sa tradicionalnom
ispunom daleko drugačije i zahteva kompleksne
numeričke modele. Ovo znači da ukoliko se primeni
adekvatna konstruktivna mera izolacije ispune, proračun
ramovskim zgrada sa zidanom ispunom se može
značajno pojednostaviti.
This study analyses the expected utilization of an urban distribution grid under high penetration of photovoltaic and e-mobility with charging infrastructure on a residential level. The grid utilization and the corresponding power flow are evaluated, while varying the control strategies and photovoltaic installed capacity in different scenarios. Four scenarios are used to analyze the impact of e-mobility. The individual mobility demand is modelled based on the largest German studies on mobility “Mobilität in Deutschland”, which is carried out every 5 years. To estimate the ramp-up of photovoltaic generation, a potential analysis of the roof surfaces in the supply area is carried out via an evaluation of an open solar potential study. The photovoltaic feed-in time series is derived individually for each installed system in a resolution of 15 min. The residential consumption is estimated using historical smart meter data, which are collected in London between 2012 and 2014. For a realistic charging demand, each residential household decides daily on the state of charge if their vehicle requires to be charged. The resulting charging time series depends on the underlying behavior scenario. Market prices and mobility demand are therefore used as scenario input parameters for a utility function based on the current state of charge to model individual behavior. The aggregated electricity demand is the starting point of the power flow calculation. The evaluation is carried out for an urban region with approximately 3100 residents. The analysis shows that increased penetration of photovoltaics combined with a flexible and adaptive charging strategy can maximize PV usage and reduce the need for congestion-related intervention by the grid operator by reducing the amount of kWh charged from the grid by 30% which reduces the average price of a charged kWh by 35% to 14 ct/kWh from 21.8 ct/kWh without PV optimization. The resulting grid congestions are managed by implementing an intelligent price or control signal. The analysis took place using data from a real German grid with 10 subgrids. The entire software can be adapted for the analysis of different distribution grids and is publicly available as an open-source software library on GitHub.
Non-nuclear and non-fossil energy resources and their possibilities for future power generation
(1975)
It must be stressed that the assessment of the exploitation possibilities of the energy resources discussed in this paper requires further studies. With this proviso, the situation can be provisionally summarised as follows: The total potential of known geothermal steam sources is only 64 GW. Geothermal energy could therefore only make a significant contribution to covering the worldwide power needs if we succeed in exploiting dry geothermal reservoirs. Exploitation of tidal energy is limited to a few geographically favourable locations. The power generation potential at these locations is only about 64 GW. An important drawback of tidal power is discontinuous power generation. Large scale exploitation of wind, wave and glacier energy, and of ocean heat, requires solution of a number of technological problems. The environmental effects of exploitation of these energy resources are to some extent of a qualitatively different nature from those of operation of fossil-fuel-fired and of nuclear power plants. The scanty knowledge in this area often results in these effects being underestimated. In any case, however, it would be deliberately misleading to postulate that any form of power generation is possible without some detrimental effects on the environment. It may be stated in conclusion that, owing to their small potential or to the as yet insufficiently advanced technological development, none of the energy resources discussed in this paper can make a significant contribution to the solution of middle-term energy supply problems, i.e., to a rapid replacement of mineral oil and natural gas.
EU-Projekt INSYSME : innovative Systeme für erdbebentaugliche Ausfachungswände aus Ziegelmauerwerk
(2014)
In recent years, many onshore wind turbines are erected in seismic active regions and on soils with poor load bearing capacity, where pile grids are inevitable to transfer the loads into the ground. In this contribution, a realistic multi pile grid is designed to analyze the dynamics of a wind turbine tower including frequency dependent soil-structure-interaction. It turns out that different foundations on varying soil configurations heavily influence the vibration response. While the vibration amplitude is mostly attenuated, certain unfavorable combinations of structure and soil parameters lead to amplification in the range of the system's natural frequencies. This testifies the need for overall dynamic analysis in the assessment of the dynamic stability and the holistic frequency tuning of the turbines.
Verformungsbasierter seismischer Nachweis von Mauerwerksbauten mit der Kapazitätsspektrum-Methode
(2005)
Recent earthquakes as the 2012 Emilia earthquake sequence showed that recently built unreinforced masonry (URM) buildings behaved much better than expected and sustained, despite the maximum PGA values ranged between 0.20–0.30 g, either minor damage or structural damage that is deemed repairable. Especially low-rise residential and commercial masonry buildings with a code-conforming seismic design and detailing behaved in general very well without substantial damages. The low damage grades of modern masonry buildings that was observed during this earthquake series highlighted again that codified design procedures based on linear analysis can be rather conservative. Although advances in simulation tools make nonlinear calculation methods more readily accessible to designers, linear analyses will still be the standard design method for years to come. The present paper aims to improve the linear seismic design method by providing a proper definition of the q-factor of URM buildings. These q-factors are derived for low-rise URM buildings with rigid diaphragms which represent recent construction practise in low to moderate seismic areas of Italy and Germany. The behaviour factor components for deformation and energy dissipation capacity and for overstrength due to the redistribution of forces are derived by means of pushover analyses. Furthermore, considerations on the behaviour factor component due to other sources of overstrength in masonry buildings are presented. As a result of the investigations, rationally based values of the behaviour factor q to be used in linear analyses in the range of 2.0–3.0 are proposed.
