Refine
Year of publication
Institute
- Fachbereich Energietechnik (1116) (remove)
Language
- English (589)
- German (524)
- Multiple languages (1)
- Dutch (1)
- Spanish (1)
Document Type
- Article (609)
- Conference Proceeding (259)
- Book (126)
- Part of a Book (84)
- Doctoral Thesis (10)
- Conference: Meeting Abstract (7)
- Report (7)
- Other (4)
- Talk (3)
- Diploma Thesis (2)
Keywords
- Blitzschutz (18)
- Lightning protection (11)
- Earthquake (5)
- Diversity Management (4)
- Energy storage (4)
- Power plants (4)
- Risikomanagement (4)
- Seismic design (4)
- reinforced concrete (4)
- Associated liquids (3)
- Concentrated solar power (3)
- Elektromagnetischer Schutzschild (3)
- Hybrid energy system (3)
- INODIS (3)
- Lightning (3)
- Out-of-plane load (3)
- Risikoabschätzung (3)
- Risk management (3)
- Seismic loading (3)
- Stahlbetonkonstruktion (3)
- earthquakes (3)
- renewable energy (3)
- Adjacent buildings (2)
- Central receiver power plant (2)
- Concentrated systems (2)
- Direkter Blitzschlag (2)
- Diversity (2)
- Electricity generation (2)
- Energierecht (2)
- Engineering Habitus (2)
- Erneuerbare Energien (2)
- Gas turbine (2)
- Gasturbine (2)
- Historical centres (2)
- Human-robot collaboration (2)
- Hybridsystem (2)
- INSYSME (2)
- Induzierte Spannungen (2)
- Innovation Management (2)
- Lightning Protection (2)
- Lightning protection system (2)
- Magnetische Felder (2)
- Masonry infill (2)
- Micro turbine (2)
- Mikrogasturbine (2)
- Organizational Culture (2)
- Regenerative Energieanlagen (2)
- Renewable energy (2)
- Risikoabwägung (2)
- Risk assessment (2)
- Shake table test (2)
- Solar thermal technologies (2)
- Stone masonry (2)
- Tanks (2)
- cyber physical production system (2)
- digital shadow (2)
- electromagnetic shielding (2)
- engineering education (2)
- hybrid system (2)
- industrial facilities (2)
- installations (2)
- lightning protection (2)
- photovoltaic system (2)
- piping (2)
- seismic design (2)
- seismic loading (2)
- wind turbine (2)
- Academia (1)
- Acceptance (1)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Alternative Energiequelle (1)
- Anti-Bias (1)
- Antibias (1)
- Artificial intelligence (1)
- Ausfachungsmauerwerk (1)
- BIM (1)
- Basisisolierung (1)
- Bauwerksüberwachung (1)
- Behaviour factor q (1)
- Bemessung (1)
- Best practice sharing (1)
- Biogas (1)
- Blind prediction competition (1)
- Blitz (1)
- Blitzeinschlag (1)
- Blitzrisiko (1)
- Blitzschlag (1)
- Bloom Taxonomy (1)
- COMSOL Multiphysics (1)
- Camera system (1)
- Capacity Curve (1)
- Cardiovascular MRI (1)
- Central receiver system (1)
- Ceramics (1)
- Change Management (1)
- Change management (1)
- Circular bioeconomy (1)
- Civil engineering (1)
- Cloud passages (1)
- Cognitive assistance system (1)
- Components (1)
- Concentrated solar collector (1)
- Concentrating solar power (1)
- Control optimization (1)
- Corporate Culture (1)
- DAC (1)
- DIN EN 1996 (1)
- DNI forecast (1)
- DNI forecasting (1)
- Decision theory (1)
- Decoupling (1)
- Design Thinking (1)
- Design examples (1)
- Digital leadership (1)
- Digitalization (1)
- Direct lightning strike (1)
