Article
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1591)
- Fachbereich Wirtschaftswissenschaften (705)
- Fachbereich Elektrotechnik und Informationstechnik (637)
- Fachbereich Energietechnik (609)
- Fachbereich Chemie und Biotechnologie (602)
- INB - Institut für Nano- und Biotechnologien (542)
- Fachbereich Maschinenbau und Mechatronik (483)
- IfB - Institut für Bioengineering (449)
- Fachbereich Luft- und Raumfahrttechnik (379)
- Fachbereich Bauingenieurwesen (333)
Language
Document Type
- Article (5642) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- Multimediamarkt (6)
- Rapid prototyping (5)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- Rapid Prototyping (4)
- biosensors (4)
Additive Manufacturing durch Aufschmelzen von Metallpulvern hat sich auf breiter Front als Herstellverfahren, auch für Endprodukte, etabliert. Besonders für die Variante des Selective Laser Melting (SLM) sind Anwendungen in der Zahntechnik bereits weit verbreitet und der Einsatz in sensitiven Branchen wie der Luftfahrt ist in greifbare Nähe gerückt. Deshalb werden auch vermehrt Anstrengungen unternommen, um bisher nicht verarbeitete Materialien zu qualifizieren. Dies sind vorzugsweise Nicht-Eisen- und Edelmetalle, die sowohl eine sehr hohe Reflektivität als auch eine sehr gute Wärmeleitfähigkeit aufweisen – beides Eigenschaften, die die Beherrschung des Laser-Schmelzprozesses erschweren und nur kleine Prozessfenster zulassen. Die Arbeitsgruppe SLM des Lehr- und Forschungsgebietes Hochleistungsverfahren der Fertigungstechnik hat sich unter der Randbedingung einer kleinen und mit geringer Laserleistung ausgestatteten SLM Maschine der Aufgabe gewidmet und am Beispiel von Silber die Parameterfelder für Einzelspuren und wenig komplexe Geometrien systematisch untersucht. Die Arbeiten wurden von FEM Simulationen begleitet und durch metallographische Untersuchungen verifiziert. Die Ergebnisse bilden die Grundlage zur schnellen Parameterfindung bei komplexen Geometrien und bei Veränderungen der Zusammensetzung, wie sie bei zukünftigen Legierungen zu erwarten sind. Die Ergebnisse werden exemplarisch auf unterschiedliche Geometrien angewandt und entsprechende Bauteile gezeigt.
Pseudo-dynamische Versuche an Reihenmittelhäusern – Vergleich mit aktuellen Berechnungsansätzen
(2008)
Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free-running ADCs at a sampling rate of 40 MHz. A four-channel acquisition board has been developed which is equipped with four 12-bit ADCs connected to one field programmable gate array (FPGA). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware trigger can be omitted. The method of free-running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. This information is crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows very high count rates to be dealt with. Since this method is to be employed in positron emission tomography (PET), the position of an event is also important. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO scintillators coupled to the PS-PMT are presented here
Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free running ADCs at a sampling rate of 40 MHz. A four-channel acquisition-board has been developed which is equipped with four 12 bit-ADCs connected to one FPGA (field programmable gate array). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware-trigger can be omitted. The method of free running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. These informations are crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows coping with very high count rates. Since this method is going to be employed in positron emission tomography (PET), the position of an event is another important information. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO-scintillators coupled to the PS-PMT are presented
Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET
(2003)
A feasible way to gain the depth of interaction information in a PET scanner is the use of phoswich detectors. In general the layer of interaction is identified front the pulse shape of the corresponding scintillator material. In this work pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could he kept simple due to an additional slow component in the light decay of the LuYAP pulse. At the same time the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time.
Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET
(2003)
A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time.
In traditional microbial biobutanol production, the solvent must be recovered during fermentation process for a sufficient space-time yield. Thermal separation is not feasible due to the boiling point of n-butanol. As an integrated and selective solid-liquid separation alternative, solvent impregnated resins (SIRs) were applied. Two polymeric resins were evaluated and an extractant screening was conducted. Vacuum application with vapor collection in fixed-bed column as bioreactor bypass was successfully implemented as butanol desorption step. In course of further increasing process economics, fermentation with renewable lignocellulosic substrates was conducted using Clostridium acetobutylicum. Utilization of SIR was shown to be a potential strategy for solvent removal from fermentation broth, while application of a bypass column allows for product removal and recovery at once.
As researchers continue to seek the expansion of the material base for additive manufacturing, there is a need to focus attention on the Ni–Cu group of alloys which conventionally has wide industrial applications. In this work, the G-NiCu30Nb casting alloy, a variant of the Monel family of alloys with Nb and high Si content is, for the first time, processed via the laser powder bed fusion process (LPBF). Being novel to the LPBF processes, optimum LPBF parameters were determined, and hardness and tensile tests were performed in as-built conditions and after heat treatment at 1000 °C. Microstructures of the as-cast and the as-built condition were compared. Highly dense samples (99.8% density) were achieved after varying hatch distance (80 µm and 140 µm) with scanning speed (550 mm/s–1500 mm/s). There was no significant difference in microhardness between varied hatch distance print sets. Microhardness of the as-built condition (247 HV0.2) exceeded the as-cast microhardness (179 HV0.2.). Tensile specimens built in vertical (V) and horizontal (H) orientations revealed degrees of anisotropy and were superior to conventionally reported figures. Post heat treatment increased ductility from 20% to 31% (V), as well as from 16% to 25% (H), while ultimate tensile strength (UTS) and yield strength (YS) were considerably reduced.
Qualitaetssicherung in der automatisierten schweisstechnischen Fertigung durch Einsatz von Sensoren
(1983)
Qualitaetssicherung in der automatisierten schweisstechnischen Fertigung durch Einsatz von Sensoren
(1983)
Qualität in die Wiege gelegt
(1987)
Quantitative Farbmessung in laryngoskopischen Bildern. Palm, C; Scholl, I; Lehmann, TM; Spitzer, K.
(1998)
Heparin is a natural polysaccharide, which plays essential role in many biological processes. Alterations in building blocks can modify biological roles of commercial heparin products, due to significant changes in the conformation of the polymer chain. The variability structure of heparin leads to difficulty in quality control using different analytical methods, including infrared (IR) spectroscopy. In this paper molecular modelling of heparin disaccharide subunits was performed using quantum chemistry. The structural and spectral parameters of these disaccharides have been calculated using RHF/6-311G. In addition, over-sulphated chondroitin sulphate disaccharide was studied as one of the most widespread contaminants of heparin. Calculated IR spectra were analyzed with respect to specific structure parameters. IR spectroscopic fingerprint was found to be sensitive to substitution pattern of disaccharide subunits. Vibrational assignments of calculated spectra were correlated with experimental IR spectral bands of native heparin. Chemometrics was used to perform multivariate analysis of simulated spectral data.