The proposed Den Haag Zuidwest district heating system of the city of The Hague consists of a deep doublet in a Jurassic sandstone layer that is designed for a production temperature of 75 °C and a reinjection temperature of 40 °C at a flow rate of 150 m3 h−1. The prediction of reservoir temperature and production behavior is crucial for success of the proposed geothermal doublet. This work presents the results of a study of the important geothermal and geohydrological issues for the doublet design. In the first phase of the study, the influences of the three-dimensional (3D) structures of anticlines and synclines on the temperature field were examined. A comprehensive petrophysical investigation was performed to build a large scale 3D-model of the reservoir. Several bottomhole temperatures (BHTs), as well as petrophysical logs were used to calibrate the model using thermal conductivity measurements on 50 samples from boreholes in different lithological units in the study area. Profiles and cross sections extracted from the calculated temperature field were used to study the temperature in the surrounding areas of the planned doublet. In the second phase of the project, a detailed 3D numerical reservoir model was set up, with the aim of predicting the evolution of the producer and injector temperatures, and the extent of the cooled area around the injector. The temperature model from the first phase provided the boundary conditions for the reservoir model. Hydraulic parameters for the target horizons, such as porosity and permeability, were taken from data available from the nearby exploration wells. The simulation results are encouraging as no significant thermal breakthrough is predicted. For the originally planned location of the producer, the extracted water temperature is predicted to be around 79 °C, with an almost negligible cooling in the first 50 years of production. When the producer is located shallower parts of the reservoir, the yield water temperatures is lower, starting at ≈76 °C and decreasing to ≈74 °C after 50 years of operation. This comparatively larger decrease in temperature with time is caused by the structural feature of the reservoir, namely a higher dip causes the cooler water to easily move downward. In view of the poor reservoir data, the reservoir simulation model is constructed to allow iterative updates using data assimilation during planned drilling, testing, and production phases. Measurements during an 8 h pumping test carried out in late 2010 suggest that a flow rate of 150 m3 h−1 is achievable. Fluid temperatures of 76.5 °C were measured, which is very close to the predicted value.
A refined substructure technique in the frequency domain is developed, which permits consideration of the interaction effects among adjacent containers through the supporting deformable soil medium. The tank-liquid systems are represented by means of mechanical models, whereas discrete springs and dashpots stand for the soil beneath the foundations. The proposed model is employed to assess the responses of adjacent circular, cylindrical tanks for harmonic and seismic excitations over wide range of tank proportions and soil conditions. The influence of the number, spatial arrangement of the containers and their distance on the overall system's behavior is addressed. The results indicate that the cross-interaction effects can substantially alter the impulsive components of response of each individual element in a tank farm. The degree of this impact is primarily controlled by the tank proportions and the proximity of the predominant natural frequencies of the shell-liquid-soil systems and the input seismic motion. The group effects should be not a priori disregarded, unless the tanks are founded on shallow soil deposit overlying very stiff material or bedrock.
The fundamental modeling of energy systems through individual unit commitment decisions is crucial for energy system planning. However, current large-scale models are not capable of including uncertainties or even risk-averse behavior arising from forecasting errors of variable renewable energies. However, risks associated with uncertain forecasting errors have become increasingly relevant within the process of decarbonization. The intraday market serves to compensate for these forecasting errors. Thus, the uncertainty of forecasting errors results in uncertain intraday prices and quantities. Therefore, this paper proposes a two-stage risk-constrained stochastic optimization approach to fundamentally model unit commitment decisions facing an uncertain intraday market. By the nesting of Lagrangian relaxation and an extended Benders decomposition, this model can be applied to large-scale, e.g., pan-European, power systems. The approach is applied to scenarios for 2023—considering a full nuclear phase-out in Germany—and 2035—considering a full coal phase-out in Germany. First, the influence of the risk factors is evaluated. Furthermore, an evaluation of the market prices shows an increase in price levels as well as an increasing day-ahead-intraday spread in 2023 and in 2035. Finally, it is shown that intraday cross-border trading has a significant influence on trading volumes and prices and ensures a more efficient allocation of resources.
Möglichkeiten und Grenzen der Anwendbarkeit statisch nichtlinearer Verfahren nach DIN EN 1998-1
(2011)