- Direct normal irradiance forecast (1)
- District data model (1)
- District energy planning platform (1)
- Diversity management (1)
- Dynamic simulation (1)
- EN 1998-4 (1)
- ESHM20, industrial facilities (1)
- Earthquake Engineering (1)
- Electrochemistry (1)
- Elektrizität (1)
- Elektromagnetische Kopplung (1)
- Emilia-Romagna earthquake (1)
- Emissionshandel (1)
- Emissionsrechtehandel (1)
- Empirical consequence curves (1)
- Empirical fragility functions (1)
- Energiekonzept (1)
- Energietechnik (1)
- Energietechnische Anlage (1)
- Energy (1)
- Energy Systems (1)
- Energy system (1)
- Energy system planning (1)
- Engineering (1)
- Engineering Education (1)
- Erdbeben (1)
- Erdbebeneinwirkung (1)
- Erneuerbares Energiengesetz (1)
- Ethics (1)
- Eurocode 8 (1)
- Fernerkundung (1)
- Feuchtigkeit (1)
- Fracture classification (1)
- Frame structure (1)
- Fresnel power plant (1)
- Future Skills (1)
- Future skills (1)
- Gas (1)
- Gender (1)
- Genetic algorithm (1)
- Germany (1)
- Gesamtwassergehalt (1)
- Global change (1)
- Gust wind response (1)
- Heliostat Field Calibration (1)
- Heliostats (1)
- Higher Education (1)
- Hilbert Room (1)
- Human factors (1)
- Human-centered work design (1)
- Hybridanlage (1)
- Hybridization (1)
- Imaging (1)
- In- plane damage (1)
- In-plane (1)
- In-plane load (1)
- In-plane performance, isolation (1)
- Inclusive work climate (1)
- Industrial facilities (1)
- Industrial units (1)
- Industrieanlagen (1)
- Infill wall design (1)
- Infrarot-Reflexions-Absorptions-Spektroskopie (1)
- Infrarotmesstechnik (1)
- Innovation (1)
- Interaction (1)
- Interculturality (1)
- Interdisciplinarity (1)
- Isolation (1)
- Kalkulation (1)
- Kernenergie (1)
- Key competences (1)
- Kraftwerke (1)
- Leadership (1)
- Left ventriular function (1)
- Lightning Risk (1)
- Linear elastic analysis (1)
- LiveLink for MATLAB (1)
- MIR-Spektroskopie (1)
- MR-stethoscope (1)
- Magnetic field strength (1)
- Magnetic resonance imaging (MRI) (1)
- Masonry partition walls (1)
- Masonry structures (1)
- Mauerwerksbauten (1)
- Mauerwerksgebäude (1)
- Maßstabsgetreues Modell (1)
- Measuring instruments (1)
- Methane (1)
- Mixed integer linear programming (MILP) (1)
- Modern constructions (1)
- Molten salt receiver (1)
- Molten salt receiver system (1)
- Molten salt receiver system, (1)
- Molten salt solar tower (1)
- Momentenverteilung (1)
- Monitoring (1)
- Monte Carlo Tree Search (1)
- Morphing (1)
- Multi-storey (1)
- Neo-Deterministic (1)
- Nowcasting (1)
- Nuclear Applications (1)
- Numerical modelling (1)
- Operators (1)
- Optimization module (1)
- Organizational culture (1)
- Out-of-plane (1)
- Out-of-plane capacity (1)
- Out-of-plane failure (1)
- Out-of-plane strength (1)
- PBEE (1)
- PTC (1)
- Parabolic trough collector (1)
- Perception (1)
- Photovoltaics (1)
- Photovoltaikanlage (1)
- Photovoltaikanlagen (1)
- Piping (1)
- Postulates (1)
- Power conversion systems (1)
- Precast buildings (1)
- Privacy (1)
- Probability distribution mapping (1)
- Process prediction (1)
- Psychological concepts (1)
- Pushover analysis (1)
- PushoverAnalysen (1)
- Pyrometrie (1)
- Quadrocopter (1)
- Quantenkaskadenlaser (1)
