Refine
Year of publication
- 2006 (330) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (75)
- Fachbereich Bauingenieurwesen (51)
- Fachbereich Wirtschaftswissenschaften (45)
- Fachbereich Luft- und Raumfahrttechnik (32)
- Fachbereich Energietechnik (29)
- Fachbereich Maschinenbau und Mechatronik (29)
- Fachbereich Elektrotechnik und Informationstechnik (27)
- IfB - Institut für Bioengineering (24)
- INB - Institut für Nano- und Biotechnologien (22)
- Fachbereich Chemie und Biotechnologie (17)
Language
- German (166)
- English (160)
- Russian (2)
- Portuguese (1)
- Spanish (1)
Document Type
- Article (180)
- Conference Proceeding (94)
- Book (29)
- Patent (6)
- Part of a Book (5)
- Diploma Thesis (3)
- Lecture (3)
- Other (3)
- Course Material (2)
- Report (2)
Keywords
- Biosensor (23)
- CAD (3)
- Technische Mechanik (3)
- Bauingenieurwesen (2)
- Bauplanung (2)
- Führung (2)
- Leadership (2)
- Motivation (2)
- Rapid Prototyping (2)
- Rapid prototyping (2)
- Self-Leadership (2)
- biosensor (2)
- civil engineering (2)
- 3-nitrofluoranthene (1)
- 3D (1)
- ACCESS 2003 (1)
- ACCESS <Programm> (1)
- Aachen / Fachhochschule Aachen (1)
- Aachen / Fachhochschule Aachen / Fachbereich Bauingenieurwesen (1)
- Aachen University of Applied Sciences (1)
- Absolvententreffen (1)
- Abwasser (1)
- Access (1)
- Actor (1)
- Alfha.net (1)
- Alumni (1)
- Anlagenwirtschaft (1)
- Asteroid Deflection (1)
- AutoCAD (1)
- AutoCAD 2005 (1)
- BTEX compounds (1)
- Bauführung (1)
- Bauherrenvertretung (1)
- Bauleitung (1)
- Baurevision (1)
- Berufsperspektiven (1)
- Biosensorik (1)
- Bruchmechanik (1)
- CO (1)
- Charakter (1)
- Conducing polymer (1)
- Deutsche Bahn Netz AG (1)
- Drahtgittermodell (1)
- ECT (1)
- EPN (1)
- Elastostatics (1)
- Erik (1)
- Evaluation (1)
- Fachhochschule Aachen (1)
- Finite-Elemente-Methode (1)
- Fluorescence (1)
- Fontlab (1)
- Forum Typografie (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Gefühl (1)
- Generative Fertigungstechnik (1)
- Gesichtsausdruck (1)
- Gesichtsmodellierung (1)
- Gesichtsmuskel (1)
- Gewässerausbau (1)
- Gunn diode (1)
- Hand-on-training (1)
- Harlekin (1)
- Hauptbahnhof Aachen (1)
- Hausanschluss (1)
- Heavy metal detection (1)
- High throughput experimentation (1)
- Hochdruckleitung (1)
- Hochschuldidaktik (1)
- Hochwasserschutz (1)
- Hotplate (1)
- Hydrogen sensor (1)
- I3S 2005 (1)
- ISFET (1)
- Ingenieurbau (1)
- International Symposium on Sensor Science (1)
- Kanalbetrieb (1)
- Kanalnetz (1)
- Karosseriebau (1)
- Kinematics (1)
- Kinetics (1)
- Konstruktiver Ingenieurbau (1)
- LED chip (1)
- Leitungsbau (1)
- Leitungsbauunternehmen (1)
- Level sensor (1)
- Lightweight car body construction (1)
- MEMS ; education and training foundry (1)
- Main sensitivity (1)
- Mechanics (1)
- Mentorenprogramm (1)
- Microreactors (1)
- Mimik (1)
- Modellierung (1)
- N-A-Modelle (1)
- Nanoparticles (1)
- Nanostructuring (1)
- Niederschlag-Abfluss-Modelle (1)
- Open Type (1)
- Organophosphorus (1)
- Ostazine Orange (1)
- PFM (1)
- PIMS (1)
- Phenylalanine determination (1)
- Pipeline Integrity Management System (1)
- Planetary Protection (1)
- Potentiometry (1)
- Pseudomonas putida (1)
- Quartz crystal nanobalance (QCN) (1)
- Quartz micro balances (1)
- Rapid Manufacturing (1)
- Rapid Technologie (1)
- Reaction-diffusion (1)
- Relationale Datenbank (1)
- Schrift (1)
- Schriftentwurf (1)
- Schriftkunst (1)
- Solar Sail (1)
- Solid amalgam electrodes (1)
- Spiekermann (1)
- Stahlblech-Leichtmetall Verbundguss (1)
- Stahlblech-Leichtmetall-Hybride (1)
- Statics (1)
- Statiker (1)
- Stereolithographie (1)
- Technologietransfer (1)
- Telekommunikationsmarkt (1)
- Tin oxide (1)
- Trajectory Optimization (1)
- Tunnelbau (1)
- Typographie (1)
- Umbauplanung (1)
- Verbundguss (1)
- Verkehrsbau (1)
