Refine
Year of publication
- 2006 (330) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (75)
- Fachbereich Bauingenieurwesen (51)
- Fachbereich Wirtschaftswissenschaften (45)
- Fachbereich Luft- und Raumfahrttechnik (32)
- Fachbereich Energietechnik (29)
- Fachbereich Maschinenbau und Mechatronik (29)
- Fachbereich Elektrotechnik und Informationstechnik (27)
- IfB - Institut für Bioengineering (24)
- INB - Institut für Nano- und Biotechnologien (22)
- Fachbereich Chemie und Biotechnologie (17)
Language
- German (166)
- English (160)
- Russian (2)
- Portuguese (1)
- Spanish (1)
Document Type
- Article (180)
- Conference Proceeding (94)
- Book (29)
- Patent (6)
- Part of a Book (5)
- Diploma Thesis (3)
- Lecture (3)
- Other (3)
- Course Material (2)
- Report (2)
Keywords
- Biosensor (23)
- CAD (3)
- Technische Mechanik (3)
- Bauingenieurwesen (2)
- Bauplanung (2)
- Führung (2)
- Leadership (2)
- Motivation (2)
- Rapid Prototyping (2)
- Rapid prototyping (2)
Hands-on-training in high technology areas is usually limited due to the high cost for lab infrastructure and equipment. One specific example is the field of MEMS, where investment and upkeep of clean rooms with microtechnology equipment is either financed by production or R&D projects greatly reducing the availability for education purposes. For efficient hands-on-courses a MEMS training foundry, currently used jointly by six higher education institutions, was established at FH Kaiserslautern. In a typical one week course, students manufacture a micromachined pressure sensor including all lithography, thin film and packaging steps. This compact and yet complete program is only possible because participants learn to use the different complex machines in advance via a Virtual Training Lab (VTL). In this paper we present the concept of the MEMS training foundry and the VTL preparation together with results from a scientific evaluation of the VTL over the last three years.
Quartz crystal nanobalance (QCN) sensors are considered as powerful masssensitive sensors to determine materials in the sub-nanogram level. In this study, a single piezoelectric quartz crystal nanobalance modified with polystyrene was employed to detect benzene, toluene, ethylbenzene and xylene (BTEX compounds). The frequency shift of the QCN sensor was found to be linear against the BTEX compound concentrations in the range about 1-45 mg l-1. The correlation coefficients for benzene, toluene, ethylbenzene, and xylene were 0.991, 0.9977, 0.9946 and 0.9971, respectively. The principal component analysis was also utilized to process the frequency response data of the single piezoelectric crystal at different times, considering to the different adsorption-desorption dynamics of BTEX compounds. Using principal component analysis, it was found that over 90% of the data variance could still be explained by use of two principal components (PC1 and PC2). Subsequently, the successful identification of benzene and toluene was possible through the principal component analysis of the transient responses of the polystyrene modified QCN sensor. The results showed that the polystyrene-modified QCN had favorable identification and quantification performances for the BTEX compounds.
Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator
(2006)
This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis.
Strategien zur Zustandserfassung von Kanalisationen. Aachener Schriften zur Stadtentwässerung. Bd 7
(2006)
Bauhaus Europa: Die Genese
(2006)
An H2O2 sensor for the application in industrial sterilisation processes has been developed. Therefore, automated sterilisation equipment at laboratory scale has been constructed using parts from industrial sterilisation facilities. In addition, a software tool has been developed for the control of the sterilisation equipment at laboratory scale. First measurements with the developed sensor set-up as part of the sterilisation equipment have been performed and the sensor has been physically characterised by optical microscopy and SEM.
Unfallverhütung
(2006)
Kalkulation
(2006)
In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD+, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results obtained by the spectrophotometric method were compared with the results obtained by the colourimetry, using pH indicators. The above-mentioned two methods will be used as references for potentiometric measurements of phenylalanine concentration.
In this paper, methods of surface modification of different supports, i.e. glass and polymeric beads for enzyme immobilisation are described. The developed method of enzyme immobilisation is based on Schiff’s base formation between the amino groups on the enzyme surface and the aldehyde groups on the chemically modified surface of the supports. The surface of silicon modified by APTS and GOPS with immobilised enzyme was characterised by atomic force microscopy (AFM), time-of-flight secondary ion mass spectroscopy (ToF-SIMS) and infrared spectroscopy (FTIR). The supports with immobilised enzyme (urease) were also tested in combination with microreactors fabricated in silicon and Perspex, operating in a flow-through system. For microreactors filled with urease immobilised on glass beads (Sigma) and on polymeric beads (PAN), a very high and stable signal (pH change) was obtained. The developed method of urease immobilisation can be stated to be very effective.
Die Erfindung betrifft einen elektromagnetischen Aktuator zur Betätigung eines Stellgliedes (7) mit wenigstens einem gesteuert bestrombaren Elektromagneten (1, 2) und einem mit dem Stellglied (7) in Wirkverbindung stehenden Anker (5), der bei Bestromung des Elektromagneten (1, 2) gegen die Kraft wenigstens einer an einem Gehäuse (12) abgestützten Rückstellfeder (10) an der Polfläche (3, 4) des Elektromagneten (1, 2) zur Anlage kommt, und daß zumindest der Anker (5) über eine sphärische Gelenkanordnung (11) auf der Rückstellfeder (10) abgestützt ist.
A new and simple method for nanostructuring using conventional photolithography and layer expansion or pattern-size reduction technique is presented, which can further be applied for the fabrication of different nanostructures and nano-devices. The method is based on the conversion of a photolithographically patterned metal layer to a metal-oxide mask with improved pattern-size resolution using thermal oxidation. With this technique, the pattern size can be scaled down to several nanometer dimensions. The proposed method is experimentally demonstrated by preparing nanostructures with different configurations and layouts, like circles, rectangles, trapezoids, “fluidic-channel”-, “cantilever”- and meander-type structures.