- Quantenmechanik (1)
- RC frames (1)
- Rahmentragwirkung (1)
- Reinforced concrete frame (1)
- Renewable energy integration (1)
- Response spectrum (1)
- Responsibility (1)
- Risiko (1)
- Risk (1)
- Risk Assessment (1)
- Risk Management (1)
- Risk assessment ; Insurance (1)
- Schrödingers cat (1)
- Seismic (1)
- Seismic Hazard (1)
- Sensor (1)
- Shoulder (1)
- Silos (1)
- Slab deflection (1)
- Social impact measurement (1)
- Solar concentration (1)
- Solar dish (1)
- Solar irradiance (1)
- Speckle (1)
- Spectral analysis (1)
- Stahlbeton (1)
- Stahlbetonrahmen (1)
- Star design (1)
- Structural design (1)
- Structural health monitoring (1)
- Sustainability (1)
- Sustainable engineering education (1)
- Tank (1)
- Temperaturmessung (1)
- Thermal Energy Storage (1)
- Time-series aggregation (1)
- Transient flux distribution (1)
- Trinitrotol (1)
- Two-phase modelling (1)
- Typical periods (1)
- UAV (1)
- Umwelt (1)
- Umweltzertifikathandel (1)
- Uncertainty analysis (1)
- Unmanned aerial vehicle (1)
- Unreinforced masonry buildings (1)
- Unreinforced masonry walls (1)
- Verdunstungskälte (1)
- Verhaltensbeiwerte (1)
- Versicherung (1)
- Virtuelle Kraftwerke (1)
- Vulnerability Curves (1)
- Wand-Decken-Interaktion (1)
- Wellenausbreitung (1)
- Wind turbulence (1)
- Windenergieanlage (1)
- Windenergieanlagen (1)
- Window opening (1)
- Ziegelmauerwerk (1)
- acoustic pyrometry (1)
- antennas (1)
- arresters (1)
- atmospheric modeling (1)
- behaviour factor q (1)
- best practice (1)
- bio-methane (1)
- body limbs (1)
- bubble column (1)
- bullying (1)
- calculations (1)
- carbon dioxide removal (1)
- cardiac gating (1)
- cardiovascular MR imaging (1)
- change management (1)
- churches (1)
- climate neutrality (1)
- concentrating collector (1)
- conductors (1)
- connection detail (1)
- current distribution (1)
- cyber-physical production system (1)
- deserts (1)
- digital twin (1)
- digitalization (1)
- direct air capture (1)
- dissemination (1)
- distribution grid simulation (1)
- diversity (1)
- diversity management (1)
- down-conductor (1)
- e-mobility (1)
- early warning and response system (1)
- earthquake (1)
- earthquake engineering (1)
- economics (1)
- education (1)
- elastomeric bearing (1)
- electrical circuits (1)
- electrical engineering (1)
- electrocardiogram (1)
- electromagnetic coupling (1)
- electromagnetic shield (1)
- energy concept (1)
- energy transition (1)
- engineering (1)
- environment (1)
- equivalent stiffness (1)
- field simulation (1)
- finite element method (1)
- flue gas components (1)
- fluid structure interaction (1)
- fragility curves (1)
- friction pendulum bearing (1)
- gender and diversity (1)
- granular silo (1)
- high field MR imaging (1)
- high-frequency technology (1)
- human digital shadow (1)
- human factors (1)
- human-machine interface (1)
- hybrid-system (1)
- hypoplasticity (1)
- impulsive effects (1)
- in-plane (1)
- in-plane and out-of-plane failure (1)
- in-plane behaviour (1)
- induced voltage (1)
- induced voltages (1)
- innovation (1)
- innovation management (1)
- integration SHM in BIM (1)
- interconnected sensor systems (1)
