Refine
Year of publication
- 2023 (260) (remove)
Institute
- Fachbereich Gestaltung (95)
- Fachbereich Medizintechnik und Technomathematik (40)
- Fachbereich Elektrotechnik und Informationstechnik (29)
- ECSM European Center for Sustainable Mobility (24)
- Fachbereich Luft- und Raumfahrttechnik (24)
- Fachbereich Wirtschaftswissenschaften (21)
- Fachbereich Chemie und Biotechnologie (18)
- Fachbereich Energietechnik (14)
- Fachbereich Maschinenbau und Mechatronik (12)
- INB - Institut für Nano- und Biotechnologien (12)
- IfB - Institut für Bioengineering (9)
- Nowum-Energy (7)
- Fachbereich Bauingenieurwesen (6)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (6)
- Kommission für Forschung und Entwicklung (4)
- Fachbereich Architektur (3)
- Institut fuer Angewandte Polymerchemie (3)
- Solar-Institut Jülich (3)
- FH Aachen (2)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
- Kommission für Planung und Finanzen (1)
- Senat (1)
Document Type
- Bachelor Thesis (93)
- Article (79)
- Conference Proceeding (37)
- Part of a Book (23)
- Book (11)
- Patent (3)
- Habilitation (2)
- Master's Thesis (2)
- Preprint (2)
- Talk (2)
Keywords
- Corporate Design (6)
- Editorial (6)
- Illustration (6)
- Typografie (6)
- Nachhaltigkeit (5)
- Produktdesign (5)
- Fotografie (4)
- Publikation (4)
- Design (3)
- Erscheinungsbild (3)
Zugriffsart
- weltweit (100)
- campus (47)
- bezahl (32)
- fachbereichsweit (FB4) (12)
In this paper, we provide an analytical study of the transmission eigenvalue problem with two conductivity parameters. We will assume that the underlying physical model is given by the scattering of a plane wave for an isotropic scatterer. In previous studies, this eigenvalue problem was analyzed with one conductive boundary parameter whereas we will consider the case of two parameters. We prove the existence and discreteness of the transmission eigenvalues as well as study the dependence on the physical parameters. We are able to prove monotonicity of the first transmission eigenvalue with respect to the parameters and consider the limiting procedure as the second boundary parameter vanishes. Lastly, we provide extensive numerical experiments to validate the theoretical work.
This paper presents an approach for reducing the cognitive load for humans working in quality control (QC) for production processes that adhere to the 6σ -methodology. While 100% QC requires every part to be inspected, this task can be reduced when a human-in-the-loop QC process gets supported by an anomaly detection system that only presents those parts for manual inspection that have a significant likelihood of being defective. This approach shows good results when applied to image-based QC for metal textile products.
Existing residential buildings have an average lifetime of 100 years. Many of these buildings will exist for at least another 50 years. To increase the efficiency of these buildings while keeping costs at reasonable rates, they can be retrofitted with sensors that deliver information to central control units for heating, ventilation and electricity. This retrofitting process should happen with minimal intervention into existing infrastructure and requires new approaches for sensor design and data transmission. At FH Aachen University of Applied Sciences, students of different disciplines work together to learn how to design, build, deploy and operate such sensors. The presented teaching project already created a low power design for a combined CO2, temperature and humidity measurement device that can be easily integrated into most home automation systems
Background
Hip fractures are a common and costly health problem, resulting in significant morbidity and mortality, as well as high costs for healthcare systems, especially for the elderly. Implementing surgical preventive strategies has the potential to improve the quality of life and reduce the burden on healthcare resources, particularly in the long term. However, there are currently limited guidelines for standardizing hip fracture prophylaxis practices.
Methods
This study used a cost-effectiveness analysis with a finite-state Markov model and cohort simulation to evaluate the primary and secondary surgical prevention of hip fractures in the elderly. Patients aged 60 to 90 years were simulated in two different models (A and B) to assess prevention at different levels. Model A assumed prophylaxis was performed during the fracture operation on the contralateral side, while Model B included individuals with high fracture risk factors. Costs were obtained from the Centers for Medicare & Medicaid Services, and transition probabilities and health state utilities were derived from available literature. The baseline assumption was a 10% reduction in fracture risk after prophylaxis. A sensitivity analysis was also conducted to assess the reliability and variability of the results.
Results
With a 10% fracture risk reduction, model A costs between $8,850 and $46,940 per quality-adjusted life-year ($/QALY). Additionally, it proved most cost-effective in the age range between 61 and 81 years. The sensitivity analysis established that a reduction of ≥ 2.8% is needed for prophylaxis to be definitely cost-effective. The cost-effectiveness at the secondary prevention level was most sensitive to the cost of the contralateral side’s prophylaxis, the patient’s age, and fracture treatment cost. For high-risk patients with no fracture history, the cost-effectiveness of a preventive strategy depends on their risk profile. In the baseline analysis, the incremental cost-effectiveness ratio at the primary prevention level varied between $11,000/QALY and $74,000/QALY, which is below the defined willingness to pay threshold.
Conclusion
Due to the high cost of hip fracture treatment and its increased morbidity, surgical prophylaxis strategies have demonstrated that they can significantly relieve the healthcare system. Various key assumptions facilitated the modeling, allowing for adequate room for uncertainty. Further research is needed to evaluate health-state-associated risks.