- Virtual Technology Lab (1)
- Virtuelles Labor (1)
- Virtuelles Laboratorium (1)
- Wafer (1)
- actor (1)
- ammonia gas sensors (1)
- amperometric sensor (1)
- antimony doped tin oxide (1)
- capillary micro-droplet cell (1)
- carcinogens (1)
- catalytic decomposition (1)
- character (1)
- chemical reduction method (1)
- cross sensitivity (1)
- doped metal oxide (1)
- doped silicon (1)
- doping (1)
- electrical capacitance tomography (1)
- electro-migration (1)
- electronic noses dendronized polymers inverted mesa technology (1)
- enzymatic methods (1)
- enzyme immobilisation (1)
- facial expression (1)
- facial modeling (1)
- fenitrothion (1)
- fluidic (1)
- font (1)
- fontlab (1)
- gas sensor (1)
- gas sensor array (1)
- heater metallisation (1)
- high-temperature stability (1)
- humidity (1)
- hydrogen peroxide (1)
- image sensor (1)
- imaging (1)
- impedance spectroscopy (1)
- ion-selective electrodes (1)
- lab-on-a-chip (1)
- lab-on-chip (1)
- layer expansion (1)
- lenslet array (1)
- magnetic particles (1)
- matrix method (1)
- metal oxide (1)
- microreactor (1)
- microwave generation (1)
- modeling biosensor (1)
- modelling (1)
- modified electrode (1)
- multi-interface measurement (1)
- nitrogen oxides (1)
- open type (1)
- organic PVC membranes (1)
- pH-based biosensing (1)
- pattern-size reduction (1)
- polymer composites (1)
- porous Pt electrode (1)
- principal component (1)
- probabilistic fracture mechanics (1)
- quantum charging (1)
- rapid manufacturing (1)
- screen-printing (1)
- self-aligned patterning (1)
- sensing properties (1)
- sterilisation (1)
- surface modification (1)
- swift heavy ions (1)
- technology diffusion (1)
- technology transfer (1)
- thick-film technology (1)
- thin-film microsensors (1)
- typedesign (1)
- voltammetry (1)
- wafer-level testing (1)
- wire frame model (1)
- Öffentlich bestellter Sachverständiger (1)
Kalkulation
(2006)
In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD+, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results obtained by the spectrophotometric method were compared with the results obtained by the colourimetry, using pH indicators. The above-mentioned two methods will be used as references for potentiometric measurements of phenylalanine concentration.
In this paper, methods of surface modification of different supports, i.e. glass and polymeric beads for enzyme immobilisation are described. The developed method of enzyme immobilisation is based on Schiff’s base formation between the amino groups on the enzyme surface and the aldehyde groups on the chemically modified surface of the supports. The surface of silicon modified by APTS and GOPS with immobilised enzyme was characterised by atomic force microscopy (AFM), time-of-flight secondary ion mass spectroscopy (ToF-SIMS) and infrared spectroscopy (FTIR). The supports with immobilised enzyme (urease) were also tested in combination with microreactors fabricated in silicon and Perspex, operating in a flow-through system. For microreactors filled with urease immobilised on glass beads (Sigma) and on polymeric beads (PAN), a very high and stable signal (pH change) was obtained. The developed method of urease immobilisation can be stated to be very effective.
Die Erfindung betrifft einen elektromagnetischen Aktuator zur Betätigung eines Stellgliedes (7) mit wenigstens einem gesteuert bestrombaren Elektromagneten (1, 2) und einem mit dem Stellglied (7) in Wirkverbindung stehenden Anker (5), der bei Bestromung des Elektromagneten (1, 2) gegen die Kraft wenigstens einer an einem Gehäuse (12) abgestützten Rückstellfeder (10) an der Polfläche (3, 4) des Elektromagneten (1, 2) zur Anlage kommt, und daß zumindest der Anker (5) über eine sphärische Gelenkanordnung (11) auf der Rückstellfeder (10) abgestützt ist.