- internet of production (1)
- lessons learned (1)
- lightning (1)
- lightning flash (1)
- lightning strike (1)
- linear elastic analysis; (1)
- liquid storage tank (1)
- liquid-storage tank (1)
- liquid-structure interaction (1)
- lizards (1)
- macro-element (1)
- magnetic field (1)
- magnetic fields (1)
- magnetic resonance imaging (1)
- masonry infill (1)
- masonry structures (1)
- metal façade (1)
- methanation (1)
- microwave technology (1)
- modern constructions (1)
- negative emissions (1)
- nonlinear transient analyses (1)
- open educational resources (1)
- out-of-plane (1)
- out-of-plane behaviour (1)
- overvoltages (1)
- phonocardiogram (1)
- planning (1)
- plasma technology (1)
- plug flow reactor (1)
- point-focussing system (1)
- policy recommendations (1)
- power generation (1)
- power transmission lines (1)
- power-to-gas (1)
- probability distribution (1)
- protection measures (1)
- raytracing (1)
- recommendations for actions (1)
- renewable energies (1)
- research association (1)
- risk assessment (1)
- risk management (1)
- rollout (1)
- safety control (1)
- scaled model (1)
- seismic (1)
- seismic hazard (1)
- seismic isolation (1)
- seismic response (1)
- seismic risk (1)
- seismic structural damage detection via SHM (1)
- seismic vulnerability (1)
- simplified approach (1)
- smart-charging (1)
- social responsible engineering (1)
- solar process heat (1)
- standards (1)
- steam production (1)
- steel columns (1)
- storage dispatch (1)
- storage optimisation (1)
- structure-soil-structure interaction (1)
- surges (1)
- swimming (1)
- teaching (1)
- temperature measurement (1)
- thermal storage (1)
- touch voltage (1)
- truss (1)
- unreinforced masonry buildings (1)
- user & usage (1)
- vault (1)
- vocal fold oscillation (1)
- wave propagation (1)
- Überspannung (1)
Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT’s performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)%). Conclusions: ACT’s intrinsic insensitivity to interference from electromagnetic fields renders
8. VDE/ABB-Blitzschutztagung, 29. - 30. Oktober 2009 in Neu-Ulm. Blitzschutztagung <8, 2009, Neu-Ulm> Berlin : VDE Verl. 2009 Großkraftwerke können durch Blitzentladungen mit potentiellen Auswirkungen auf deren Verfügbarkeit und Sicherheit gefährdet werden. Ein sehr spezielles Szenario, welches aus aktuellem Anlass zu untersuchen war, betrifft den kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung am Netzanschluss der Anlage. Wird nun noch ein sogenannter Schirmfehler unterstellt, d.h. der direkte Blitzeinschlag erfolgt in ein Leiterseil des Hoch- bzw. Höchstspannungsnetzes und nicht in das darüber gespannte Erdseil, so bedeutet dies eine extreme elektromagnetische Einwirkung. Der vorliegende Beitrag befasst sich mit der Simulation eines solchen Blitzeinschlages und dessen Auswirkungen auf den Netzanschluss und die Komponenten der elektrischen Eigenbedarfsanlagen eines Kraftwerks auf den unterlagerten Spannungsebenen. Die dabei gewonnenen Erkenntnisse lassen sich ohne Einschränkungen auf Industrieanlagen mit Mittelspannungs-Netzanschluss und ohne eigener Stromversorgung übertragen.
