Refine
Year of publication
Institute
- Solar-Institut Jülich (335) (remove)
Has Fulltext
- no (335) (remove)
Document Type
- Conference Proceeding (164)
- Article (105)
- Part of a Book (24)
- Report (20)
- Book (17)
- Doctoral Thesis (3)
- Contribution to a Periodical (2)
Keywords
The Lehrstuhl für Wärmeübertragung und Klimatechnik at the Aachen University of Technology operates several test facilities to investigate fundamentals of heat and mass transfer supported by the Deutsche Forschungsgemeinschaft, the Minister für Forschung und Technologie and the industry. In order to get high-resolution and reproselection of hardware components is as critical as the design of software routines to perform successful and accurate measurements. In the following the development of the measurement and control system for three different test facilities is presented and discussed. Special attention is given to the education of students within the framework of laboratories and scientific experiments.
Die bei Kohlekraftwerksprozessen entstehenden Rauchgase enthalten einen nicht unerheblichen Teil an Schadgaskomponenten (z.B. Stickoxide), die aus dem Gasstrom entfernt werden müssen. Im Rahmen von Forschungsvorhaben des BMBF und verschiedener Industriepartner betreibt der Lehrstuhl für Wärmeübertragung und Klimatechnik der RWTH Aachen Pilotanlagen und Prüfstände für Untersuchungen auf dem Gebiet der homogenen und heterogen-katalytischen Schadstoffreduktion heißer Rauchgase bei Temperaturen bis zu 900 °C. Für die Erforschung der Minderungspotentiale geeigneter, auf Distickstoffoxid reduzierend wirkender Additive, wie Wasserstoffperoxid, oder auch Katalysatoren, befindet sich ein Reaktor in Betrieb, der eine Untersuchung der Reaktionskinetik bei der Entfernung von Schadgaskomponenten aus einem lnertgasstrom ermöglicht. Wesentlich für den Erfolg der Forschungsarbeit ist eine auf das spezielle Projekt genau abgestimmte Meß- und Regelungstechnik. Neben der Auswahl geeigneter Hardwarekomponenten ist auch die Softwareentwicklung unter einer leistungsstarken und zuverlässigen Programmierumgebung von großer Bedeutung. Hierbei dient die unter LabVIEW 5.01 entwickelte Datenerfassung- und Auswertesoftware zum einen der Messung, Visualisierung und Regelung der relevanten Temperaturen, Drücke, Konzentrationen und Volumenströme einzelner Gaskomponenten. Zum anderen ermöglicht sie parallel eine numerische Simulation der Vorgänge innerhalb des Reaktors zur Anpassung reaktionskinetischer Parameter aus den sich ergebenden Versuchsdaten durch Lösung eindimensionaler, stationärer Erhaltungsgleichungen.
Eldorado summer schools
(1994)
The optical performance of a 2-axis solar concentrator was simulated with the COMSOL Multiphysics® software. The concentrator consists of a mirror array, which was created using the application builder. The mirror facets are preconfigured to form a focal point. During tracking all mirrors are moved simultaneously in a coupled mode by 2 motors in two axes, in order to keep the system in focus with the moving sun. Optical errors on each reflecting surface were implemented in combination with the solar angular cone of ± 4.65 mrad. As a result, the intercept factor of solar radiation that is available to the receiver was calculated as a function of the transversal and longitudinal angles of incidence. In addition, the intensity distribution on the receiver plane was calculated as a function of the incidence angles.
Simulationsprogramme in der Solarenergie-Ausbildung / Blum, K. ; Göttsche, J. ; Schumacher, J.
(1994)
Analyse der Studentenwohnungen des Solar-Campus Jülich / Göttsche, Joachim ; Gabrysch, Karten
(2001)
The cost of solar tower power plants is dominated by the heliostat field making up roughly 50% of investment costs. Classical heliostat design is dominated by mirrors brought into position by steel structures and drives that guarantee high accuracies under wind loads and thermal stress situations. A large fraction of costs is caused by the stiffness requirements of the steel structure, typically resulting in ~ 20 kg/m² steel per mirror area. The typical cost figure of heliostats (figure mentioned by Solucar at Solar Paces Conference, Seville, 2006) is currently in the area of 150 €/m² caused by the increasing price of the necessary raw materials. An interesting option to reduce costs lies in a heliostat design where all moving parts are protected from wind loads. In this way, drives and mechanical layout may be kept less robust, thereby reducing material input and costs. In order to keep the heliostat at an appropriate size, small mirrors (around 10x10 cm²) have to be used, which are placed in a box with a transparent cover. Innovative drive systems are developed in order to obtain a cost-effective design. A 0,5x0,5 m² demonstration unit will be constructed. Tests of the unit are carried out with a high-precision artificial sun unit that imitates the sun’s path with an accuracy of less than 0.5 mrad and creates a beam of parallel light with a divergence of less than 4 mrad.
Advanced window systems and building energy performance / S. Reilly ; J. Göttsche ; V. Wittwer
(1991)
LACASA - ein Instrument zur energetischen Analyse und Optimierung von Gebäuden mit Anlagentechnik
(2004)
This chapter introduces performance and acceptance testing and describes state-of-the-art tools, methods, and instruments to assess the plant performance or realize plant acceptance testing. The status of the development of standards for performance assessment is given.