Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1934)
- Fachbereich Elektrotechnik und Informationstechnik (1150)
- Fachbereich Wirtschaftswissenschaften (1121)
- Fachbereich Energietechnik (1067)
- Fachbereich Chemie und Biotechnologie (897)
- Fachbereich Maschinenbau und Mechatronik (812)
- Fachbereich Luft- und Raumfahrttechnik (769)
- Fachbereich Bauingenieurwesen (664)
- IfB - Institut für Bioengineering (627)
- INB - Institut für Nano- und Biotechnologien (586)
Has Fulltext
- no (9330) (remove)
Language
Document Type
- Article (5531)
- Conference Proceeding (1421)
- Book (1062)
- Part of a Book (567)
- Patent (177)
- Bachelor Thesis (169)
- Report (83)
- Doctoral Thesis (82)
- Conference: Meeting Abstract (76)
- Other (67)
Keywords
- Illustration (10)
- Nachhaltigkeit (10)
- Corporate Design (9)
- Erscheinungsbild (8)
- Gamification (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Deutschland (6)
- Digitalisierung (6)
Analog anzeigende Digitaluhr
(1983)
Multiplikativ oder additiv? Diskussionsbeitrag zu Preisanpassungsklauseln in der Gaswirtschaft
(1985)
Steuerreformgesetz 1990
(1989)
Steuerreformgesetz 1990
(1989)
Effektivzins und APR
(1991)
Persistent infection with the high-risk Human Papillomavirus type 16 (HPV 16) is the causative event for the development of cervical cancer and other malignant tumors of the anogenital tract and of the head and neck. Despite many attempts to develop therapeutic vaccines no candidate has entered late clinical trials. An interesting approach is a DNA based vaccine encompassing the nucleotide sequence of the E6 and E7 viral oncoproteins. Because both proteins are consistently expressed in HPV infected cells they represent excellent targets for immune therapy. Here we report the development of 8 DNA vaccine candidates consisting of differently rearranged HPV-16 E6 and E7 sequences within one molecule providing all naturally occurring epitopes but supposedly lacking transforming activity. The HPV sequences were fused to the J-domain and the SV40 enhancer in order to increase immune responses. We demonstrate that one out of the 8 vaccine candidates induces very strong cellular E6- and E7- specific cellular immune responses in mice and, as shown in regression experiments, efficiently controls growth of HPV 16 positive syngeneic tumors. This data demonstrates the potential of this vaccine candidate to control persistent HPV 16 infection that may lead to malignant disease. It also suggests that different sequence rearrangements influence the immunogenecity by an as yet unknown mechanism.
Detecting synchronization clusters in multivariate time series via coarse-graining of Markov chains
(2007)
In this paper research activities developed within the FutureCom project are presented. The project, funded by the European Metrology Programme for Innovation and Research (EMPIR), aims at evaluating and characterizing: (i) active devices, (ii) signal- and power integrity of field programmable gate array (FPGA) circuits, (iii) operational performance of electronic circuits in real-world and harsh environments (e.g. below and above ambient temperatures and at different levels of humidity), (iv) passive inter-modulation (PIM) in communication systems considering different values of temperature and humidity corresponding to the typical operating conditions that we can experience in real-world scenarios. An overview of the FutureCom project is provided here, then the research activities are described.
In this work, we present a compact, bifunctional chip-based sensor setup that measures the temperature and electrical conductivity of water samples, including specimens from rivers and channels, aquaculture, and the Atlantic Ocean. For conductivity measurements, we utilize the impedance amplitude recorded via interdigitated electrode structures at a single triggering frequency. The results are well in line with data obtained using a calibrated reference instrument. The new setup holds for conductivity values spanning almost two orders of magnitude (river versus ocean water) without the need for equivalent circuit modelling. Temperature measurements were performed in four-point geometry with an on-chip platinum RTD (resistance temperature detector) in the temperature range between 2 °C and 40 °C, showing no hysteresis effects between warming and cooling cycles. Although the meander was not shielded against the liquid, the temperature calibration provided equivalent results to low conductive Milli-Q and highly conductive ocean water. The sensor is therefore suitable for inline and online monitoring purposes in recirculating aquaculture systems.
RGB-D sensors such as the Microsoft Kinect or the Asus Xtion are inexpensive 3D sensors. A depth image is computed by calculating the distortion of a known infrared light (IR) pattern which is projected into the scene. While these sensors are great devices they have some limitations. The distance they can measure is limited and they suffer from reflection problems on transparent, shiny, or very matte and absorbing objects. If more than one RGB-D camera is used the IR patterns interfere with each other. This results in a massive loss of depth information. In this paper, we present a simple and powerful method to overcome these problems. We propose a stereo RGB-D camera system which uses the pros of RGB-D cameras and combine them with the pros of stereo camera systems. The idea is to utilize the IR images of each two sensors as a stereo pair to generate a depth map. The IR patterns emitted by IR projectors are exploited here to enhance the dense stereo matching even if the observed objects or surfaces are texture-less or transparent. The resulting disparity map is then fused with the depth map offered by the RGB-D sensor to fill the regions and the holes that appear because of interference, or due to transparent or reflective objects. Our results show that the density of depth information is increased especially for transparent, shiny or matte objects.
Clinical assessment of newly developed sensors is important for ensuring their validity. Comparing recordings of emerging electrocardiography (ECG) systems to a reference ECG system requires accurate synchronization of data from both devices. Current methods can be inefficient and prone to errors. To address this issue, three algorithms are presented to synchronize two ECG time series from different recording systems: Binned R-peak Correlation, R-R Interval Correlation, and Average R-peak Distance. These algorithms reduce ECG data to their cyclic features, mitigating inefficiencies and minimizing discrepancies between different recording systems. We evaluate the performance of these algorithms using high-quality data and then assess their robustness after manipulating the R-peaks. Our results show that R-R Interval Correlation was the most efficient, whereas the Average R-peak Distance and Binned R-peak Correlation were more robust against noisy data.