Antibias training is increasingly demanded and practiced in academia and industry to increase employees’ sensitivity to discrimination, racism, and diversity. Under the heading of “Diversity Management,” antibias trainings are mainly offered as one-off workshops intending to raise awareness of unconscious biases, create a diversity-affirming corporate culture, promote awareness of the potential of
diversity, and ultimately enable the reflection of diversity in development processes. However, coming from childhood education, research and scientific articles on the sustainable effectiveness of antibias in adulthood, especially in academia, are very scarce. In order to fill this research gap, the article aims to explore how sustainable the effects of individual antibias trainings on participants’ behavior are. In order to investigate this, participant observation in a qualitative pre–post setting was conducted, analyzing antibias training in an academic context. Two observers actively participated in the training sessions and documented the activities and reflection processes of the participants. Overall, the results question the effectiveness of single antibias trainings and show that a target-group adaptive approach is mandatory owing to the background of the approach in early childhood education. Therefore, antibias work needs to be adapted to the target group’s needs and realities of life. Furthermore, the study reveals that single antibias trainings must be embedded in a holistic diversity management approach to stimulate sustainable reflection processes among the target group. This article is one of the first to scientifically evaluate antibias training effectiveness, especially in engineering sciences and the university context.
Extrem hohe Blitzströme
(2017)
Extrem hohe Blitzströme
(2018)
Blitze sind nach wie vor eine enorme Schadensquelle für Personenschäden, Brände, mechanische Zerstörungen und insbesondere auch Überspannungen. Das zeigen nicht zuletzt aktuelle Statistiken der Schadensversicherer. Immer wieder gibt es Meldungen über extrem hohe Blitzströme, die natürlich auch zu großen Schäden und Zerstörungen führen können. Dabei werden Scheitelwerte von teilweise deutlich über 300 kA genannt. Dies wirft Fragen auf, da die „klassische“ Blitzstatistik (z. B. nach CIGRE und IEC [8][10]) bisher solche Werte nicht kennt. Diese extremen Blitzströme werden meist aus den Daten von Blitzortungssystemen ermittelt.
Previous studies optimized the dimensions of coaxial heat exchangers using constant mass fow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar fow types. In contrast, in this study, fow conditions in the circular ring are kept constant (a set of fxed Reynolds numbers) during optimization. This approach ensures fxed fow conditions and prevents inappropriately high or low mass fow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic efort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass fow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellström’s borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefcients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy diference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy fux and hydraulic efort. The Reynolds number in the circular ring is instead of the mass fow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54% of the outer pipe radius for laminar fow and 60% for turbulent fow scenarios. Net-exergetic optimization shows a predominant infuence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth’s thermal properties and the fow type. Conclusively, coaxial geothermal probes’ design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics.
Using optimization to design a renewable energy system has become a computationally demanding task as the high temporal fluctuations of demand and supply arise within the considered time series. The aggregation of typical operation periods has become a popular method to reduce effort. These operation periods are modelled independently and cannot interact in most cases. Consequently, seasonal storage is not reproducible. This inability can lead to a significant error, especially for energy systems with a high share of fluctuating renewable energy. The previous paper, “Time series aggregation for energy system design: Modeling seasonal storage”, has developed a seasonal storage model to address this issue. Simultaneously, the paper “Optimal design of multi-energy systems with seasonal storage” has developed a different approach. This paper aims to review these models and extend the first model. The extension is a mathematical reformulation to decrease the number of variables and constraints. Furthermore, it aims to reduce the calculation time while achieving the same results.