A new and simple method for nanostructuring using conventional photolithography and layer expansion or pattern-size reduction technique is presented, which can further be applied for the fabrication of different nanostructures and nano-devices. The method is based on the conversion of a photolithographically patterned metal layer to a metal-oxide mask with improved pattern-size resolution using thermal oxidation. With this technique, the pattern size can be scaled down to several nanometer dimensions. The proposed method is experimentally demonstrated by preparing nanostructures with different configurations and layouts, like circles, rectangles, trapezoids, “fluidic-channel”-, “cantilever”- and meander-type structures.
In: Alfha.net / Sektion Bauingenieurwesen: 1. [Erster] Erfahrungsaustausch : Absolventen des Fachbereichs Bauingenieurwesens berichten. 13. Oktober 2006. S. 19-20. Zusammenfassung des Vortrags: Prozessanalyse und Revision beim Umbau des Flughafens Hamburg, Beratung von Bauunternehmen, Sachverständigentätigkeit
Functional testing and characterisation of ISFETs on wafer level by means of a micro-droplet cell
(2006)
A wafer-level functionality testing and characterisation system for ISFETs (ionsensitive field-effect transistor) is realised by means of integration of a specifically designed capillary electrochemical micro-droplet cell into a commercial wafer prober-station. The developed system allows the identification and selection of “good” ISFETs at the earliest stage and to avoid expensive bonding, encapsulation and packaging processes for nonfunctioning ISFETs and thus, to decrease costs, which are wasted for bad dies. The developed system is also feasible for wafer-level characterisation of ISFETs in terms of sensitivity, hysteresis and response time. Additionally, the system might be also utilised for wafer-level testing of further electrochemical sensors.
A concept for a sensitive micro total analysis system for high throughput fluorescence imaging
(2006)
This paper discusses possible methods for on-chip fluorescent imaging for integrated bio-sensors. The integration of optical and electro-optical accessories, according to suggested methods, can improve the performance of fluorescence imaging. It can boost the signal to background ratio by a few orders of magnitudes in comparison to conventional discrete setups. The methods that are present in this paper are oriented towards building reproducible arrays for high-throughput micro total analysis systems (µTAS). The first method relates to side illumination of the fluorescent material placed into microcompartments of the lab-on-chip. Its significance is in high utilization of excitation energy for low concentration of fluorescent material. The utilization of a transparent µLED chip, for the second method, allows the placement of the excitation light sources on the same optical axis with emission detector, such that the excitation and emission rays are directed controversly. The third method presents a spatial filtering of the excitation background.
Mobile Unternehmenssoftware
(2006)
Die Erfindung betrifft eine Vorrichtung zur Messung biomedizinischer Daten eines Probanden, mit einem Messsystem zur Erhebung der Daten sowie einer ersten Hardware-Komponente zur Aufzeichnung der Daten. In einer Verbindungsleitung zur Übertragung der Daten vom Messsystem zur ersten Hardware-Komponente zur Aufzeichnung der Daten ist erfindungsgemäss ein Mittel zur galvanischen Auftrennung der Daten angeordnet. Auf diese Weise ist wenigstens die Duplizierung der Daten für Datenverarbeitungszwecke gewährleistet. Die auf diese Weise verarbeiteten Daten werden für ein Verfahren zur Echtzeit-Stimulation eines Probanden genutzt.
A solid-state amperometric hydrogen sensor based on a protonated Nafion membrane and catalytic active electrode operating at room temperature was fabricated and tested. Ionic conducting polymer-metal electrode interfaces were prepared chemically by using the impregnation-reduction method. The polymer membrane was impregnated with tetra-ammine platinum chloride hydrate and the metal ions were subsequently reduced by using either sodium tetrahydroborate or potassium tetrahydroborate. The hydrogen sensing characteristics with air as reference gas is reported. The sensors were capable of detecting hydrogen concentrations from 10 ppm to 10% in nitrogen. The response time was in the range of 10-30 s and a stable linear current output was observed. The thin Pt films were characterized by XRD, Infrared Spectroscopy, Optical Microscopy, Atomic Force Microscopy, Scanning Electron Microscopy and EDAX.
Baukosten und Finanzierung
(2006)
Abschlussarbeiten FAQ / FGA
(2006)