Clinical assessment of newly developed sensors is important for ensuring their validity. Comparing recordings of emerging electrocardiography (ECG) systems to a reference ECG system requires accurate synchronization of data from both devices. Current methods can be inefficient and prone to errors. To address this issue, three algorithms are presented to synchronize two ECG time series from different recording systems: Binned R-peak Correlation, R-R Interval Correlation, and Average R-peak Distance. These algorithms reduce ECG data to their cyclic features, mitigating inefficiencies and minimizing discrepancies between different recording systems. We evaluate the performance of these algorithms using high-quality data and then assess their robustness after manipulating the R-peaks. Our results show that R-R Interval Correlation was the most efficient, whereas the Average R-peak Distance and Binned R-peak Correlation were more robust against noisy data.
Kinder sind bei der Suche nach Antworten auf ihre Fragen in unserer medialen Gesellschaft stark mit dem digitalen Raum konfrontiert. Diese Medien können bei einer nicht kindergerechten Benutzung wichtige Entwicklungsprozesse hindern. Im Gegensatz dazu geben diese aber auch die Möglichkeit, Kindern wichtige Denkgewohnheiten beizubringen und sie besser auf die Zukunft vorzubereiten. Ziel der Arbeit ist es, eine Verbindung zwischen der analogen und digitalen Welt herzustellen und ein vielfältiges Lernen zu ermöglichen. Die App „miela“ schafft eine neue Ebene der Wissensvermittlung durch die Kombination von digitaler und analoger Welt. Das Userinterface ist altersentsprechend gestaltet und bietet unterschiedliche Themenfelder an, wobei die Wissensvermittlung und die Kreativität im Fokus stehen. Eine Zusammenarbeit mit der Toniebox als digitale Erweiterung kann weitere Themenfelder anbieten.
With the prevalence of glucosamine- and chondroitin-containing dietary supplements for people with osteoarthritis in the marketplace, it is important to have an accurate and reproducible analytical method for the quantitation of these compounds in finished products. NMR spectroscopic method based both on low- (80 MHz) and high- (500–600 MHz) field NMR instrumentation was established, compared and validated for the determination of chondroitin sulfate and glucosamine in dietary supplements. The proposed method was applied for analysis of 20 different dietary supplements. In the majority of cases, quantification results obtained on the low-field NMR spectrometer are similar to those obtained with high-field 500–600 MHz NMR devices. Validation results in terms of accuracy, precision, reproducibility, limit of detection and recovery demonstrated that the developed method is fit for purpose for the marketed products. The NMR method was extended to the analysis of methylsulfonylmethane, adulterant maltodextrin, acetate and inorganic ions. Low-field NMR can be a quicker and cheaper alternative to more expensive high-field NMR measurements for quality control of the investigated dietary supplements. High-field NMR instrumentation can be more favorable for samples with complex composition due to better resolution, simultaneously giving the possibility of analysis of inorganic species such as potassium and chloride.
Traditional vulcanization mold manufacturing is complex, costly, and under pressure due to shorter product lifecycles and diverse variations. Additive manufacturing using Fused Filament Fabrication and high-performance polymers like PEEK offer a promising future in this industry. This study assesses the compressive strength of various infill structures (honeycomb, grid, triangle, cubic, and gyroid) when considering two distinct build directions (Z, XY) to enhance PEEK’s economic and resource efficiency in rapid tooling. A comparison with PETG samples shows the behavior of the infill strategies. Additionally, a proof of concept illustrates the application of a PEEK mold in vulcanization. A peak compressive strength of 135.6 MPa was attained in specimens that were 100% solid and subjected to thermal post-treatment. This corresponds to a 20% strength improvement in the Z direction. In terms of time and mechanical properties, the anisotropic grid and isotropic cubic infill have emerged for use in rapid tooling. Furthermore, the study highlights that reducing the layer thickness from 0.15 mm to 0.1 mm can result in a 15% strength increase. The study unveils the successful utilization of a room-temperature FFF-printed PEEK mold in vulcanization injection molding. The parameters and infill strategies identified in this research enable the resource-efficient FFF printing of PEEK without compromising its strength properties. Using PEEK in rapid tooling allows a cost reduction of up to 70% in tool production.
06| Warum es gemeinsam besser geht
10| Interview
14| Wer ist hier der Boss?
18| Schnittstelle zwischen Mensch und Technik
22| Zweite Heimat Jülich
28| Zwischen Angst und Hoffnung
32| Eine Sternstunde für die FH Aachen
36| Gegen alle Widerstände
38| Ein Ort, der bleibt
42| Der Aufblühende
46| Der Computer sitzt am Steuer
52| Da geht das Herz auf
54| Hoch hinaus
58| Beratungsangebote
60| Das alte Schätzchen
§ 1 | Geltungsbereich der Prüfungsordnung
§ 2 | Ziel des Studiums, Zweck der Prüfung, Abschlussgrad
§ 3 | Beginn, Dauer, Umfang und Gliederung des Studiums
§ 4 | Zugang zum Studium, Praktikum
§ 5 | Prüfungsausschuss
§ 6 | Studien- und Prüfungselemente
§ 7 | Zulassung zu den Prüfungen
§ 8 | Durchführung von Prüfungen
§ 9 | Verbesserungsversuch
§ 10 | Anrechnung von Studienzeiten, Studien- und Prüfungsleistungen
§ 11 | Praxissemester
§ 12 | Mobilitätssemester (Auslandssemester)
§ 13 | Bachelorprojekt§ 14 | Gesamtnote, Zeugnis, Bachelorurkunde
§ 15 | Inkrafttreten, Veröffentlichung
Anlage 1 | Studienplan Kernstudium
Anlage 2 | Allgemeine Kompetenzen