Direct air capture (DAC) combined with subsequent storage (DACCS) is discussed as one promising carbon dioxide removal option. The aim of this paper is to analyse and comparatively classify the resource consumption (land use, renewable energy and water) and costs of possible DAC implementation pathways for Germany. The paths are based on a selected, existing climate neutrality scenario that requires the removal of 20 Mt of carbon dioxide (CO2) per year by DACCS from 2045. The analysis focuses on the so-called “low-temperature” DAC process, which might be more advantageous for Germany than the “high-temperature” one. In four case studies, we examine potential sites in northern, central and southern Germany, thereby using the most suitable renewable energies for electricity and heat generation. We show that the deployment of DAC results in large-scale land use and high energy needs. The land use in the range of 167–353 km2 results mainly from the area required for renewable energy generation. The total electrical energy demand of 14.4 TWh per year, of which 46% is needed to operate heat pumps to supply the heat demand of the DAC process, corresponds to around 1.4% of Germany's envisaged electricity demand in 2045. 20 Mt of water are provided yearly, corresponding to 40% of the city of Cologne‘s water demand (1.1 million inhabitants). The capture of CO2 (DAC) incurs levelised costs of 125–138 EUR per tonne of CO2, whereby the provision of the required energy via photovoltaics in southern Germany represents the lowest value of the four case studies. This does not include the costs associated with balancing its volatility. Taking into account transporting the CO2 via pipeline to the port of Wilhelmshaven, followed by transporting and sequestering the CO2 in geological storage sites in the Norwegian North Sea (DACCS), the levelised costs increase to 161–176 EUR/tCO2. Due to the longer transport distances from southern and central Germany, a northern German site using wind turbines would be the most favourable.
Aufbau von Handelseinheiten
(2012)
In diesem Artikel werden zunächst einleitend der Gasmarkt Deutschland und der sich daraus ergebende Speicherbedarf skizziert. Folgend wird auf verschiedene Speichernutzen aus betriebswirtschaftlicher Perspektive eingegangen und die in diesem Artikel vorgestellten Bewertungsverfahren einleitend beschrieben. In diesem Artikel werden stochastische Optimierungsmethoden aufgegriffen, die sowohl eine Bewertung der Speicher gegenüber einem Spotpreis, als auch gegenüber einer gesamten Forwardcurve ermöglichen. Hierzu werden zunächst Modelle zur Beschreibung der Marktpreise vorgestellt und anhand empirischer Daten kalibriert. Dann wird eine beispielhafte Speicherscheibe zunächst auf Basis der LeastSquareMonteCarloTechnik gegenüber dem stochastischen mehrfaktoriellen Spotpreismodell bewertet. Hieran schließt sich die Vorstellung der Bewertung sowie des Hedgings gegenüber der Forwardcurve an. Abschließend erfolgt eine vergleichende Gegenüberstellung beider Verfahren.
Speicheroptimierung
(2011)
In dieser Lektion wurden beginnend mit der Darstellung des fundamentalen Wandels
des Gasmarktes die daraus folgenden Implikationen für die Einsatzweise von
Gasspeichern abgeleitet. Anschließend wurden zwei Bewertungs- und Steuerungsverfahren für einen Gasspeicher an den beiden Marktstufen Termin- und Spotmarkt methodisch vorgestellt und anhand von Beispielrechnungen illustriert.
Das Verfahren zur Bewertung und Steuerung im Terminmarkt stellt ein sehr
robustes und methodisch einfaches Verfahren dar. Hierbei wird die Saisonalität
der Forwardkurve bzw. deren Veränderungen arbitragefrei mithilfe des Speichers
ausgenutzt. Dieses Verfahren kann nicht den gesamten Zeitwert des Speichers
ausweisen. Es zieht in jedem Zeitpunkt nur die aktuellen Informationen der Forwardkurve zur Entscheidung heran. Es bildet aber keine bedingte Erwartung über
zukünftige Erträge und deren Beeinflussung durch die aktuelle Speicherfahrweise,
um hieraus eine optimale Entscheidung zu formulieren.
Bei der Bewertung gegenüber dem Spotmarkt mithilfe der Least-Squares-Monte-
Carlo-Simulation wird in einer stochastischen Optimierung dagegen der volle Zeitwert des Speichers und damit der gesamte Zusatznutzen der Flexibilität ermittelt. Hierdurch leiten sich auch wesentlich andere Hedging-Empfehlungen als im ersten Verfahren ab, um diesen zu sichern. Der Einsatz der beiden Verfahren im Alltag zur Bewirtschaftung des Speichers hängt insbesondere vom Know-how, den Speicherparametern und der Risikobereitschaft des Handels ab. Beide Strategien liefern hierzu Hedging-Empfehlungen ab, mit welchem der zugrunde liegende Wert gesichert werden kann. Risikoaverse Händler, die einen Großteil des inneren Wertes sichern wollen, könnten im Terminmarkt einen Großteil des Speichers mithilfe des „Intrinsic Rolling“-Verfahrens bewirtschaften. Sie würden hierdurch den saisonalen Spread in der Forwardkurve rollierend sichern. Gleichzeitig kann ein kleinerer Anteil mithilfe der stochastischen Optimierung und den damit verbundenen Ausübungsgrenzen gegenüber dem Spotmarkt bewirtschaftet werden.
In einem liquiden vollständigen Markt wird eine Steuerung des Speichers allein
gegenüber den vorhandenen Marktstufen vorgenommen und der Wert für alle
Marktteilnehmer objektiv messbar. Für den Fall, dass der Markt illiquide ist und
hierdurch z. B. eine Kundenlast nicht allein am Termin- und Spotmarkt jederzeit
gedeckt werden kann, erscheint es notwendig, den Speicher im Kontext einer Portfoliooptimierung zu bewerten. Dies wird in der nächsten Lektion vorgenommen.
Hierbei ist aber zu beachten, dass der Speicher dadurch eine individualisierte Wertkomponente erhält, die von der konkreten Ausgestaltung des jeweiligen Portfolios abhängt.
Risiken des Handels
(2012)
Die Energiewirtschaft befindet sich in einem starken Wandel, der v. a. durch die Energiewende und Digitalisierung Druck auf sämtliche Marktteilnehmer ausübt. Das klassische Geschäftsmodell des Energieversorgungsunternehmens verändert sich dabei grundlegend. Der kontinuierlich ansteigende Einsatz dezentraler und volatiler Erzeugungsanlagen macht die Identifikation von Flexibilitätspotenzialen notwendig, um weiterhin eine hohe Versorgungssicherheit zu gewährleisten. Dieser Schritt ist nur mit einem hohen Digitalisierungsgrad möglich. Eine funktionale Plattform mit Microservices, die zu Geschäftsprozessen verbunden werden können, wird als Möglichkeit zur Aktivierung der Flexibilität und Digitalisierung der Energieversorgungsunternehmen im Folgenden vorgestellt.
Lightning safety guidelines
(2010)
This paper introduces lightning to the layman, noting the right behaviour in front of thunderstorms as well as protective measures against lightning. It also contributes to the prevention of lightning injuries and damages. This report was prepared by the authors inside the AHG1 Group for IEC TC81 (Lightning Protection).
Next Generation Manufacturing promises significant improvements in performance, productivity, and value creation. In addition to the desired and projected improvements regarding the planning, production, and usage cycles of products, this digital transformation will have a huge impact on work, workers, and workplace design. Given the high uncertainty in the likelihood of occurrence and the technical, economic, and societal impacts of these changes, we conducted a technology foresight study, in the form of a real-time Delphi analysis, to derive reliable future scenarios featuring the next generation of manufacturing systems. This chapter presents the organization dimension and describes each projection in detail, offering current case study examples and discussing related research, as well as implications for policy makers and firms. Specifically, we highlight seven areas in which the digital transformation of production will change how we work, how we organize the work within a company, how we evaluate these changes, and how employment and labor rights will be affected across company boundaries. The experts are unsure whether the use of collaborative robots in factories will replace traditional robots by 2030. They believe that the use of hybrid intelligence will supplement human decision-making processes in production environments. Furthermore, they predict that artificial intelligence will lead to changes in management processes, leadership, and the elimination of hierarchies. However, to ensure that social and normative aspects are incorporated into the AI algorithms, restricting measurement of individual performance will be necessary. Additionally, AI-based decision support can significantly contribute toward new, socially accepted modes of leadership. Finally, the experts believe that there will be a reduction in the workforce by the year 2030.